MULTISERVER 500
38
Device Number:
0 through 8
Example:
>CMD RA=9600
will set the Command
Port rate to 9600.
Be sure to separate each command in the string
by a space. To save the newly set parameters in
EEPROM, type
>SA <cr>
.
COMpositelink
Clock
External, Internal
Rate (bps)
7200, 9600, 14400,
19200, 38400, 56000,
64000, 72000
Example:
>COM CL=EX RA=56000 <cr>
, will set
the composite port clock to external, and the rate
to 56,000 bps. Rate selection applies to internal
clock only.
Be sure to separate each command in the string
by a space. To save the newly set parameters in
EEPROM, type
>SA <cr>
DAtaport
Use this command to select the data port type and
parameters that are common to both the
synchronous and asynchronous data channels.
Parameters that are unique to the synchronous and
asynchronous channels are set by separate
commands for each type.
Type
Asynchronous,
Synchronous
CTS
ON, OFF, Local
(Follows local RTS)
CTSDelay
None, 25, 75, 100, 125,
150 in msec
DCD
ON, OFF, Remote
(follows remote RTS)
DSR
ON, OFF, Remote
(follows remote DTR)
RI
ON, OFF, Link (follows
link status)
Example:
>DA TY=SY RI=OFF
will set the data
port type to synchronous, and the ring indicator to
off.
Be sure to separate each command in the string
by a space. To save the newly set parameters in
EEPROM, type
>SA <cr>
.
DIAgnostics
SElftest
Initiates a self-test
EEprom
Initiates a nonvolatile
RAM check
LOCComp
Initiates a local
composite loopback
REMComp
Initiates a remote
composite loopback
LOCDat
Initiates a local data
channel loopback
REMDat
Initiates a remote data
channel loopback
TErminate
Terminates test in
progress, such as self-
test or loopback
Example: To initiate a remote-data-channel
loopback test, type:
>DI REMD <cr>
.
SHow
DATE
Displays today’s date
Example:
>SH DATE 03/11/94
Status Displays
Multiserver
500’s current general
status, including self-
test, loopback, and
hardware type and
revision.
Example:
>SH S
System Status: 20 MHz DSP, 64K RAM,
no download capability
Main module 001 Voice & Data
Revision Level: B
Voice/Fax Interface Module: 002
Revision Level: 03
Interface Type: Enhanced FXS, Loop
start.