background image

ETH-FE1

Interface Types

10/100BaseT

Standards Compliance

IEEE 802.3

Connectors

RJ-45 (10/100 BaseT Electrical)

MDI-X

Supported (auto adapts cross-straight cable)

Mode

Autonegotiation (Half/Full - 10/100M) 

Ethernet Port 

S

pecifications

Clock

Encapsulation

Internal (Master) and network (Slave) clock.

HDLC

HDLC mode is required in installation between two VCL-ETH-FE1 
(point to point protocol) if fractional E1 is used to carry payload

GFP

GFP Mode is must, to use the VCL-ETH-FE1 in point to multi point
Protocol with Delux models (VCL-ETH-4/8/16 and VCL-ETH-8/16-ML)

7

Black Iris For Telecom & Technology - 2008

Summary of Contents for ETH-FE1

Page 1: ...echnology Black Iris For Telecom Technology 2008 Black Iris For Telecom Technology 1 Sport City Sarh Alshaheed St Al Gaber 2 Complex Office 308 P O 11947 570 Amman Jordan Phone 962 6 5150369 Fax 962 6 5150630 Mobile 962 77 7411303 Email nayef black iris net Website www Black iris net ...

Page 2: ... bandwidth of telecom operators existingTDM network to transport Ethernet data with low investment The equipment may be used for the following purposes Bridging Ethernet LANs over existingTDM E1 telecom network Extending Ethernet networks utilizingTDM E1 landline based telecom infrastructure Using telecom network of E1s PDH SDH microwave etc carrying E1s to transport Ethernet data VCL ETH FE1 VCL ...

Page 3: ...GFP HDLC PWR LOS E1 LOF RA AIS LINK CV FDX LOOP ERR ETH TEST CONSOLE LAN VCL ETH FE1 RION TELECOM NETWORKS www oriontelecom com OFF ON 5 1 6 2 7 3 8 4 MASTER TEST GFP HDLC PWR LOS E1 LOF RA AIS LINK CV FDX LOOP ERR ETH TEST CONSOLE LAN VCL ETH FE1 RION TELECOM NETWORKS www oriontelecom com OFF ON 5 1 6 2 7 3 8 4 MASTER TEST GFP HDLC PWR LOS E1 LOF RA AIS LINK CV FDX LOOP ERR ETH TEST CONSOLE LAN L...

Page 4: ...k Loop timed clock With multiple loopback functions and built in bit error testing function it facilitates the trouble shooting Compatible to deluxe models VCL ETH 4 8 16 and VCL ETH 8 16 ML and can be installed with them to reduce the installation cost Easy to operate Power supply options 110VAC 240VAC 50 60 Hz power options available 48V DC power option available Power consumption less than 4Wat...

Page 5: ...0M Ethernet Port Specifications Clock Encapsulation Internal Master and network Slave clock HDLC HDLC mode is required in installation between two VCL ETH FE1 point to point protocol if fractional E1 is used to carry payload GFP GFP Mode is must to use the VCL ETH FE1 in point to multi point Protocol with Delux models VCL ETH 4 8 16 and VCL ETH 8 16 ML 7 Black Iris For Telecom Technology 2008 ...

Page 6: ...ter and Ethernet converter have safely grounded BER test may be conducted on each E1 link using a BERTtester to ensure that the E1 errors are within the permitted limits threshold Step 3 Please configure the ethernet mode of the Ethernet over E1 equipment at both sides as well as the ethernet interfaces of the devices that are connected to the Ethernet over E1 equipment Connect the ethernet links ...

Page 7: ...K CV ON Red E1 code violation alarm indication OFF OK LINK ON Green LAN port connection Normal OFF No LAN connection on Ethernet port FDX ON Green Ethernet port is running in full duplex mode OFF Ethernet port is running in half duplex mode LOOP ON Yellow system is in test mode OFF Normal operation mode ERR ON Red Error in BER test E1 Signal OFF BER test OFF or has no errors Switch Status Descript...

Page 8: ...t E1 Port 120W E1 Port 120W Input E1 75W Input E1 75W Output E1 75W Output E1 75W ON OFF Switch ON OFF Switch Tag Description IN 75W Represents the unbalanced E1 75W input BNC OUT 75W Represents the unbalanced E1 75W Output BNC 120W Represents the balanced E1 120W input output RJ 45 ETH Fast Ethernet interface RJ 45 220V Represents AC 220V inlet 48V Represents DC 48V inlet 48V DC Inlet 10 Black Ir...

Page 9: ... toTS5 to ON and time slotTS16 will be set to ON Example 2 If you wish to carry first 8 time slots on 512Kbps then you need to set the TS0 time slot OFF and switch TS1 to TS8 to ON i e since each time slot consumes 64Kbps so 8 time slots will consume 8 x 64Kbps 512Kbps and time slot S16 will be set to ON Example 3 If you wish to carry 20 time slots on 1 28Mbps 64Kbps x 20 then you need to set time...

Page 10: ...gnal Input 8 TX transmitted data RS232 Signal Output Others NC PIN No Definition of function Signal Direction 1 TX transmitted data Data Output 2 TX transmitted data Data Output 3 RX received data Data Input 6 RX received data Data Input Others NC Ethernet RJ 45 Pinouts E1 120W RJ 45 Pinout Details Console RJ 45 Pinout Details 1 Bits per second 19200 2 Data bits 8 3 Parity None 4 Stop bits 1 5 Flo...

Page 11: ...de Auto Negotiation showeth View Ethernet port status showframe View framing status showclock View E1 clock mode showencapmode View encapulation mode setgfp Configure PFI EXI PSCRD and HSCRD of GFP showgfp View PFI EXI PSCRD and HSCRD of GFP For detailed command format please key cmdname or help cmdname VCL cmdname enter OR VCL help cmdname enter Example VCL showe1alarm FORMAT showe1alarm EXPLANAT...

Page 12: ...Speed Mode Auto Negotiation PARAMETER AN 0 1 Autotiation 0 AN not done 1 AN done speed 0 1 0 10Mbit s 1 100Mbit s duplex 0 1 0 half duplex 1 full duplex flow 0 1 flow control capability 0 disable 1 enable Example VCL seteth 1 1 1 1 AN Speed Duplex Flow Auto 100M Full Enable FORMAT showeth EXPLANATION View Ethernet port status PARAMETER none Example VCL showeth AN Speed Duplex Flow Status Not Auto ...

Page 13: ...howclock E1 Clock Master FORAMT showencapmode EXPLANATION View encapsulation mode PARAMETER none Example VCL showencapmode The encapulation mode is HDLC FORMAT setgfp PFI EXI PSCRD HSCRD EXPLANATION Configure PFI EXI PSCRD and HSCRD of GFP PARAMETER PFI 0 1 EXI 0 15 PSCRD 1 enable 0 disable HSCRD 1 enable 0 disable Example VCL setgfp 0 0 1 1 PFI 0 EXI 0 PSCRD Enable HSCRD Enable 15 Black Iris For ...

Page 14: ... showgfp PFI 0 EXI 0 PSCRD Enable HSCRD Enable GFP SYNC Alarm AC Mains Input 220V AC Optional DC Mains Input 48V Power Consumption 4 Watts 0 0 Ambient temperature 0 C 50 C 0 Relative humidity 90 at 35 C 238mm x 125mm x 44mm 980gm General Power Supply Service Conditions Dimensions Weight 16 Black Iris For Telecom Technology 2008 ...

Reviews: