6
LOBE ACCESS UNIT
Operating Voltage —
4.5 ±0.7 volts
Operating Current —
1.0 mA @ 5 VDC
Resistance TX to RX —
4.8 ±0.2 k
Ω
Insertion Time —
5 seconds
Removal Time —
50 to 200 msec
Insertion Loss (Maximum) —
0.5–4 MHz 4–16 MHz
16–32 MHz
SUB TX to SUB RX
0.65 dB
1.3 dB
2.6 dB
MAIN RX to SUB RX
0.85 dB
1.8 dB
3.7 dB
SUB TX to MAIN TX
0.85 dB
1.8 dB
3.7 dB
Crosstalk (Maximum) —
10 KHz
0.5–4 MHz 4–16 MHz
SUB TX to SUB RX
55 dB
43 dB
37 dB
SUB WRAP to MAIN
50 dB
40 dB
35 dB
Return Loss (Minimum) —
1–6 MHz
6–12 MHz
12–24 MHz
20 dB
14 dB
11 dB
1. Specifications