Output Commands
:
The following Output Command formats shall be used:
Oxx=<CR>
: Report an output (x) channel configuration.
Device replies with:
Oxx=yy<CR><LF>
Parameters:
x = Output channel (1 - 16)
y = Input channel assigned to selected output channel (0 = OFF)
Oxx=yy<CR>
: Configure an output (x) channel.
Device replies with:
Oxx=yy<CR><LF>
Parameters:
xx = Output channel (1 - 16)
yy = Input channel assigned to selected output channel (0 = OFF)
Preset Commands:
The following Preset Command formats shall be used:
Pxx=<CR>
: Report a preset (x) configuration.
Device replies with:
Pxx=aa,bb,cc,dd,de,ff,gg,hh, ii, jj, kk,ll,,mm,nn,oo,pp<CR><LF>
Parameters:
xx = Preset (0 - 16) – If x = 00, the current (working) configuration
is reported.
aa = Output 1 input selection (0 = OFF)
bb = Output 2 input selection (0 = OFF)
:
pp = Output 16 input selection (0 = OFF)
Pxx<CR>
: Saves current (working) configuration as a preset (xx)
configuration.
Device replies with:
Preset xx Stored! <CR><LF>
Parameters:
xx = Preset (1 - 16)
CHAPTER 3: Setup and Installation
11
.
Pxx=a,b,c,d,e,f,g,h,i,j,k,l,m,n,o,p<CR>
: Configures a preset.
Device replies with:
Preset xx Stored! <CR><LF>
If xx = 00 or if x = a recalled preset, the current working preset is
reported as:
P00=a,b,c,d,e,f,g,h,i,j,k,l,m,n,o,p<CR><LF>
If xx = a stored preset, the new preset configuration will be saved in
preset memory location xx.
Parameters:
xx = Preset (0 - 16)
aa = Output 1 input selection (0 = OFF)
bb = Output 2 input selection (0 = OFF)
:
pp = Output 16 input selection (0 = OFF)
Recall Commands:
The following Recall Command formats shall be used:
Rxx<CR>
: Recall preset (xx) and copy to current working preset.
Device replies with:
P00=a,b,c,d,e,f,g,h,i,j,k,l,m,n,o,p<CR><LF
Parameters:
aa = Output 1 input selection (0 = OFF)
bb = Output 2 input selection (0 = OFF)
:
pp = Output 16 input selection (0 = OFF)
Clear Working Preset
This command will turn all outputs off immediately.
C<CR>
: Clear working preset
Device replies with: P00=00,00,00,00,00,00,00,00,
00,00,00,00,00,00,00,00<CR><LF>
12