background image

7

2- TO 4-WIRE HYBRID CONVERTER

3. Installation

3.1 What to Do First

The Converter is designed to work with 2-wire leased-line modems with a transmit
level of 0 dBm. Make sure that your modem is set at this level before you install the
Converter. For instructions on setting the transmit level, refer to your modem’s
user manual or call the modem’s manufacturer.

3.2 Installing the Converter

The Converter is designed to operate with 600-ohm VF leased lines only. Follow
these steps to install the Converter:

1. Connect the two-wire modem to the terminal screw block or the RJ-11

connector on the 2W side of the Converter.

2. Connect the four-wire line Transmit and Receive pairs to the 4W terminal

screw blocks marked TD and RD, or connect the line to the RJ-11 modular
jack marked 4W. Figure 3-1 shows a schematic diagram of the connections.

Figure 3-1. 2- and 4-wire connections on the Converter.

NOTE

You can mix terminal and jack connections, if required. Both the two-
wire and four-wire connections are not sensitive to polarity, so you can
connect either terminal to Tip or Ring.

2
3
4
5

3
4

2/4 WIRE

HYBRID

Summary of Contents for 2- to 4-Wire Hybrid Converter

Page 1: ...E technical support 24 hours a day 7 days a week Call 724 746 5500 or fax 724 746 0746 Mailing address Black Box Corporation 1000 Park Drive Lawrence PA 15055 1018 Web site www blackbox com E mail inf...

Page 2: ...ment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference Changes or...

Page 3: ...El aparato el ctrico debe ser montado a la pared o al techo s lo como sea recomendado por el fabricante 8 Servicio El usuario no debe intentar dar servicio al equipo el ctrico m s all a lo descrito en...

Page 4: ...existir una antena externa deber ser localizada lejos de las lineas de energia 16 El cable de corriente deber ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo 17 Cuid...

Page 5: ...4 2 TO 4 WIRE HYBRID CONVERTER Contents Chapter Page 1 Specifications 5 2 Introduction 6 3 Installation 7 3 1 What to Do First 7 3 2 Installing the Converter 7 4 Application 9...

Page 6: ...Transparent CE Approval Yes Impedance 600 ohms Through Signal Loss Less than 6 dBm Hybrid Rejection Greater than 30 dBm Interface 4 wire VF circuit Connectors 2 RJ 11 2 screw terminals Power From att...

Page 7: ...Converter connects to the modem and the line via your choice of RJ 11 or screw terminal connectors You can also mix RJ 11 and screw terminal connections if necessary Both the 2 wire and 4 wire connec...

Page 8: ...ines only Follow these steps to install the Converter 1 Connect the two wire modem to the terminal screw block or the RJ 11 connector on the 2W side of the Converter 2 Connect the four wire line Trans...

Page 9: ...8 2 TO 4 WIRE HYBRID CONVERTER 3 Your Converter is installed and ready for operation...

Page 10: ...9 2 TO 4 WIRE HYBRID CONVERTER 4 Application Figure 4 1 shows a typical application of the 2 to 4 Wire Hybrid Converter Figure 4 1 Typical application of the Converter...

Page 11: ...1000 Park Drive Lawrence PA 15055 1018 724 746 5500 Fax 724 746 0746 Copyright 1998 Black Box Corporation All rights reserved...

Reviews: