5
CHAPTER 1: Specifications
1.1 Specs for Pow-R-Switch (SWI030, SWI031) Units:
Compliance —
FCC Class A, IC Class/classe A
Interfaces —
All models: Serial EIA RS-485;
Pow-R-Switch 1M (SWI030) models only: Serial EIA
RS-232 (DTE), IBM AT implementation
Protocol —
Asynchronous
Code Set —
ASCII
Data Format —
8 data bits, no parity, 1 stop bit (fixed)
Flow Control —
None
Data Rate —
2400 or 9600 bps, user-selectable
Maximum
Distance —
RS-232 (Control) side: 50 ft. (15.2 m);
RS-485 (Link) side: 2000 ft. (609.6 m) to farthest
Pow-R-Switch 1S (SWI031) module
User Controls —
Keyboard commands;
(2) Rear mounted: (1) Rotary dial for addressing and
(1) 4-position DIP switch for data rate, toggle delay,
and default outlet state
Indicators —
(3) Front-mounted LEDs: AC ON, LINK, and RDY
(ready)