7
CHAPTER 3: Installation
3.1 Setting the Internal DIP Switches
Remove the cover of the Switch’s enclosure to
expose the PC board.
Figure 1 shows the location of the Code Operated
Matrix Switch’s internal DIP switches. There are two
types:
1. Individual Port Switches (see
Section 3.1.1
)
2. System Switches (these apply to all ports; see
Section 3.1.2
)
NOTE: DIP Switches may have different
designators to indicate the “ON” and “OFF”
settings. In this manual, “ON” is equivalent
to “Closed” and “OFF” is equivalent to
“Open.”
3.1.1
I
NDIVIDUAL
P
ORT
C
ONFIGURATIONS
A number of options can be configured for each
port individually. You can select:
• Baud rate: 110, 300, 600, 1200, 2400, 4800, 9600,
or 19,200 bps
• Parity: Even, odd, or none
• Data bits per word: 7 or 8
• Flow Control: Hardware (DTR/CTS) or software
(X-ON/X-OFF)
• Break detection: Break to disconnect or ignore
breaks
3. Installation
(BACK)
PORT 4
PORT 3
PORT 2
PORT 1
PORT 0
DTE
DCE
J7
U23
U20
J1
W1
VR1
RESET BUTTON
S1
R1
SW
G
SW
F
SW
E
SW
D
SW
C
SW
B
SW
A
SYSTEM SWITCHES
(SWF & SWG)
INDIVIDUAL PORT SWITCHES
STATUS INDICATORS
CH0CH1CH2CH3CH4CH5CH6CH7CH8
PWR
(FRONT)
DTE
DCE
DTE
DCE
DTE
DCE
DTE
DCE
OFF
OFF
OFF
OFF
OFF
OFF
OFF
PORT 4
PORT 3
PORT 2
PORT 1
PORT 0
Fig. 1. Internal Switch Locations for the Standard Code Operated Matrix Switch