Important Cable Information

Substantial power loss and reduced battery operating time results from inverters installed with cables that

are not able to supply full power. Symptoms of low battery power can result from cables that are either

excessively long or an insufficient gauge. Marine installations are also subjected to vibration and stresses

that exceed those of other mobile installations. Therefore, the installer/operator should be especially

aware of the requirements to maintain secure, tight, water-resistant electrical connections and to provide

for strain relief for DC cables and appliance wiring. Cable insulation must be the appropriate type for

the environment.

SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS 

To ensure reliable service, your power inverter must be installed and used properly. Please read the

installation and operating instructions thoroughly prior to installation and use. Pay particular attention to

the WARNING and CAUTION statements in this manual. The CAUTION statements advise against

certain conditions and practices that may result in damage to your inverter. The WARNING statements

identify conditions or practices that may result in personal injury.

Read All Instructions Before Using This Power Inverter!

WARNINGS
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION OR INJURY:
• Do not connect to AC distribution wiring.
• Remove appliance plug from outlet strip or turn off inverter before working on the

appliance. Multiple outlet power strips with switches and circuit breakers only
interrupt power to the "hot" receptacle terminals. The "neutral" terminals remain
powered with respect to the "ground" terminals.

• NOT approved for ignition protected areas. Do not make any electrical connections

or disconnections in areas designated as IGNITION PROTECTED.

• This is not a toy — keep away from children.
• This equipment employs components that tend to produce arcs or sparks. DO NOT

install in compartments containing batteries or flammable materials.

• Use this unit in properly ventilated areas ONLY.
• Do not open — there are no user-serviceable parts inside.
• Do not insert foreign objects into the outlet.
• Do not expose the unit to water, rain or snow.

CAUTIONS
• Always inspect battery supply connections and cables to ensure they are tight and

that cable insulation is not damaged.

• Do not use with positive ground electrical systems (the majority of modern

automobiles, RVs, trucks and boats are negative ground). Reverse polarity
connection will result in a blown fuse and may cause permanent damage to the
inverter and will void warranty.

• This inverter will not operate high wattage appliances or equipment that produce

heat, such as hair dryers, microwave ovens and toasters.

• Grounding the Neutral will cause the inverter to shut down. Do not operate this

inverter if it is wet. Do not install in engine compartment — install in a well
ventilated area.

• This inverter has not been not tested for use with medical devices.
• Do not attempt to install or operate this unit while operating a motor vehicle.
FOR USAGE ABOVE 100 WATTS:
• Use battery clips ONLY.
• DO NOT use the DC accessory plug or the fuse will open.

VEC1045_46_47_BD_Manual  4/28/05  5:16 PM  Page ii

Summary of Contents for VEC1045BD

Page 1: ... Thermal Shutdown Automatic Wave Form Modified Sine Wave MSW Output Connection North American Standard Receptacles Input Fuses Internal Input Cables Battery cable with ring connector Additional Protection Overload over voltage overheating Trouble Indication Possible Cause Suggested Remedy No AC output DC input is out of range Check battery voltage red LED lit Excessive load Turn unit off Reduce th...

Page 2: ... strips with switches and circuit breakers only interrupt power to the hot receptacle terminals The neutral terminals remain powered with respect to the ground terminals NOT approved for ignition protected areas Do not make any electrical connections or disconnections in areas designated as IGNITION PROTECTED This is not a toy keep away from children This equipment employs components that tend to ...

Page 3: ...other than accessories may be returned postage prepaid to manufacturer Any defective product other than accessories that is returned to manufacturer within 30 days of the date of purchase will be replaced free of charge If such a product is returned more than 30 days but less than two years from the purchase date manufacturer will repair the unit or at its option replace it free of charge If the u...

Page 4: ...VE and the side contact is NEGATIVE Connect the inverter to the power source by inserting the DC accessory outlet plug firmly into the accessory outlet of a vehicle or other DC power source CAUTIONS Connect directly to power source when operating above 100 watts Do not use with positive ground electrical systems Reverse polarity connection will result in a blown fuse and may cause permanent damage...

Page 5: ...nal of the DC power source battery 8 Insert a fuse appropriate to the inverter in the fuse holder 4 Notes Most vehicle accessory outlet circuits have fuses rated at 15 to 20 amps or greater To operate at full wattage either use the battery clip cable supplied or directly wire to the power source with user supplied wire and fuse The majority of modern automobiles RVs and trucks are negative ground ...

Page 6: ...N Loose connectors may cause overheated wires and melted insulation Check to make sure you have not reversed the polarity Damage due to reversed polarity is not covered by our warranty Connection To Load The Power Inverter is equipped with dual standard North American AC power receptacles Plug the cord from the equipment you wish to operate into the AC receptacle s Make sure the combined load requ...

Reviews: