Black Knight HCPRO 12 CFM Operation Manual Download Page 4

INITIAL PREPARATION

PAG 3

- The Vacuum Pump is shipped without oil in the oil reservoir. Remove the exhaust cap and add oil until it is seen  at the maximum fill point on the oil 

sight glass. Re-secure cap.

- Connect the vacuum pump to the proper power supply.

- With all caps in place, turn on the vacuum pump. Run for 2 minutes to allow for proper lubrication.

- Re-check vacuum pump oil level. Add oil if necessary.

To achieve good ultimate vacuum levels, the oil level should be no lower than the midpoint of the sight glass.

FIGURE 1

A/C SYSTEM EVACUATION PROCESS CHART

OPERATION:

WARNING:  

Do not operate on systems or vessels under pressure.  Damage to the pump may occur.  Pressure of the system or vessel should be at or 

below 0 PSIG (atmospheric pressure).

1. Check and connect to the correct power supply.

2. Check oil level in vacuum pump.

3. Connect vacuum pump pump as shown in Figure 1.

4. Check pressure on manifold set to ensure at or below 0 PSIG.

5. Open manifold valves.

6. Turn Vacuum Pump power switch to ON

7. Run vacuum pump until final vacuuum level is obtained. 

8. Once the final vacuum level is reached, close the manifold valves, turn power switch OFF.

Vacuum Operation is now complete.

Vacuum Pump is now ready for use.

BLDC MOTOR TECHNOLOGY

Summary of Contents for HCPRO 12 CFM

Page 1: ...E LICENSED PLEASE CHECK WITH YOUR LOCAL GOVERNMENT AGENCY HCPRO PRODUCTS Miami Florida 33182 USA Tel 305 888 0286 Email info hcproproducts com www hcproproducts com Designed and engineered in USA PART...

Page 2: ...b normal wear and tear on handling the vacuum pump Ultimate vacuum down to 15 microns Gas Ballast valve Oil Sight Glass for easy viewing of oil level and oil contamination color Please continue to rea...

Page 3: ...rotected ON OFF Power Switch 12 CFM 1 4 SAE 5 16 SAE and 3 8 SAE w Internal Solenoid Valve Shutoff Yes SPECIFICATIONS HANDLE GAS BALLAST VALVE EXHAUST PORT OIL FILL OIL RESERVOUIR OIL SIGHT GLASS OIL...

Page 4: ...FIGURE 1 A C SYSTEM EVACUATION PROCESS CHART OPERATION WARNING Do not operate on systems or vessels under pressure Damage to the pump may occur Pressure of the system or vessel should be at or below 0...

Page 5: ...p oil 1 Run the vacuum pump for 3 5 minutes Open the inlet cap for the last 30 seconds 2 Turn off and unplug the vacuum pump 3 Remove the exhaust cap 4 Place the vacuum pump on a flat table Place a tr...

Page 6: ...warm up the vacuum pump oil to free up the vacuum pump mechanism Try restarting several times to clear out the excessive oil This condition can occur if the vacuum pump is shut down and left in the va...

Page 7: ...FAN BLADE GUARD FAN BLADE OIL RESERVOUR ANALOG VACUUM VACUUM PUMP OIL QUART VACUUM PUMP OIL GALLON PART NUMBER HCBK 12DC 22 0011 HC 12 1 22 0012 HC 12 2 22 0013 HC 12 3 22 0014 HC 12 4 22 0015 HC 12 5...

Page 8: ...SUARIO TENGA LICENCIA LOCAL HCPRO PRODUCTS Miami Florida 33182 USA Tel 305 888 0286 Email info hcproproducts com www hcproproducts com Dise o e Ingenier a en USA PARTE 22 0011 ADVERTENCIA Mantengase f...

Page 9: ...de aceite Base reforzada para absorber el desgaste normal al manipular la bomba de vac o M ximo vac o de hasta 15 micras V lvula de lastre de gas Mirilla para ver f cilmente el nivel de aceite y la co...

Page 10: ...E 5 16 SAE y 3 8 SAE con Cierre de V lvula Solenoide interna Si ESPECIFICACIONES MANGO V LVULA DE LASTRE DE GAS PUERTO DE ESCAPE LLENADO DE ACEITE DEP SITO DE ACEITE MIRILLA DEL ACEITE V LVULA DE DREN...

Page 11: ...EL SISTEMA DE A C OPERACI N ADVERTENCIA No opere en sistemas o recipientes bajo presi n Pueden producirse da os en la bomba La presi n del sistema o recipiente debe ser de 0 PSIG presi n atmosf rica o...

Page 12: ...entrada durante los ltimos 30 segundos 2 Apague y desenchufe la bomba de vac o 3 Retire la tapa de escape 4 Coloque la bomba de vac o en una mesa plana Coloque una bandeja debajo del puerto de drenaje...

Page 13: ...vac o El vac o en la c mara har que el aceite migre y llene la c mara El motor est atascado o bloqueado Bajas temperaturas Con la alimentaci n desconectada retire el medidor del ventilador A ver si e...

Page 14: ...O BASE PROTECTOR DE PALETA DE VENTILADOR PALETA DE VENTILDADOR DEP SITO DE ACEITE VAC O AN LOGO CUARTO DE ACEITE DE BOMBA DE VAC O GAL N DE ACEITE DE BOMBA DE VAC O N MERO DE PARTE HCBK 12DC 22 0011 H...

Page 15: ...CONTACT PAGE NOTES OTHERS EMAIL LIST NOTES PHONE LIST PAG 14 HCPRO PRODUCTS Miami Florida 33182 USA Tel 305 888 0286 Email info hcproproducts com www hcproproducts com...

Reviews: