7

WARNING: BURST HAZARD

• The inflator is capable of inflating up to 120 pounds per square inch (psi) pressure. To avoid over-inflation, carefully follow

instructions on articles to be inflated. Never exceed recommended pressures. Bursting articles can cause serious injury.

• Always check pressure with the pressure gauge.
• Never leave the inflator unattended while in use.

CAUTION: RISK OF PROPERTY DAMAGE

Do not operate inflator continuously for extended periods of time (approximately 10 minutes, depending on ambient
temperatures), as it may overheat. In such event, inflator will automatically shut down. Immediately turn OFF the Inflator Power
Switch. Restart after a cooling down period of approximately 10 minutes.

Inflating Tires or Products With Valve Stems

1. Place connector (chuck) on valve stem.
2. Ensure connector is pushed on to valve stem as far as possible before closing thumb latch.
3. Make sure latch is secure.
4. Turn ON the Inflator Power Switch.
5. Check pressure with the pressure gauge.
6. When desired pressure is reached, open thumb latch and remove connector from valve stem.
7. Turn OFF Inflator Power Switch.
8. Allow unit to cool before storing away.
9. Store inflator hose and tire fitting in storage compartment.

Inflating Other Inflatables Without Valve Stems

Inflation of other items requires use of one of the adapters (nozzles).

1. Select the appropriate nozzle, located on the inside back cover.
2. Insert appropriate adapter (i.e. needle) into connector (chuck) and close thumb latch.
3. Small items such as volleyballs, footballs, etc. inflate very rapidly.
4. Insert adapter (i.e., needle) into item to inflate to appropriate pressure.
5. Turn ON the Inflator Power Switch — inflate to desired pressure or fullness.
6. Remove adapter.
7. Switch the Inflator Power Switch OFF.
8. Recharge the unit before storing away.

CARE AND MAINTENANCE

Battery Replacement

It is recommended that the unit be returned to a Black & Decker Service Center. Contact Customer Service, toll-free, at 
1-800-544-6986 to locate a Service Center near you.

Battery Disposal

Contains a maintenance-free, sealed, non-spillable, lead acid battery, which must be disposed of
properly. Recycling is required — contact your local authority for information. Failure to comply with
local, state and federal regulations can result in fines or imprisonment. For more information on
recycling this battery, call toll-free 1-800-822-8837.

WARNINGS

Do not dispose of this unit in fire as batteries inside this product may explode or leak.
Do not expose the unit containing a battery to fire or intense heat as it may explode.
Before disposing of the battery, protect exposed terminals with heavy-duty electrical tape to prevent shorting (shorting can
result in injury or fire).

ACCESSORIES

Recommended accessories for use with your tool are available from your local dealer or authorized service center. If you need
assistance regarding accessories, please call: 1-800-544-6986.

WARNING: 

The use of any accessory not recommended for use with this tool could be hazardous.

SERVICE INFORMATION

All Black & Decker Service Centers are staffed with trained personnel to provide customers with efficient and reliable power tool
service. Whether you need technical advice, repair, or genuine factory replacement parts, contact the Black & Decker location
nearest you. To find your local service location, refer to the yellow page directory under "Tools—Electric" or call: 

1-800-544-

6986

or visit 

www.blackanddecker.com

.

6

Jump-Starter

This Jump-Starter is equipped with an ON/OFF Power Switch. Once the connections are properly made, turn the switch ON to
jump-start the vehicle.

1. Turn OFF vehicle ignition and all accessories (radio, A/C, lights, connected cell phone chargers, etc.). Place vehicle in “park”

and set the emergency brake. 

2. Make sure the Jump-Starter Power Switch is turned to OFF.
3. Remove jumper clamps from clamp tabs. Connect the red clamp first, then the black clamp. 
4. Procedure for jump-starting a NEGATIVE GROUNDED SYSTEM (negative battery terminal is connected to chassis) (MOST

COMMON)
4a. Connect positive (+) red clamp to vehicle battery’s positive terminal.
4b. Connect negative (–) black clamp to chassis or a solid, non-moving, metal vehicle component or body part. Never clamp

directly to negative battery terminal or moving part.

5. Procedure for jump-starting POSITIVE GROUND SYSTEMS

Note:

In the rare event that the vehicle to be started has a Positive Grounded System (positive battery terminal is
connected to chassis), replace steps 4a and 4b above with steps 5a and 5b, then proceed to step 6.

5a. Connect negative (–) black clamp to vehicle battery’s negative terminal.
5b. Connect positive (+) red clamp to vehicle chassis or a solid, non-moving, metal vehicle component or body part. Never

clamp directly to Positive battery terminal or moving part.

6. When clamps are connected properly, turn the Jump-Starter Power Switch to ON.
7. Turn ON the ignition and crank the engine in 5-6 second bursts until engine starts.
8. Turn the Jump-Starter Power Switch back to the OFF position.
9. Disconnect the negative (–) engine or chassis clamp first, then disconnect the positive (+) battery clamp.

FOLLOW ALL SAFETY INSTRUCTIONS FOUND IN THIS MANUAL.

CAUTIONS: RISK OF PROPERTY DAMAGE

• If the connections to the battery’s POSITIVE and NEGATIVE terminals are incorrect, the Reverse Polarity Indicator will light

(red) and the unit will sound a beep.  Disconnect clamps and reconnect to battery with correct polarity.

• If vehicle fails to start, turn OFF the ignition, turn OFF the Jump-Starter Power Switch, disconnect the jump-start system’s

leads and contact a qualified technician to investigate why the engine did not start.

• Recharge this unit fully after each use.

WARNINGS

• Jump-Starter Power Switch should be off prior to jump-starting.
• This power system is to be used ONLY on vehicles with 12 volt DC battery systems.
• Never touch red and black clamps together — this can cause dangerous sparks, power arcing, and/or explosion.
• Vehicles that have on-board computerized systems may be damaged if vehicle battery is jump-started. Before jump-starting this

type of vehicle, read the vehicle manual to confirm that external-starting assistance is advised.

• Excessive engine cranking can damage the vehicle‘s starter motor. If the engine fails to start after the recommended number of

attempts, discontinue jump-start procedure and look for other problems that need to be corrected.

• After use, turn the Jump-Starter Power Switch OFF.
• Replace worn or defective parts immediately — contact the Customer Service Department toll free 1-800-544-6986.

12 VOLT DC PORTABLE POWER SUPPLY

This portable power source is also for use with all 12 volt DC accessories equipped with a male accessory outlet plug and are
rated up to 5 amps.

1. Lift up the cover of the unit ‘s 12 volt DC outlet.
2. Insert the 12 volt DC plug from the appliance into the 12 volt accessory outlet on the unit. 

DO NOT EXCEED A 5 AMP LOAD.

3. Switch on the appliance and operate as usual.
4. Periodically press the battery charge level pushbutton to check battery status.

EMERGENCY AREA LIGHT

The area light is controlled by the Area Light Power Switch on the front panel of the unit. Make sure the lamp is turned OFF
when the unit is being recharged or stored. 

PORTABLE INFLATOR

The built-in 12 volt DC inflator is the ultimate inflator for all vehicle tires, trailer tires and recreational inflatables. Three different
sized nozzles are supplied. Each nozzle will clip on the end of the standard tire valve connector located at the free end of the
inflator hose. The inflator nozzles are stored inside the hose hatch. The inflator hose with tire fitting is stored in a retaining
channel between the jumper cable channels on the rear of the unit. The ON/OFF Switch is located on the back of the Main Unit.
The inflator can operate long enough to fill up to 3 average sized tires before the battery must be recharged.
The inflator may be used by removing the air hose from the storage hatch and if required, fitting an appropriate nozzle to the air
hose. An On/Off switch located on the back of the unit controls the power to the inflator and the gauge light. Refer to the
“Controls and Indicators” section on page 5 for locations of inflator hose and nozzle storage hatch. Return hose to the storage
compartment after use.

JU500CB ManualENSP 051608.qxp  5/16/2008  9:41 AM  Page 6

Summary of Contents for JU500CB

Page 1: ...a política de devolución del comercio generalmente entre 30 y 90 días posteriores a la venta Le pueden solicitar comprobante de compra Consulte en el comercio acerca de la política especial sobre devoluciones una vez excedido el plazo establecido La segunda opción es llevar o enviar el producto con flete pago a un Centro de mantenimiento propio o autorizado de Black Decker para su reparación o ree...

Page 2: ...ight red and the unit will sound a beep Disconnect clamps and reconnect to battery with correct polarity Always disconnect the negative Black jumper cable first followed by the positive Red jumper cable except for positive grounded systems 2 SAFETY GUIDELINES DEFINITIONS DANGER Indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING Indicates...

Page 3: ... number of attempts discontinue jump start procedures and look for other problems that may need to be corrected Do not use this jump starter on a watercraft It is not qualified for marine applications Although this unit contains a non spillable battery it is recommended that unit be kept upright during storage use and recharging To avoid possible damage that may shorten the unit s working life pro...

Page 4: ... battery s positive terminal 4b Connect negative black clamp to chassis or a solid non moving metal vehicle component or body part Never clamp directly to negative battery terminal or moving part 5 Procedure for jump starting POSITIVE GROUND SYSTEMS Note In the rare event that the vehicle to be started has a Positive Grounded System positive battery terminal is connected to chassis replace steps 4...

Page 5: ...tions contact the manager of your nearest Black Decker Service Center This product is not intended for commercial use FREE WARNING LABEL REPLACEMENT If your warning labels become illegible or are missing call 1 800 544 6986 for a free replacement SPECIFICATIONS Boost Ampere 500 instantaneous cranking amps Battery Type Sealed high energy density AGM lead acid rechargeable maintenance free 12 volt D...

Page 6: ...vocar la muerte o lesiones graves PRECAUCIÓN Indica una situación de peligro potencial que si no se evita puede provocar lesiones leves o moderadas PRECAUCIÓN Utilizado sin el símbolo de alerta de seguridad indica una situación de peligro potencial que si no se evita puede provocar daños en la propiedad RIESGO DE OPERACIÓN INSEGURA Cuando se utilizan herramientas o equipos siempre se deben respeta...

Page 7: ...PIEL Si el ácido de la batería entra en contacto con la piel enjuáguese inmediatamente con agua luego lávese con agua y jabón Si se presenta enrojecimiento dolor o irritación busque asistencia médica de inmediato OJOS Si el ácido de la batería entra en contacto con los ojos lávese los ojos inmediatamente durante 15 minutos como mínimo y busque asistencia médica de inmediato IMPORTANTE Esta unidad ...

Page 8: ... entrega parcialmente cargada usted debe cargarla completamente antes de usarla por primera vez La carga inicial de CA debe ser de 24 horas Para una duración máxima de la batería recomendamos que el puente auxiliar de arranque se mantenga completamente cargado en todo momento Si se permite que la batería permanezca descargada se acortará su duración Nota Recargar la batería luego de cada uso prolo...

Reviews: