3. Using two wrenches, hold the injector with one and back off the steel feed line nut with the other wrench.
Repeat the above mentioned flushing cycle to bleed the air from the injector. Wipe all spilled fuel from
the engine and components. Note: Do not close the fuel valve with the engine running. This may only be
done for the intention of shutting the engine off should the fuel shut-off system fail.
Connect the Battery
The Generator ships with the negative battery cable disconnected. Before the generator can be started the
covering on the battery cable must be removed and the cable must be secured to the negative ground
terminal on the battery. Recheck battery’s positive terminal connection for tightness.
How to Shut Engine Off
A diesel engine is not operated like a gasoline engine. When operating a diesel engine, one should be
aware of various options of how to shut the engine off.
1. Turn the ignition key to the off position.
2. Push down on the fuel shut off lever to release the Control Handle (13).
3. Turn the fuel valve to its “OFF” position.
Start Procedure
Before starting the engine:
a. Follow the Set Up Instructions to prepare the equipment.
b. Inspect the equipment and
engine.
c. Fill the engine with the proper amount and type of fuel and oil.
e. Read the Equipment Operation section that follows.
To start the engine:
1. Unplug all loads from the Generator before starting to prevent permanent damage to any appliances or
tools.
2. Depress the Decompression Handle (16) all the way (Cold starting only).
3. Open the front panel and turn the fuel shut-off valve to its “OPEN” position.
4. Rotate the Control Handle (13) to the right until release button on the Right hand side of the Handle
Bracket (12) pops up and locks in place.
7
5. Insert the engine key into the ignition and turn it to “START” position for up to 10 seconds. Note: To
prolong starter life, use short starting cycles (10 seconds maximum). If the engine does not start, wait
one minute before attempting to start again.