Black Box®LB1350A/LB1351A
25
Basic ports' status
:
#
Type Link Duplex AutoNego Rate Connected
================================================
1
TP Off FDX Disabled 100M Yes
2
TP Off n/a Enabled n/a Yes
3
TP Off n/a Enabled n/a Yes
4
FO Off FDX ---- 100M Yes
================================================
Basic device status
:
---------
-----------
VLAN: enabled
Temperature: 39C
figure 6-3 - basic status
Basic status
This status includes the basic ports’ status and the basic device status.
Basic port’s status
gives the following data about each port:
•
Port number
•
Interface type (TP/FO)
•
Link status (On/Off)
•
Duplex mode (FDX/HDX)
•
Auto-Negotiation mode (enabled/disabled)
•
Data rate (10/100M)
•
Connection mode (connected/disconnected)
The
basic device status
includes:
•
VLAN mode (enabled/disabled)
•
Device’s temperature (in centigrade)
Advanced ports' status
:
#
Type Tag: Insert Strip VID | Priority: Port 802.1p TOS User
===============================
|
===============================
1
TP No No 0 | No No No 0
2
TP No No 0 | No No No 0
3
TP No No 0 | No No No 0
4
FO No No 0 | No No No 0
Mgmt No Yes 222 | No No No 0
===============================
|
========
=======================
Advanced device status
:
-----------------------
Test: Off
Priority ratio: Always high
Broadcast: Allow 25% broadcasts
DSCP (63 <- 0): 0x00-00-00-00-00-00-00-00
User priority: code: 0 1 2 3 4 5 6 7
prio: LO LO LO LO HI HI HI HI
figure 6-4
-
advanced status