background image

9

WARNING: BURST HAZARD

• The inflator is capable of inflating up to 120 pounds per square inch (psi) pressure. To avoid over-inflation,

carefully follow instructions on articles to be inflated. Never exceed recommended pressures. Bursting articles
can cause serious injury.

• Always check pressure with the pressure gauge.
• Never leave the inflator unattended while in use.

CAUTION: RISK OF PROPERTY DAMAGE

Do not operate inflator continuously for extended periods of time (approximately 10 minutes, depending on
ambient temperatures), as it may overheat. In such event, inflator will automatically shut down. Immediately turn
OFF the Inflator Power Switch. Restart after a cooling down period of approximately 10 minutes.

Inflating Tires or Products With Valve Stems

1.Place connector (chuck) on valve stem.
2.Ensure connector is pushed on to valve stem as far as possible before closing thumb latch.
3.Make sure latch is secure.
4.Turn ON the Inflator Power Switch.
5.Check pressure with the pressure gauge.
6.When desired pressure is reached, open thumb latch and remove connector from valve stem.
7.Turn OFF Inflator Power Switch.
8.Allow unit to cool before storing away.
9.Store inflator hose and tire fitting in storage compartment.

10.Recharge the unit before storing away.

Inflating Other Inflatables Without Valve Stems

Inflation of other items requires use of one of the adapters (nozzles).

1.Select the appropriate nozzle, located on the inside back cover.
2.Insert appropriate adapter (i.e. needle) into connector (chuck) and close thumb latch.
3.Small items such as volleyballs, footballs, etc. inflate very rapidly.
4.Insert adapter (i.e., needle) into item to inflate to appropriate pressure.
5.Turn ON the Inflator Power Switch — inflate to desired pressure or fullness.
6.Remove adapter.
7.Switch the Inflator Power Switch OFF.
8.Recharge the unit before storing away.

CARE AND MAINTENANCE

Charging/Recharging

This product has a sealed lead acid battery that should be kept fully charged. Charge before first use; and

recharge immediately after each use, and every 60 days if not used. Failure to do this may reduce the battery life

dramatically. Refer to the “Charging/Recharging” section of this Instruction Manual.
When the battery is overly discharged and if the green LED is lit when the charger is plugged in, this indicates the

battery is at a high impedance stage. 
In this event, recharge the unit and leave the unit on charge for a period of 48hrs before using the unit. 

Fuse Replacement (DC Accessory Adapter)

1. Remove plug from accessory outlet. Remove the gold cap by turning counter clockwise and lifting off. 
2. Remove center pin and spring. Remove fuse.
3. Replace fuse with same type and size fuse (8 amp). 
4. Replace center pin and spring inside plug.
5. Replace gold cap by turning clockwise.

Battery Replacement/Disposal

It is recommended that the unit be returned to manufacturer for battery replacement. Contact Customer Service,

toll-free, at 1-800-544-6986.

Battery Disposal

Contains a maintenance-free, sealed, non-spillable, lead acid battery, which must be

disposed of properly. Recycling is required — contact your local authority for information.

Failure to comply with local, state and federal regulations can result in fines

or imprisonment. For more information on recycling this battery, call toll-free 1-800-544-6986.

WARNINGS

Do not dispose of this unit in fire as batteries inside this product may explode or leak.
Do not expose the unit containing a battery to fire or intense heat as it may explode.
Before disposing of the battery, protect exposed terminals with heavy-duty electrical tape to prevent shorting

(shorting can result in injury or fire).

8

USING THE ALTERNATOR CHECK FEATURE

1. Turn the power switch to the off position.
2. Connect jumper cables to unit.
3. Connect to vehicle.
4. Start engine.
5. Turn vehicle accessories off. Turn the power switch to the on position.
6. A solid green LED indicates a good alternator. A solid red LED indicates a bad alternator.

Note:

This check may not be accurate for every make, manufacturer and model of vehicle. Check only 12 volt
systems.

12 VOLT DC PORTABLE POWER SUPPLY

This portable power source is also for use with all 12 volt DC accessories equipped with male accessory outlet
plugs that are rated up to 5 amps.

1.Lift up the cover of one of the unit’s 12 volt DC outlets.
2.Insert the 12 volt DC plug from the appliance into the 12 volt accessory outlet on the unit.
3.Switch on the appliance and operate as usual.
4.Periodically press the battery charge level pushbutton to check battery status.

Note:

The 12 volt DC accessory outlets on the unit are protected by a 5 amp manual resetting breaker that will
trip in the event of overload. Simply unplug the appliance to reset the breaker. To avoid tripping this
breaker, 

DO NOT USE UNIT TO POWER APPLIANCES THAT DRAW MORE THAN 5 AMPS DC.

120 VOLT AC PORTABLE POWER SUPPLY

The 120 Volt AC Power Supply is designed for maintaining today's modern lifestyle while traveling in vans, RVs,
automobiles, trucks, or vehicles that have a 12 volt DC battery power supply and a means to recharge those
batteries. The Electromate

®

400 Plus comes with:

1. AC ON/OFF Switch — to turn the AC Power Supply ON and OFF
2. 120 Volt AC Power Outlets
3. AC Power Supply “ON” Status Indicator — green LED lights when AC outlet is turned on; green LED flashes

on and off when faulted.

4. AC Power Ground Fault Circuit Interrupt (GFCI) — 3-prong outlet for 120 volt AC appliances which shut down

inverter if leakage or ground fault current is detected

5. Internal protective circuits including:

• Overload and over-temperature shutdown (activated if AC output exceeds 400 watts)
• AC short-circuit shutdown
• Low voltage shutdown
• A new cooling technology that more efficiently cools the power transistors and, combined with soft start,

dramatically increases reliability and product life

IMPORTANT: 

The unit’s AC recharging process is disabled when using this feature. To recharge the unit using the

AC recharging process, turn the AC Power Supply OFF.

AC Power Supply Controls and Indicators

Refer to the illustrations in the “Controls and Indicators” section to locate referenced controls.
Air vents keep the unit from overheating and should not be covered or blocked when the unit is in use. The
ON/OFF switch turns the AC power circuitry on and off. The ON/OFF switch can also be used to reset the AC
power after shutdown due to overvoltage, overload or over-temperature condition. The Status Indicator lights
when the AC power supply is ON. The 120 Volt AC Outlets (covered when not in use) supply power to AC appliances.

EMERGENCY AREA LIGHT

The area light is controlled by the Area Light Power Switch on the front panel of the unit. Make sure the lamp is
turned OFF when the unit is being recharged or stored. 

PORTABLE INFLATOR

Read Instructions Carefully to Avoid Possible Injury or Property Damage.

The built-in 12 volt DC inflator is the ultimate inflator for all vehicle tires, trailer tires and recreational inflatables.
Three different sized nozzles are supplied. Each nozzle clips on the end of the standard tire valve connector
attached to the free end of the inflator hose. The inflator hose with tire fitting is stored in a retaining channel
between the jumper cable channels on the rear of the unit. The ON/OFF switch is located on the front of the unit.
The inflator can operate long enough to fill up to 3 average sized tires before the battery must be recharged. The
inflator may be used by removing the air hose from the storage hatch and, if required, fitting the appropriate
nozzle to the air hose. Return the hose to the storage compartment after use.

Note:

Thermo-protection device shuts down the unit when the unit overheats and restarts once the unit has
reached a safe operating temperature.

90556511 VEC026BD.qxp:VEC026BD ManualENSP 061808  12/11/09  2:02 PM  Page 8

Summary of Contents for ELECTROMATE 400

Page 1: ... 27 Ferre Pat de Puebla S A de C V 16 de Septiembre No 6149 Col El Cerrito Puebla Puebla Tel 01 222 264 12 12 Ferre Pat de Puebla S A de C V Ejército Mexicano No 15 Col Ejido 1ro de Mayo Boca del Rio Veracruz Tel 01 229 167 89 89 Servicio de Fabrica Black Decker S A de C V Lázaro Cardenas No 18 Col Obrera Distrito Federal Tel 55 88 95 02 Representaciones Industriales Robles S A de C V Tezozomoc No...

Page 2: ... 16 14 12 12 16 14 12 Not Recommended 2 SAFETY GUIDELINES DEFINITIONS DANGER Indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate i...

Page 3: ...lamps to touch each other or another common metal conductor this could cause damage to the unit and or create a sparking explosion hazard a For negative grounded systems connect the POSITIVE RED clamp to the POSITIVE ungrounded battery post and the NEGATIVE BLACK clamp to the vehicle chassis or engine block away from the battery Do not connect the clamp to the carburetor fuel lines or sheet metal ...

Page 4: ...e event that the vehicle to be started has a Positive Grounded System positive battery terminal is connected to chassis replace steps 4a and 4b above with steps 5a and 5b then proceed to step 6 5a Connect negative black clamp to vehicle battery s negative ungrounded post 5b Connect positive red clamp to the vehicle chassis or engine block away from the battery Do not connect the clip to carburetor...

Page 5: ...ories off Turn the power switch to the on position 6 A solid green LED indicates a good alternator A solid red LED indicates a bad alternator Note This check may not be accurate for every make manufacturer and model of vehicle Check only 12 volt systems 12 VOLT DC PORTABLE POWER SUPPLY This portable power source is also for use with all 12 volt DC accessories equipped with male accessory outlet pl...

Page 6: ...inuous 400 watts 10 TROUBLESHOOTING GUIDE Jump Starter 120 Volt AC Accessory Outlet Inverter 12 Volt DC Accessory Outlets Inflator Problem Possible Cause Solution Inflator turns ON but will not inflate the tire Chuck is not properly inserted into tire valve Remove chuck and make sure it is properly inserted into tire valve Inflator will not turn ON Inflator is overheated Unit s internal battery is...

Page 7: ...os protectores o lentes de seguridad con protección lateral que cumplan con las normas de seguridad aplicables y de ser necesario un protector facial Utilice también máscaras faciales o para polvo si la operación produce polvillo Esto se aplica a todas las personas que se encuentren en el área de trabajo Utilice también un casco protección auditiva guantes calzado de seguridad y sistemas de recole...

Page 8: ...o para evitar cortocircuitos un cortocircuito puede producir lesiones o incendio Coloque esta unidad lo más lejos posible de la batería que los cables de CC permitan Nunca permita que el ácido de la batería entre en contacto con esta unidad No opere esta unidad en un área cerrada ni restrinja la ventilación de alguna forma 14 VERIFIQUE QUE NO HAYA PIEZAS DAÑADAS Antes de volver a utilizar la herra...

Page 9: ...uz solar directa el calor directo o la humedad Lea y comprenda este manual de instrucciones antes de utilizar esta unidad CONSERVE ESTAS INSTRUCCIONES ADVERTENCIA PARA REDUCIR EL RIESGO DE LESIONES Siga estas instrucciones y las publicadas por el fabricante de la batería y el fabricante de cualquier equipo que tenga la intención de utilizar con esta unidad Revise las marcas cautionary en esta unid...

Page 10: ...das las marcas los fabricantes y los modelos de vehículo Controle solamente sistemas de 12 voltios 18 Características de protección Sobrecarga automática protección incorporada contra sobrecarga en el caso de que el tomacorriente de CA genere más de 250 vatios la energía suministrada al tomacorriente de la unidad se apagará automáticamente Interruptor de corte por falla a tierra GFCI el GFCI prote...

Page 11: ...trolar el estado de la batería Nota Los enchufes accesorios de la C C de 12 voltios en la unidad son protegidos por un triturador de reajuste manual de 5 amperios que dispare en el acontecimiento de la sobrecarga Desenchufe simplemente la aplicación para reponer el triturador Para evitar de disparar este triturador NO UTILICE LA UNIDAD PARA ACCIONAR LAS APLICACIONES QUE DIBUJAN MÁS DE 5 AMPERIOS D...

Page 12: ...usa posible Solución Inflador gira pero no inflará el neumático La tirada no se inserta correctamente en la válvula del neumático Quite la tirada y cerciórese de que está insertada correctamente en la válvula del neumático Inflador no se girará Se recalienta el inflador Se agota la batería interna de la unidad Dé vuelta Al Aparato para inflar con aire APAGADO Espere aproximadamente 10 minutos él p...

Page 13: ... PRODUCT INFOMATION IDENTIFICACIÓN DEL PRODUCTO Cat No Catalogo ó Modelo Serial Number No de serie Name Nombre Last Name Apellido Address Dirección City Ciudad State Estado Postal Code Código Postal Country País Telephone No Teléfono 1 AÑO DE GARANTIA Este producto cuenta con 1 año de garantía a partir de la fecha de compra contra cualquier defecto de su funcionamiento así como cualquier falla deb...

Reviews: