Black Box MDU9705A-V35 Manual Download Page 13

Remote Digital 

The Remote Digital Loop with 511/511E is

Loop with

shown above. After RDL is established the

511/511E

Remote units' Restart Timer is set to one

minute. This has been done because when the
511/511E generator is started on the local unit,
the Remote framer begins seeing unframed
packets. The Remote unit can not distinguish
the 511/511E pattern from the line being discon-
nected so the Restart Timer has been length-
ened to allow the pattern generator to function.
Once the 511/511E test is started, the Local unit
changes its' Restart Timer to one minute. The
pattern originates within the Processor  and is
sent to the Remote unit. It is then looped back
to the Local unit where it is evaluated for errors.
After 45 seconds, the Pattern Generator will
timeout and stops sending the pattern. The ER
led will begin blinking until the user turns off the
511/511E switch.

Figure 17. Block Remote Loop with 511/511E

Pattern

Gen/Det

Loop

Contr

ol

Loop

Contro

l

Pattern

Gen/Det

Processor

Processor

Framer

Framer

Line

23

Compact mDSL Modem  

24

Compact mDSL Modem  

Data Mode with

When the units enter DataMode it is possible to

511/511E Pattern

turn on the 511/511E pattern generators on

Generators

both ends of the link. Once a 511/511E pattern
is selected on one end of the link, the pattern
generator will begin transmitting unframed
511/511E through the line to the Remote end. A
possible problem with this test can occur due to
the Restart procedure. Once the Local 511/511E
is turned on, the Remote unit begins receiving
an unframed 511 pattern. If the Remote unit
does not turn on the 511/511E-pattern generator
within 4 seconds, the Remote unit will Restart
and enter the StartUp mode. Note that once the
511/511E-pattern generator is started the
Restart timer is changed to one minute (only on
the unit which has the pattern enabled). If both
units enable the 511/511E pattern within 4 sec-
onds of each other, both units will be transmit-
ting and receiving the 511/511E pattern. Both
framers are now receiving unframed data and
will restart after one minute. The 511/511E pat-
tern generators will TimeOut after 45 seconds
re-enabling the normal data path. The ER led
will begin flashing until the user terminates the
test.

Figure 18. Block Diagram DataMode with 511/511E

Pattern

Gen/Det

Loop

Contr

ol

Loop

Contro

l

Pattern

Gen/Det

Processor

Processor

Framer

Framer

Line

Summary of Contents for MDU9705A-V35

Page 1: ...6000 0118 965 5100 0118 931 5001 464 Basingstoke Road Reading Berkshire RG2 0QN www blackbox co uk Compact mDSL Modem 464 Basingstoke Road Reading Berkshire RG2 0QN Copyright 2000 Black Box Catalogue...

Page 2: ...properly that is in strict accor dance with the manufacturer s instructions may cause interference to radio and television reception The Compact mDSL Modem has been tested and found to comply with the...

Page 3: ...ilities using NetLink Plug and Play and inband externally accessible configuration switches All ver sions of the Compact mDSL Modem are compatible with Black Box s mDSL standalone and mDSL Access rack...

Page 4: ...Unit S2 6 S2 7 Clock Mode Description CO On On Internal Transmit clock generated inter nally CO Off On External DTE Transmit clock derived from terminal inter face CP On Off Receive Recover Transmit...

Page 5: ...Transmit Data Sample Point On Normal Operation 768 kbps 7 Compact mDSL Modem 8 Compact mDSL Modem On Off On Off Off On 1536 On On Off Off Off On 1600 Off On Off Off Off On 1664 On Off Off Off Off On...

Page 6: ...of the CO unit should be changed This feature gives ISPs LECs and PTTs the ability to provision bandwidth on an as needed basis to cus tomers mDSL Rack Card CO 1088 CP DIP Switches all in OFF position...

Page 7: ...V35 to V 35 Serial DCE Straight Through M 34 Cable DSL Span MDU9705A V35 DCE Remote Compact mDSL Modem V 35 Router DTE DSL Span Remote Compact mDSL Modem MDU9705A V35 DCE V 35 Multiplexer DCE Figure 4...

Page 8: ...arrel jack on the rear panel Many international power cords are available for the universal power supply Please refer to Appendix B for country specific power cords The Compact mDSL Modem powers up as...

Page 9: ...Panel Compact mDSL Modem V 35 15 Compact mDSL Modem 16 Compact mDSL Modem only at power up blinks once every 200 ms if the DTE Rate is set to an unsupported settings TM glows yellow to indicate that...

Page 10: ...is looped back to the line but it is also allowed to pass through to the framer and to the remote DTE Pattern Gen Det Loop Control Loop Control Pattern Gen Det Processor Processor Framer Framer Line 1...

Page 11: ...data presented at the far end DTE will be transmitted to the local DTE and then looped back within the local DTE Loop Control block with the Processor After the Local Loop is deselected the units will...

Page 12: ...mpact mDSL Modem 22 Compact mDSL Modem Remote Digital The Remote Loop uses the EOC channel an Loop out of band signaling channel to establish the remote link Upon the RDL switch being thrown or DTE in...

Page 13: ...he units enter DataMode it is possible to 511 511E Pattern turn on the 511 511E pattern generators on Generators both ends of the link Once a 511 511E pattern is selected on one end of the link the pa...

Page 14: ...BLACK BOX COMPACT MDU9705A V35 AND MDU9705A X21 SPECIFICATIONS Clocking Modes Internal External or Receive Recovered DTE Rate All 64k steps from 64 to 2304 kbps DTE Interface V 35 Compact mDSL Modem...

Page 15: ...Source V RC Receiver Clock DCE Source W XTC External Transmit Clock DTE Source X RC Receiver Clock DCE Source Y TC Transmitter Clock A DCE Source AA TC Transmit Clock B DCE Source 27 Compact mDSL Mod...

Page 16: ...048 12200 2 3 3 8 17200 3 3 5 3 2320 2112 2304 11500 2 2 3 5 15800 3 0 4 9 Line Rate DTE Rates kbps feet miles km feet miles km 144 64 128 16992 3 2 5 2 25000 4 7 7 7 272 192 256 15088 2 9 4 6 22000 4...

Reviews: