Abbreviated Command List
Page 255
&F1
Select non-error correction factory
defaults
&F2
Select synchronous mode factory
defaults
&G0
n
Do not generate guard tones
&G1
Generate guard tones of 550Hz
&G2
Generate guard tones of 1800Hz
&H0
n
Clock always present in
synchronous mode
&H1
Clock only appears after
connection
&K0
Flow control disabled
&K3
n
RTS/CTS (hardware) flow control
&K4
XON/XOFF (software) flow control
&K5
Transparent XON/XOFF flow
control
&K9
Failsafe flow control
&L0
n
PSTN mode
&L1
Leased-line mode
&L2
Auto leased line Originate mode
&L3
Auto leased line Answer mode
&M 0
n
Asynchronous mode
&M 1
Synchronous mode with
asynchronous dialling
&M 2
Synchronous mode with dialling
invoked by the DTR signal
&M 4
Asynchronous mode with dialling
invoked by the DTR signal
&N0
Disable abort connection
&N1
n
Enable abort connection
&R0
n
CTS follows RTS when the modem
is on line.
&R1
CTS is always asserted.
&S0
n
DSR signal will always be asserted
&S1
DSR signal asserted at the start of
handshake
&S2
DSR signal asserted at end of
handshake (before CONNECT
message)
&Vn
View Active Configuration Profile
&V0
View stored configuration profile 0
&V1
View stored configuration profile 1
&V2
View stored configuration profile 2
&V3
View stored configuration profile 3
&V8
View differences between active
configuration and default settings of
the S Registers
& W n
Write Configuration Parameters
& W 0
Save current configuration into
profile 0
& W 1
Save current configuration into
profile 1
& W 2
Save current configuration into
profile 2
& W 3
Save current configuration into
profile 3
&X0
n
Synchronous clocks generated by
Modem.
&X1
Clocks generated by computer -
external clocking.
&X2
Clocks generated by remote system
- slave clocking.
&Y0
Select stored profile 0 on power up
&Y1
Select stored profile 1 on power up
&Y2
Select stored profile 2 on power up
&Y3
Select stored profile 3 on power up
& Z
Stored Phone Number
#A0
Prevent remote access
#A1
Allow remote access
#A2
n
Allow remote access with security
password
#B0
n
B0 = V.23 B2 = V.22
#B1
B0 = V.22 B2 = V.23
#C0
V.25 calling tones disabled
#C1
n
V.25 calling tones enabled
#CID0
n
Caller ID
disabled
#CID1
Caller ID enabled
#CID2
Caller ID enabled with
response to host in hex format
#CID3
Caller ID enabled with
extended response
#D0
n
Disable direct calling procedures
#D1
Enable direct calling procedures
#E0
n
DES encryption disabled
#E1
DES encryption enabled
#E2
SuperSecure enabled (some models
only)
#E3
DES MultiKey
#E4
DES AutoIV
# H
Display Help
# I0
n
V.22bis leased line normal
# I1
Use non-standard PSTN V.22bis
over leased line
#J0
Assume V.42 capable
Summary of Contents for MD1276A
Page 1: ...MD1276A Global 56K V90 Modem User s Guide 0049 2200 001 Rev A FEBRUARY 2004 0049 2200 500...
Page 128: ...Page 128 Range 0 2...
Page 223: ...S Registers Page 223 See Also ATS105Voice Dead man Timer Range 0 255...
Page 250: ...Page 250 Standard RS 232 Examples...
Page 260: ...Page 260...
Page 288: ...Page 288...
Page 289: ......