Installation 25
Setting Jumpers
Terminal Server RJ45
To change the settings, do the following:
1.
Unplug the Terminal Server from the electrical outlet and disconnect everything from the
box.
2.
Open the case by unscrewing the two side screws, one on each side, and lifting off the top of
the case. You should see the following:
3.
To change the power pin out, locate J4. For the fixed 5V DC output, jumper pins 1 and 2. For
the output to equal the external adapter input, jumper pins 2 and 3.
4.
To turn line termination
on
, locate and jumper both J1 and J9.
5.
Close the Terminal Server case by replacing the case lid and the two screws. You can now
power it on with the new settings.
Terminal Server DB9
To change the settings, do the following:
1.
Unplug the Terminal Server from the electrical outlet and disconnect everything from the
box.
2.
Open the case by unscrewing the two side screws, one on each side, and lifting off the top of
the case. You should see the following:
3.
To turn line termination
on
, locate and jumper both J11 and J9.
4.
Close the Terminal Server case by replacing the case lid and the two screws. You can now
power it on with the new settings.
Power
Dip
Switch
Reset
RJ45
RJ45
Pin1
Screw
Screw
J1
J9
J4
Power
Dip
Switch
Reset
RJ45
DB9 Serial
Screw
Screw
J1
1
J9
Summary of Contents for Terminal Server
Page 20: ...Typical Applications Summary 20 Terminal Server User Guide ...
Page 82: ...Tools 82 Terminal Server User Guide ...
Page 118: ...Statistic Commands 118 Terminal Server User Guide ...
Page 124: ...COMredirect 124 Terminal Server User Guide ...
Page 126: ...126 Terminal Server User Guide ...
Page 130: ...W 130 Terminal Server User Guide ...