background image

©

Copyright 2006. Black Box Corporation. All rights reserved.

Summary of Contents for LPM600A

Page 1: ...Copyright 2006 Black Box Corporation All rights reserved...

Page 2: ...e U S call technical support 24 hours a day 7 days a week Call or fax Mailing address 1000 Park Drive Lawrence PA15055 1018 Web site E mail toll free 877 877 BBOX 724 746 5500 FREE 724 746 5500 724 74...

Page 3: ......

Page 4: ...ved by the party responsible for compliance could void the user s authority to operate the equipment This digital apparatus does not exceed the Class A limits for radio noise emission from digital app...

Page 5: ...10 El equipo el ctrico deber ser situado fuera del alcance de fuentes de calor como radiadores registros de calor estufasu otros aparatos incluyendo amplificadores que producen calor 11 El aparato el...

Page 6: ...ed trademark of AT T BLACK BOX and the Double Diamond logo are registered trademarks of BB Technologies Inc Any other trademarks mentioned in this manual are acknowledged to be the property of the tra...

Page 7: ...LNK ACT FDX COL 4W 7W 15 4W Data Transfer Rate 148 800 pps at 100 Mbps 14 880 pps at 10 Mbps Flow Control IEEE802 3x compliant for full duplex Backpressure flow control for half duplex Power Requireme...

Page 8: ...ection and power out auto detection to PD 2 2 Model Description Part Number Single Multi Mode Connector Type Wavelength Transmission Distance LPM600A Multi Mode SC Type 1310 nm 2 km LPM601A Multi Mode...

Page 9: ...active Blinks when collision is present TP LNK ACT Green Lit when TP connection is good Blinks when TP data is present TP 100 Green Lit when TP speed is 100Mbps Off when TP speed is 10Mbps PWR Green...

Page 10: ...The media converter s rear panel is shown in Figure 2 2 Figure 2 2 Rear panel CHAPTER 2 Overview 7...

Page 11: ...o an AC power source 2 Install the TP media cable to the IEEE 802 3af PD device See Figure 3 1 NOTE This converter can work as a pure converter that connects to the non PoE converter 3 Install the med...

Page 12: ...1 2 3 6 3 2 Connecting to TP Fiber Device Converter TP Port 10 100 TP AUTO FORCE selectable Bit 1 2 3 of S1 a AUTO 10 100 NWay Auto negotiation b FORCE 100 or 10 FDX or HDX Converter Fiber Port 100FX...

Page 13: ...PoE ON OFF Enable default or disable NOTE 1 S1 2 and S1 3 will take effect only when S1 1 is set at TP FORCE 2 S1 5 must be set to 100FDX for Single Fiber Model 3 S1 6 must be set to PoE ON while powe...

Page 14: ...based Media Converter breaks up TP and Fiber segments collision domain to extend the cabling distance TP Cable Limitations Cat 5 and up to 100m Converter Fiber Cable Limitations Multi mode Half duple...

Page 15: ...s causes the remote TP node link to fail LED also shows the link failure on both TP and fiber ports Refer to Figure 4 1 shown below for the normal status when the link succeeds Also refer to Figure 4...

Page 16: ...own this capability in pairs Furthermore both LFP converters should be supplied only by the same manufacturer vender The connection coming from LFP converters with odd models or non LFP converters wi...

Page 17: ...the problem occurs the components involved in the problem any particular application that when used appears to create the problem or make it worse 5 2 Shipping and Packaging If you need to transport o...