Fiber Optic Cable Attachment: 

Connect the fiber cables between the Flex Point T1/E1 converters.  The transmit (Tx) 
must attach to the receive (Rx) side and the receive (Rx) side must attach to the transmit 
(Tx) side. 

Note:

  Use fiber cables that are compliant with the specifications that are outlined in fiber 

cable specifications. 
 

Copper Cable Attachment: 

RJ-45 / RJ-48   T1 / E1 connector 

Connect to the RJ-45/48 connector on the Flex Point T1/E1 converter via a category 3 or 
better cable (Category 5 is recommended) and attach the other end to the network 
equipment.  (the twisted pair connection requires two active pairs in a T1/E1 
environment.  The active pairs are pins 1&2 and pins 4&5.  Only dedicated wire pairs 
should be used for the active pins.)  Set the UTP DCE/DTE switch for the RJ-45/48 port 
to the appropriate setting. 

Note:

  Use copper cables that are compliant with the specifications that are outlined in 

copper cable specifications. 
 

Coax E1 Connector 

Attach the BNC to the Flex Point T1/E1 converter and attach the other end of the BNC to 
the network equipment.   

Note:

  Use copper cables that are compliant with the specifications that are outlined in 

copper cable specifications. 
 
 
 

Switch Settings: 

UTP  DCE/DTE setting 

The UTP DCE/DTE switch is used to eliminate the need for crossover and custom cables 
to connect devices together when using the RJ-45/48 port.  Set this switch to DCE to use 
a straight-through cable and to DTE when a crossover-cable would be required. 
 

DCE

DTE

    Twisted  - 1 -  RTIP

    TTIP

    Pair        - 2 -  RRING

    TRING

    Twisted  - 4 -  TTIP                RTIP
    Pair        - 5 -  TRING

    RRING

    Twisted  - 1 -  RTIP

       TTIP

    Pair        - 2 -  RRING

       TRING

    Twisted  - 4 -  TTIP

       RTIP

    Pair        - 5 -  TRING

       RRING

 

 
 

Summary of Contents for MT660A-MM

Page 1: ...TOMER Order toll free in the U S Call 877 877 BBOX SUPPORT outside U S call 724 746 5500 INFORMATION FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing a...

Page 2: ...with a Listed Direct Plug In Power Unit marked Class 2 and rated at 9VDC 1 Amp 2 This product should always be used only with the supplied power unit 3 Models shipped with international power supplie...

Page 3: ...ed for the active pins Set the UTP DCE DTE switch for the RJ 45 48 port to the appropriate setting Note Use copper cables that are compliant with the specifications that are outlined in copper cable s...

Page 4: ...1 DS 1 RJ 45 48 0 dB D D D D T1 DS 1 RJ 45 48 7 5 dB D U D U T1 DS 1 RJ 45 48 15 0 dB D U U D T1 DS 1 RJ 45 48 22 5 dB D U U U E1 75 ohm Coax BNC Standard U D D D E1 120 ohm RJ 45 48 Standard U D D U...

Page 5: ...eceived on the coax or twisted pair will be disabled and data being received on the fiber is passed through to the coax or twisted pair side By returning the switch to the normal position the unit wil...

Page 6: ...of operation and return a signal to the sending unit An LED on the local and remote Flex Point T1 E1 converters will show a configuration that the fiber segment is communicating properly between devi...

Page 7: ...nk All Ones received Test Green Off Normal Operation On L LB or All 1 s Test Mode Blink R L LB Received Master Fast Blink R L LB Received Slave Fiber Cable Specifications Multimode Cable 50 125 62 5 1...

Page 8: ...ance 6 000 ft Twisted Pair cable for E1 Gauge 22 to 24 AWG Impedance 120 ohm 10 Impedance characteristic 2 6 dB 100m 1 0 MHz Maximum Distance 8 000 ft Coax cable for E1 Gauge 22 to 24 AWG Impedance 75...

Reviews: