LOBE ACCESS UNIT
3.1 Set-Up Procedures
Before connecting the unit to the network, use the
initialization tool (LT037, sold separately) as follows:
1. Connect the initialization tool to the port labeled
SUB-1 for about 10 seconds.
2. The two LEDs on the initialization tool should
light up and then fade. Up to two clicks should
be heard.
3. After both LEDs on the initialization tool have
faded completely (about 6 seconds), remove the
initialization tool. Two clicks should be heard.
4. Repeat the procedure for ports SUB-2 through
SUB-4. Note that for port SUB-4, only a single
LED will light on the tool, and only one click
will be heard.
3.2 The Standalone Option
The Lobe Access Unit can work as a standalone unit
if you set a switch inside the unit. Open the unit by
pressing the marked places on both sides. The switch
is located to the right of the MAIN connector. If you