background image

724-746-5500   |   blackbox.com 

 

Page 3

Category 6 High-Density Feed-Through Patch Panels

We‘re here to help! If you have any questions about your application  

or our products, contact Black Box Tech Support at 

724-746-5500

  

or go to 

blackbox.com

 and click on “Talk to Black Box.”

You’ll be live with one of our technical experts in less than 20 seconds. 

4.  When using the shielded High-Density Feed-Through Patch Panels, make sure to attach the necessary drain wires. Use one 

drain wire for each shielded module on the patch panel. Attach the drain wire in either of the two places as shown in Figure 
3-1. Connect the other end of the drain wire to proper ground.

Figure 3-1. Drain wire installation options for shielded models. 

5. Use cable ties to secure the cables to the cable management bar. See Figure 3-2.

Figure 3-2. Completed installation.

 

 

 

Lower right view

Top left view