4.2 DIP SWITCHES 

 
The DIP switches enable you to configure the CO/CPE and TCPAM/Rate preset. These settings are applied when the device powers on, and 
they cannot be changed while the device is powered on. Keep this in mind if you plan on adjusting these settings later remotely, as the DIP 
switch settings at boot will always take priority.
To disable the DIP switches: 
1. Power off the device.
2. Set all DIP switches to OFF.
To enable the DIP switches: 
1. Power off the device.
2. Set DIP switch #1 to Central Office or Customer Premise. When connecting two Ethernet Extenders back to back, one needs to be 
configured as Central Office, and the other Customer Premise:

Š

Š

OFF = Central Office

Š

Š

ON = Customer Premise

3. Set DIP switches #2–5 to a TCPAM/Rate Preset. When connecting two Ethernet Extenders back to back, their speeds should be 
configured to match.
4. Set DIP switches #6–8 to OFF. These are reserved for future use.

TABLE 4-1. DIP SWITCHES

#2

#3

#4

#5

TCPAM/RATE PRESET

ON

ON

ON

ON

TCPAM 16/32 Autorate

ON

ON

ON

OFF

TCPAM 64/128 Autorate

ON

ON

OFF

ON

TCPAM-4 192 kbps

ON

ON

OFF

OFF

TCPAM-4 2496 kbps

ON

OFF

ON

ON

TCPAM-8 192 kbps

ON

OFF

ON

OFF

TCPAM-8 5056 kbps

ON

OFF

OFF

ON

TCPAM-16 192 kbps

ON

OFF

OFF

OFF

TCPAM-16 3840 kbps

OFF

ON

ON

ON

TCPAM-32 768 kbps

OFF

ON

ON

OFF

TCPAM-32 5696 kbps

OFF

ON

OFF

ON

TCPAM-64 192 kbps

OFF

ON

OFF

OFF

TCPAM-64 12736 kbps

OFF

OFF

ON

ON

TCPAM-128 256 kbps

OFF

OFF

ON

OFF

TCPAM-128 15296 kbps

OFF

OFF

OFF

ON

Reserved

OFF

OFF

OFF

OFF

Disable DIP switches

Summary of Contents for LB510A-R3

Page 1: ...24 7 TECHNICAL SUPPORT AT 1 877 877 2269 OR VISIT BLACKBOX COM ETHERNET EXTENDER 4 PORT USER MANUAL LB510A R3 P o w e r L i n e 1 L i n e 2 ETH 3 ETH 2 ETH 1 ETH 0 ...

Page 2: ...us LEDs 9 4 CONFIGURATION 10 4 1 Options 10 4 2 DIP Switches 11 5 WIZARD INTERFACE 12 5 1 Connect with Web GUI 12 6 CLI OPERATION AND CONFIGURATION 16 6 1 Connect with SSH 16 6 2 Change the IP Address 16 6 3 Change the Default Username 16 6 4 Save the Configuration 16 6 5 DSL Commands 16 APPENDIX A REGULATORY INFORMATION 19 A 1 EMC 19 A 2 Safety 19 A 3 PSTN Regulatory 19 A 4 FCC Part 68 ACTA State...

Page 3: ...evice should be within 10 feet 3 meters of the device should be easily accessible and protected by a circuit breaker If an AC power adapter is used ensure that the power cable used meets all applicable standards for the country in which it is to be installed and that it is connected to a grounded wall outlet Hazardous network voltages are present in WAN ports regardless of whether power to the uni...

Page 4: ...ors 4 RJ 45 Fast Ethernet 10 100 BASE T 1 RJ 45 G SHDSL port for EFM transmission 1 or 2 pair 1 barrel connector for power Indicators 1 Power LED 1 Line 1 1 Line 2 2 ETH3 2 ETH2 2 ETH1 2 ETH0 2 WAN Link LAN 8 Ethernet 4 Link Act User Controls 1 Reset button Dimensions 1 52 H x 5 00 W x 4 7 D 3 9 x 12 7 x 11 9 cm Weight 2 0 lb 1 0 kg Power Power Supply External 90 260 VAC 50 60 Hz Universal Input 5...

Page 5: ...TINUED SPECIFICATIONS SPECIFICATION DESCRIPTION Management Switching and Quality of Service IEEE 802 1D 802 1Q 802 1P Link Scheduling DHCP Client Server Relay SNMP v1 v2 v3 Telnet SSH RS 232 HTTP HTTPS Provisioning TFTP HTTP HTTPS file management Compliance FCC Part 15A CE Mark per EMC directive 89 336 EEC and Low Voltage Directive 73 23 EEC ...

Page 6: ...o 15 3 Mbps over a single pair of wires If you need even more bandwidth the LB510A R3 can bond as many as two pairs 4 wires for up to 30 Mbps 2 2 WHAT S INCLUDED Your package should include the following items If anything is missing or damaged contact Black Box Technical Support at 877 877 2269 or info blackbox com LB510A R3 Ethernet Extender 4 Port External power supply 2 3 HARDWARE DESCRIPTION 2...

Page 7: ...andshake mode looking for a remote signal Blinking fast Port is in training mode active communication with remote ETH3 ETH0 LEDs ON Port is linked OFF Data is passing over the port 2 3 2 BACK PANEL Figure 2 2 shows the back panel of the Ethernet Extender Table 2 2 describes its components Reset Power Reset Button Ethernet Ports 0 3 0 0 DSL Port Eth3 Eth2 Eth1 Eth0 DSL 5V 1A FIGURE 2 2 BACK PANEL T...

Page 8: ...The Ethernet Extender has a two wire interface Observe the signal pin relationship on the LB510A R3 s Line interface jack for each pair in Figure 3 1 FIGURE 3 1 RJ 45 TWISTED PAIR LINE INTERFACE 3 2 CONNECT THE ETHERNET INTERFACE The Ethernet Extender has four unshielded RJ 45 auto MDIX 10 100BASE T interfaces These are designed to connect directly to a 10 100BASE TX network You may connect this p...

Page 9: ...w TABLE 3 1 FRONT PANEL LEDS NUMBER IN FIGURE 2 1 LED INDICATOR DESCRIPTION 1 Power LED LED turns on when power is supplied to the unit LED is off when no power is supplied to the unit 2 On site Pair LEDs One LED for each port OFF Port is configured as down ON Port is in data mode Blinking slowly Port is in handshake mode looking for a remote signal Blinking fast Port is in training mode active co...

Page 10: ...methods for some settings This will be problematic if you need to change these settings remotely The factory installed configuration is shown below context ip ROUTER interface LAN ipaddress 192 168 200 10 24 ipaddress DHCP dhcp context switch group DEFAULT bind interface ROUTER LAN no shutdown interface ETHERNET _ 0 _ 0 interface ETHERNET _ 0 _ 1 interface ETHERNET _ 0 _ 2 interface ETHERNET _ 0 _...

Page 11: ...k to back one needs to be configured as Central Office and the other Customer Premise OFF Central Office ON Customer Premise 3 Set DIP switches 2 5 to a TCPAM Rate Preset When connecting two Ethernet Extenders back to back their speeds should be configured to match 4 Set DIP switches 6 8 to OFF These are reserved for future use TABLE 4 1 DIP SWITCHES 2 3 4 5 TCPAM RATE PRESET ON ON ON ON TCPAM 16 ...

Page 12: ...ons predating Internet Explorer 9 0 browser are not compatible with the LB510A R3 5 1 CONNECT WITH WEB GUI 1 Connect the Ethernet cable 2 Connect the power supply 3 Connect via web browser to the default address 192 168 200 10 4 Log in with the default username admin without a password Once the network connection is established you will be able to reach the LB510A R3 Web GUI Log into the Web GUI u...

Page 13: ...s selected you will have the options of supported set ups as shown in Figure 5 3 Click on LB510A R3 Basic Setup FIGURE 5 3 CHOOSE WIZARD Clicking on the LB510A R3 Basic Setup will bring up the most common configurations used on the Ethernet Extender Figure 5 4 depicts options to configure the extender through the Basic Setup wizard FIGURE 5 4 BASIC SETUP ...

Page 14: ...mise Equipment CPE CO is typically used at the network CPE is typically used at the remote device or remote network Service Mode Configures the number of pairs wires you want to use The extender will default to the maximum number of wires available on your Extender 2 wire Annex Consult Black Box Technical Support at 877 877 2269 or info blackbox com before changing this setting Line Rate Configura...

Page 15: ...ER 5 WIZARD INTERFACE When you choose the save and reboot option a prompt will ask you to confirm If the configuration is correct select Yes as shown in Figure 5 6 FIGURE 5 6 CONFIRMATION SCREEN Typically the time to reboot and re establish a DSL link so the extender can pass traffic will be less than 2 minutes ...

Page 16: ...er node ctx ip router interface LAN node if ip router LAN no ipaddress 192 168 200 10 24 node if ip router LAN ipaddress new address new mask 6 3 CHANGE THE DEFAULT USERNAME The default username will be removed once a new one is created Follow the command sequence below node enable node configure node cfg superuser username password password 6 4 SAVE THE CONFIGURATION Follow the command sequence b...

Page 17: ...PAM64 and 15 3 Mbps TCPAM128 per pair node prt dsl 0 0 tcpam auto 16 32 auto 64 128 16 32 64 128 SIGNAL TO NOISE RATIO Configures the acceptable noise margin for adaptive rate SNR is the relative strength of the DSL signal to Noise ratio 6 dB is generally the lowest dB recommended in order for the modem to be able to synch Generally speaking as overall bandwidth increases your signal to noise rati...

Page 18: ... THE TECH TO US LIVE 24 7 TECHNICAL SUPPORT 1 877 877 2269 CHAPTER 6 CLI OPERATION AND CONFIGURATION EXIT Goes back to parent mode node prt dsl 0 0 exit SHOW Displays all the configured options of the LB510A R2 DSL port s node cfg show port dsl 0 0 ...

Page 19: ...lephone network the telephone company will notify you in advance that temporary discontinuance of service may be required But if advance notice isn t practical the telephone company will notify the customer as soon as possible Also you will be advised of your right to file a complaint withthe FCC if you believe it is necessary The telephone company may make changes in its facilities equipment oper...

Page 20: ...elephone lines and internal metallic water pipe system are connected together This protection may be particularly important in rural areas A 6 RADIO AND TV INTERFERENCE FCC PART 15 This equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception ...

Page 21: ...ve consequential or cost of cover damages resulting from any errors in the product information or specifications set forth in this document and Black Box Corporation may revise this document at any time without notice B 2 TRADEMARKS USED IN THIS MANUAL Black Box and the Black Box logo type and mark are registered trademarks of Black Box Corporation Any other trademarks mentioned in this manual are...

Page 22: ...__________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ ____________________________________________...

Page 23: ...__________ ________________________________________________________________________________________________ _______________________________________________________________________________________________ __________________________________________________________________________________________________ _________________________________________________________________________________________________...

Page 24: ...NEED HELP LEAVE THE TECH TO US LIVE 24 7 TECHNICAL SUPPORT 1 877 877 2269 COPYRIGHT 2018 BLACK BOX CORPORATION ALL RIGHTS RESERVED LB510A R3_USER_REV1 PDF ...

Reviews: