background image

13

CHAPTER 4: Operation

4.3 The Terminal Display and Scroll Buffer

With the Serial Upgrade Kit, the ServSwitch Affinity implements industry-standard
VT100 terminal emulation. You can also use it in standard TTY mode and it will
automatically scroll incoming data. Figure 4-2 shows a typical screen from a UNIX
computer. The serial data from the computer is shown in the standard 24 x 80
area. Below the data are two status lines. The first line shows the current user-
station name (“NOC station 12”), user name (“Martin”), connect mode (“Share
mode”), and computer name (“Unix NCC”) that are currently in use. These fields
all reflect the Affinity’s current state.

The Affinity also implements an eight-page scroll buffer. View up to eight pages

of previous data using the page-up [PgUp] and page-down [PgDn] keys as shown
in the second status line. Use the [F12] key to clear the screen. The number of the
page to which you’ve scrolled is shown at the right of the second status line. The
two colors on the screen correspond to the background and text colors that you
can set in the Affinity’s “Configure System” page (see the “Configuring the System”
section in your Affinity manual).

Figure 4-2. Screen shot of an Affinity terminal session with a 

UNIX computer.

-r-sr-xr-x   2 uucp    uucp      31258 Aug 14 2001  uusnap

-r-sr-xr-x   2 uucp    uucp      31258 Aug 14 2001  uustat

-r-xr-xr-x   1 uucp    uucp       1759 Feb 09 2001  uuto

-r-sr-xr-x   1 uucp    uucp      50678 Aug 14 2001  uux

-r-xr-xr-x   1 bin     bin        8868 Apr 09 2001  vacation

-r-xr-xr-x   5 bin     bin      224806 Jun 07 2002  vedit

-r-xr-xr-x   5 bin     bin      224806 Jun 07 2002  vi

-r-xr-xr-x   5 bin     bin      224806 Jun 07 2002  view

-r-xr-sr-x   2 root    system    14830 Jun 07 2002  w

-r-xr-xr-x  15 bin     bin        1042 Jun 07 2002  wait

-r-xr-xr-x   1 bin     bin        5050 Jun 07 2002  wc

-r-xr-xr-x   1 bin     bin        3372 Jun 07 2002  what

-r-xr-xr-x   3 bin     bin       96640 Jun 07 2002  whatis

-r-xr-xr-x   1 bin     bin        6840 Jun 07 2002  whereis

-r-xr-xr-x   1 bin     bin         963 Jun 07 2002  which

-r-xr-xr-x   1 bin     bin       10912 Jun 07 2002  who

-r-xr-xr-x   1 bin     bin        1598 Jun 07 2002  whoami

-r-xr-xr-x   1 bin     bin       18624 Jun 07 2002  write

-r-xr-xr-x   1 bin     bin       10694 Jun 07 2002  xargs

-r-xr-xr-x   1 bin     bin       12732 Apr 09 2001  xget

-r-xr-xr-x   1 bin     bin       12272 Apr 09 2001  xsend

-r-xr-xr-x   1 bin     bin        1334 Jun 07 2002  yes

-r-xr-xr-x   3 bin     bin       14552 Jun 07 2002  zcat

# _

Affinity terminal •NOC station 12  •Martin  •Share Mode  •Unix NCC

Page    = Scroll  •F12 = Clear screen                    •Page 0

Summary of Contents for ServSwitch KV130-UPG

Page 1: ...24 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox...

Page 2: ...ne of robust solutions for all these applications Do you have just two PCs and need an economical alternative to keeping two monitors keyboards and mice on your desk Or do you need to share dozens of...

Page 3: ...t off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and rec...

Page 4: ...ato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante 8 Servicio El usuario no debe intentar dar servicio al equipo el ctrico m s all a lo descrito en las in...

Page 5: ...u orificios de ventilaci n 18 Servicio por personal calificado deber ser provisto cuando A El cable de poder o el contacto ha sido da ado u B Objectos han ca do o l quido ha sido derramado dentro del...

Page 6: ...e 1 Specifications 6 2 Introduction 7 3 Installation 8 4 Operation 11 4 1 Overview and Cabling 11 4 2 Configuration 12 4 3 The Terminal Display and Scroll Buffer 13 5 Troubleshooting 15 5 1 Calling Bl...

Page 7: ...TIA RS 232 proprietarily pinned on DB25 Protocol RS 232 Asynchronous Data Format RS 232 8 data bits no parity 1 stop bit fixed Data Rate RS 232 50 110 300 600 1200 2400 4800 or 9600 bps user selectab...

Page 8: ...in your ServSwitch Affinity system NOTE If you have R3 version Matrix ServSwitches attached to your ServSwitch Affinity system you won t be able to attach serial devices to the Matrix ServSwitches but...

Page 9: ...he OSD daughtercard and you ll need to call Black Box Technical Support Without messing around with the Affinity s hardware at all you can check the revision level in one of two ways a Cycle power to...

Page 10: ...where a b c and d are revision numbers If the large right hand chip is labeled with a revision earlier than O4 2 you won t be able to install the Upgrade Kit in the field Please skip the remainder of...

Page 11: ...mands to switch between the ports if necessary If any switching commands fail make sure that the new chips are seated firmly on the daughterboard and that the Port Card is seated firmly in the slot If...

Page 12: ...erial Upgrade Kit modifies the OSD firmware to implement VT100 101 102 202 terminal emulation scrolling a hardware cursor cursor controls and other necessary elements to convert and format serial data...

Page 13: ...o move the highlight bar to the data rate you want then press Enter In the example shown in Figure 4 1 the Computer 1 port has already been set to be a 9600 bps serial port and the Computer 2 port is...

Page 14: ...figure System page see the Configuring the System section in your Affinity manual Figure 4 2 Screen shot of an Affinity terminal session with a UNIX computer r sr xr x 2 uucp uucp 31258 Aug 14 2001 uu...

Page 15: ...get a blank screen with the cursor in the upper left hand corner As you interact with the computer the screen fills up with data This data is stored in the Affinity in a separate buffer for each compu...

Page 16: ...and duration of the problem when the problem occurs the components involved in the problem any particular application that when used appears to create the problem or make it worse and the results of...

Page 17: ...1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 Copyright 2002 Black Box Corporation All rights reserved...

Reviews: