3. Setup and Installation 

 
3.1 Cabling Considerations 
 

• We recommend mounting and connecting all cabling to the CAT5 Multi VGA 
System components before applying power. 
• Make sure that the CAT5 cable you intend to use has been tested to comply 
with the TIA/EIA 568B wiring specification. 

 
3.2 Making the Connections 
 

3.2.1 C

ONNECTIONS AND 

S

ETUP IN 

G

ENERAL 

 

Refer to Figure 3-1 for cabling information. See Appendix A for cable pinning 
information. 
 
1. Connect an RJ-45 cable from a CAT5 Multi Video System transmitter unit  into 
any port labeled SOURCE. 

NOTE 

It is recommended to maintain cable lengths as equal as possible from each 

transmitter unit to the switch. This is due to all adjustments for cable length 

compensation are done on receiver units. Switching between inputs with unequal 

cable lengths may cause display images to change due to incorrect cable 

compensation settings on the receiver. 

 
2. Connect  RJ-45 cables from CAT5 Multi Video System receiver units into the 
ports labeled  OUTPUT. 

 

3. Connect the power cable to the unit. 
 
4. If applicable, attach a serial control cable to the 5 position phoenix connecter 
(reference Appendix A for pinout information. 
 
5. If using  external serial control see Section XX for serial configuration. 

 

 

CHAPTER 2: Introduction 

Figure 3-1. Switch connections on the AC1051A. 

 

NOTE 

It is recommended to maintain cable lengths as equal as possible from each 

transmitter unit to the switch. This is due to all adjustments for cable length 

compensation are done on receiver units. Switching between inputs with unequal 

cable lengths may cause display images to change due to incorrect cable 

compensation settings on the receiver. 

 

Figure 3-2.  Front Panel Buttons on the AC1051A. 

 

CAT5 MULTI VGA SYSTEM 

Summary of Contents for AC1051A

Page 1: ...der toll free in the U S Call 877 877 BBOX outside U S call 724 746 5500 FREE technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation...

Page 2: ...EU DECLARATION OF CONFORMITY 1 NORMAS OFICIALES MEXICANAS NOM ELECTRICAL SAFETY STATEMENT INSTRUCCIONES DE SEGURIDAD 1 Todas las instrucciones de seguridad y operaci n deber n ser le das antes de que...

Page 3: ...A El cable de poder o el contacto ha sido da ado u B Objectos han ca do o l quido ha sido derramado dentro del aparato o C El aparato ha sido expuesto a la lluvia o D El aparato parece no operar norm...

Page 4: ...x 6 8 D 8 7 x 43 6 x 17 2 cm Weight 2 6 lb 1 2 kg CHAPTER 1 Specifiations 5 2 Introduction 2 1 Overview The CAT5 Multi 16 x 16 Matrix Switch switches signals over Category 5 Cable to any number of 16...

Page 5: ...inputs with unequal cable lengths may cause display images to change due to incorrect cable compensation settings on the receiver 2 Connect RJ 45 cables from CAT5 Multi Video System receiver units in...

Page 6: ...he Recall key Press the Input key number 1 16 that the Preset was stored under Press the Enter key To start over Press the Cancel key CHAPTER 3 Setup and Installation 9 3 2 4 SERIAL CONTROL The Cat5 M...

Page 7: ...ce replies with Preset xx Stored CR LF Parameters xx Preset 1 16 CHAPTER 3 Setup and Installation 11 Pxx a b c d e f g h i j k l m n o p CR Configures a preset Device replies with Preset xx Stored CR...

Page 8: ...oblems In most cases nearly every issue with the CAT5 Multi VGA System can be resolved by checking the CAT5 termination and making sure that it s pinned to the TIA EIA 568B wiring specification Howeve...

Page 9: ...Appendix A Cabling Pinouts Table A 1 Captive Screw Connector APPENDIX A Cabling Pinouts Pin Signal 1 Tx 2 Not used 3 Rx 4 Not used 5 Ground 15 16 CAT5 MULTI VGA SYSTEM...

Page 10: ...NOTES 17 Copyright 2005 Black Box Corporation All rights reserved 1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746...

Reviews: