Black Box MDU9705A-V35 Manual Download Page 14

Using the V.52 (BER) Test Pattern Generator

To use the V.52 BER tests in conjunction with the Remote Digital

Loopback tests (or with Local Line Loopback tests), follow these
instructions:

1.  

Locate the “511/511E” toggle switch on the front panel of the 
Compact mDSL Modem and move it UP.  This activates the 
V.52 BER test mode and transmits a “511” test pattern into the
loop.  If any errors are present, the local modem’s red “ER” 
LED will blink sporadically.  

2.   If the above test indicates no errors are present, move the 

V.52 toggle switch DOWN, activating the “511/E” test with 
errors present.  If the test is working properly, the local 
modem's red “ER” LED will glow.  A successful “511/E” test 
will confirm that the link is in place, and that the Compact 
mDSL Modem built-in “511” generator and detector are work
ing properly.

NOTE:

The above V.52 BER tests can be used independently

of  the Remote Digital Loopback tests.  This requires two opera-
tors:  (1) to initiate and monitor the tests at the local Compact
mDSL Modem, and (2) to do the same at the remote Compact
mDSL Modem.  In this case, the test pattern sent by each
Compact mDSL Modem will not be looped back, but will be
transmitted down the line to the other Compact mDSL Modem.
While one operator initiates test, the other monitors for errors.

25

Compact mDSL Modem  

26

Compact mDSL Modem  

APPENDIX A

BLACK BOX COMPACT MDU9705A-V35 

AND MDU9705A-X21 SPECIFICATIONS

Clocking Modes:  

Internal, External, or Receive Recovered

DTE Rate:

All 64k steps from 64 to 2304 kbps

DTE Interface:

V.35 (Compact mDSL Modem), DCE 
Orientation;
X.21 (Compact mDSL Modem), DCE or 
DTE Orientation depending upon orientation
of pc-board mounted daughter board

DTE Connector:

M/34 Female (Compact mDSL Modem)
D-Sub-15 Female (Compact mDSL 
Modem)

Diagnostics:

V52 compliant (511/511E) pattern generator
and detector with error injection mode con-
trolled by front panel switch, Local and 
Remote Loopback control by either a front 
panel switch or from the DTE interface

LED Status:

The following LEDs are displayed on the 
front panel:
DSL Link (Green Active) - DSL Link Active
TD, RD (Yellow/Green) - Idle Yellow
NS (Red Active) - No signal DSL Link
ER (Flashing Red) - CRC error during nor-
mal operation, bit error during pattern gen-
eration test
TM (Active Yellow) - Test Mode Enabled

Configuration:

Externally accessible dip switches or SNMP
managed through mDSL Rack Card

Power:

+5 VDC external desk top power supply, 90-
260VAC, 50-60 Hz (Universal Input), 10W 
or -48 VDC

Compliance:

FCC Part 15, CE, CTR1

Transmission Line:

Single Twisted Pair

Line Coding:

CAP (Carrierless Amplitude and Phase 
Modulation

Line Rates (DSL line): 

144, 272, 400, 528, 784, 1040, 1552, 2064, 
2320 kpbs

Line Interface:

Transformer coupled, 1500 VAC isolation

mDSL Physical 
Connection:  

RJ-45, 2 wire, polarity insensitive pins 4 
and 5

Environment:  

Operating temperature 0-50°C; humidity 5-
95% non-condensing; altitude, 0-15, 000 
feet (0-4600 m)

Summary of Contents for MDU9705A-V35

Page 1: ...6000 0118 965 5100 0118 931 5001 464 Basingstoke Road Reading Berkshire RG2 0QN www blackbox co uk Compact mDSL Modem 464 Basingstoke Road Reading Berkshire RG2 0QN Copyright 2000 Black Box Catalogue...

Page 2: ...properly that is in strict accor dance with the manufacturer s instructions may cause interference to radio and television reception The Compact mDSL Modem has been tested and found to comply with the...

Page 3: ...ilities using NetLink Plug and Play and inband externally accessible configuration switches All ver sions of the Compact mDSL Modem are compatible with Black Box s mDSL standalone and mDSL Access rack...

Page 4: ...Unit S2 6 S2 7 Clock Mode Description CO On On Internal Transmit clock generated inter nally CO Off On External DTE Transmit clock derived from terminal inter face CP On Off Receive Recover Transmit...

Page 5: ...Transmit Data Sample Point On Normal Operation 768 kbps 7 Compact mDSL Modem 8 Compact mDSL Modem On Off On Off Off On 1536 On On Off Off Off On 1600 Off On Off Off Off On 1664 On Off Off Off Off On...

Page 6: ...of the CO unit should be changed This feature gives ISPs LECs and PTTs the ability to provision bandwidth on an as needed basis to cus tomers mDSL Rack Card CO 1088 CP DIP Switches all in OFF position...

Page 7: ...V35 to V 35 Serial DCE Straight Through M 34 Cable DSL Span MDU9705A V35 DCE Remote Compact mDSL Modem V 35 Router DTE DSL Span Remote Compact mDSL Modem MDU9705A V35 DCE V 35 Multiplexer DCE Figure 4...

Page 8: ...arrel jack on the rear panel Many international power cords are available for the universal power supply Please refer to Appendix B for country specific power cords The Compact mDSL Modem powers up as...

Page 9: ...Panel Compact mDSL Modem V 35 15 Compact mDSL Modem 16 Compact mDSL Modem only at power up blinks once every 200 ms if the DTE Rate is set to an unsupported settings TM glows yellow to indicate that...

Page 10: ...is looped back to the line but it is also allowed to pass through to the framer and to the remote DTE Pattern Gen Det Loop Control Loop Control Pattern Gen Det Processor Processor Framer Framer Line 1...

Page 11: ...data presented at the far end DTE will be transmitted to the local DTE and then looped back within the local DTE Loop Control block with the Processor After the Local Loop is deselected the units will...

Page 12: ...mpact mDSL Modem 22 Compact mDSL Modem Remote Digital The Remote Loop uses the EOC channel an Loop out of band signaling channel to establish the remote link Upon the RDL switch being thrown or DTE in...

Page 13: ...he units enter DataMode it is possible to 511 511E Pattern turn on the 511 511E pattern generators on Generators both ends of the link Once a 511 511E pattern is selected on one end of the link the pa...

Page 14: ...BLACK BOX COMPACT MDU9705A V35 AND MDU9705A X21 SPECIFICATIONS Clocking Modes Internal External or Receive Recovered DTE Rate All 64k steps from 64 to 2304 kbps DTE Interface V 35 Compact mDSL Modem...

Page 15: ...Source V RC Receiver Clock DCE Source W XTC External Transmit Clock DTE Source X RC Receiver Clock DCE Source Y TC Transmitter Clock A DCE Source AA TC Transmit Clock B DCE Source 27 Compact mDSL Mod...

Page 16: ...048 12200 2 3 3 8 17200 3 3 5 3 2320 2112 2304 11500 2 2 3 5 15800 3 0 4 9 Line Rate DTE Rates kbps feet miles km feet miles km 144 64 128 16992 3 2 5 2 25000 4 7 7 7 272 192 256 15088 2 9 4 6 22000 4...

Reviews: