FUNCTION BUTTONS (FROM LEFT TO RIGHT):

Battery Type

(Step 1) — allows the user to select Wet, Gel or AGM type of battery

for efficient and safe charge. Most automotive batteries are Wet batteries. Refer to the
battery manufacturer’s specifications for battery type.

2/10/25A AMP (Charge Rate Selector) 

(Step 2) — allows the user to select

the charge rate based on battery size. This selection and the actual battery charge
rate are monitored by the microprocessor. The charger will stop charging if the rate
is too fast or too slow for the battery size or condition.

75 AMP Engine Start — 

places the charger in an engine start sequence. This

button will not be activated unless the charger is in the 25 amp charge mode; set the
2/10/25 AMP button to 25 amps first to activate this button.

Battery Recondition —

is an automatic mode that, once started, continues for 24

hours and then stops. A series of electrical pulses breaks the crystalline form of lead
sulfate to return these chemicals into useful battery electrolytes. More than 24 hours
may be needed to restore. Periodic reconditioning is recommended to maintain a
battery's optimum performance. However, if 5 cycles does not improve battery
performance, discontinue and recycle the battery. 

Battery Voltage (Alternator Voltage Check) —

is a quick check that measures

the battery voltage. This check is repeated at various electrical load levels and the
tests allow the user to determine if the alternator can keep up with the loads.

INDICATOR:

Large (.375”) 3-Character Digital Display

in the upper left of the control panel

indicates the various conditions and/or status codes:

CONTROL PANEL

DIGITAL READOUT

CIRCULATING PATTERN

2

Stage Two —

Absorption Charge maintains the maximum possible charge at a

constant, safe, predetermined voltage. During this phase, the charging voltage
remains constant, while the actual charging current is reduced to allow for the
maximum proper internal chemical energy transfer.  At the end of Stage 2, the charger
will automatically move into Stage 3 charge mode.

Stage Three —

Top-Off Charge — voltage is automatically maintained and

reduced to a predetermined level while current is adjusted for a safe, effective battery
charge. At the conclusion of Stage 3, the unit will BEEP signaling the completion of
the charging cycle.
The Automatic Float Charge feature is ideal for maintaining a battery. It automatically
tops off battery as needed to keep battery fully charged all the time.

FEATURES

• This unit has three charge rate settings, accessed by the 2/10/25 AMP button:

a) 2 amps: smaller batteries, such as in lawn mowers, snowmobiles, motorcycles,

etc.

b) 10 amps: mid-sized batteries, such as in small cars
c) 25 amps: automobiles and light trucks

• 75 amp engine start
• Automatic Temperature Compensation
• Battery type selection
• Digital diagnostics
• Alternator voltage and battery voltage check
• Digital display shows charge rate, operating mode, fault codes and FUL when

charged

• 1-minute engine start
• 3-stage high-frequency switch mode automatic rapid charging
• Spark resistant reverse polarity and short circuit protection for user
• Built-in battery reconditioning (desulfate)
• Lightweight, high-efficiency design
• Internal short circuit protection
• Cables and clamps self-stored
• Reverse polarity indication
• Microprocessor control (Digital Smart Control)/High frequency power
• Compensates for low AC from extension cord use
• Equalization function

VEC1095ABD_Manual_050205  5/5/05  6:35 PM  Page 2

Summary of Contents for VEC1095ABD

Page 1: ...During the warranty period manufacturer will be responsible for the return shipping charges LIMITATIONS This warranty does not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents damage during shipping to our service facility alterations unauthorized use or...

Page 2: ...G NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY 2 To reduce risk of battery explosion follow these instructions and those published by the battery manufacturer and manufacturer of any equipment you intend to use in vicinity of battery Review cautionary markings on these products ...

Page 3: ...s for length of charge information Follow these steps when the battery has been removed from a vehicle A spark near the battery may cause an explosion To reduce risk of a spark near the battery 1 Check polarity of battery posts The POSITIVE post marked POS P usually has a larger diameter than the NEGATIVE battery post marked NEG N 2 Attach a 24 inch minimum length 6 AWG insulated battery cable to ...

Page 4: ...codes CONTROL PANEL DIGITAL READOUT CIRCULATING PATTERN 2 Stage Two Absorption Charge maintains the maximum possible charge at a constant safe predetermined voltage During this phase the charging voltage remains constant while the actual charging current is reduced to allow for the maximum proper internal chemical energy transfer At the end of Stage 2 the charger will automatically move into Stage...

Page 5: ... displays 0 0 during self test or charging stage changes 3 Pressing the 2 10 25 AMP button again advances charging rate to 10 amps and pressing once more advances charging rate to 25 amps Pressing the button again will turn OFF the charger output and the Display will show 000 This selection and actual battery charge rate are monitored by the microprocessor and the unit will stop charging if the se...

Page 6: ... battery remains in a discharged condition over a longer period of time the lead sulfate changes to a hard crystalline form making a full charge difficult to achieve Reconditioning may save a sulfated battery BATTERY RECONDITION MODE should only be used with 10 Amp Hour Ah or larger capacity lead acid batteries Charge the battery to be treated for 20 minutes 6 As the battery nears full charge capa...

Page 7: ...ted cells F01 open cells F03 or battery too low to accept a charge F02 and to ensure the battery can take a charge If code F03 is displayed change to the BATTERY RECONDITION MODE Remove or disconnect the vehicle s battery when reconditioning 1 Make sure the charger is in initiation state with a circulating pattern on the display or in charge OFF mode with 000 on the display If not press 2 10 25 AM...

Page 8: ...oning and equalizing we recommend taking your battery to a certified automotive service center for evaluation F04 Overtime Condition Appears when charging time exceeds 18 hours You may be using a charge current rate too low for a large battery Select higher charge rate to charge the battery F05 Overheated Condition The ventilation grill that prevents the air from flowing in and out of the charger ...

Reviews: