10
Command
Function
Feedback Example
50792%
HDCP
™
Manual mode.
HDCP Manual
50793%
Enables HDCP output.
HDCP ON
50794%
Disables HDCP output.
HDCP OFF
50795%
Inquire HDCP / Manual HDCP
HCDP Manual
HDCP ON/OFF
50767%
Restore the default EDID® settings.
EDID: initial
50768%
Bypass EDID data from output to input.
EDID: bypass
50769%
Upload custom EDID data to the device.
EDID: user
50770%
Query the EDID status.
EDID: xxxx (xxxx=initial,
bypass, or user)
50782%
EDID management. Copies the resolution
data of the connected display to the
HDMI® inputs.
EDID manage
Resolution: xx
(xx=1920x1200, 1920x1080,
1600x1200, 1360x768,
1280x720, or 1024x768)
50787%
Enables serial control mode 1: controls the
scaler/s
witch and the HDBaseT™ receiver
from the RS-232 port on the scaler/switch.
RS232 Mode 1: RS232
Control Scaler & Remote
50788%
Enables serial control mode 2: controls the
scaler/switch from the RS-232 port on the
scaler/switch or the one on the HDBaseT
receiver.
RS232 Mode 2: RS232
Control Scaler.
50174%
Auto Switch Mode: Disables the automatic
power off function.
Auto Switch Mode: Set no
input to power off function:
Disable