background image

ENGLISH

(Original instructions)

11

Note!

 

When the unit is in Automatic mode, 

temperature levels cannot be manually controlled or 

changed.
Note!

 

When first turned on, the unit will automatically 

start on Automatic mode.

♦ 

Cooling Mode - In cooling mode, the unit will blow 

out cold air to decrease the ambient temperature. 

To select cooling mode, press the ‘Mode’ button 

repeatedly until the corresponding indicator lights 

up.

♦ 

Fan Mode - In fan mode, the unit will blow out 

natural air to cool the ambient temperature. 

To select fan mode, press the ‘Mode’ button 

repeatedly until the corresponding indicator lights 

up.

Note! When the unit is in Fan mode, temperature 

levels cannot be manually controlled or changed.

♦ 

Dehumidifying Mode - This unit is equipped with a 

dehumidifying function, which removes moisture 

from the air to purify it. 

To select dehumidifying mode, press the ‘Mode’ 

button repeatedly until the corresponding indicator 

lights up. 

Note!

 

When the dehumidifying function is selected, 

the unit will vibrate briefly as the compressor kicks 

in. This is normal and not indicative of malfunction.

♦ 

Sleep Mode - You can set the unit to operate 

overnight by pressing the Sleep button when the 

unit is in operation. 

In sleep mode, the unit will operate at low speed, 

and its temperature will increase or decrease by 

1 degree for the first two hours. The unit will then 

keep a constant temperature until turned off. 

In cooling mode, the temperature will increase; in 

fan mode, it will decrease. 

Press the Sleep button again while the unit is in 

sleep mode to turn this function off. The fan will 

resume operation and default to the latest pre-set 

mode and speed settings.

Note!

 

In sleep mode, the unit will automatically turn 

itself off after 12 hours of continuous operation.

The Timer Function

This unit is equipped with a 24-hour programmable 

timer.

Setting the Timer

♦ 

Press the Timer button on the remote control or 

on the appliance’s control panel to activate the 

timer. The number ‘0’ will appear on the unit’s LCD 

display to indicate the timer function has been 

selected.

♦ 

Once this function has been activated, 

continuously press the Timer button again to 

select your desired operation time, from 1 to 24 

hours.

Pre-Setting the Timer

♦ 

The unit’s timer can also be pre-set and used as 

a delay timer, so that the unit will begin operation 

after a set period of time.

♦ 

To pre-set a delay time, press the Timer button 

while the unit is plugged into the mains, but not in 

operation. The number ‘0’ will appear on the unit’s 

LCD display to indicate the pre-set delay timer 

function has been selected.

♦ 

Once this function has been activated, 

continuously press the Timer button again to 

select your desired delay time, from 1 to 24 hours.

Note! To cancel a pre-set delay timer, press the 

Power On/Off button to turn the unit on, then press 

the button again to turn it off if necessary. This will 

cancel any previously set delay timers.

Draining the Unit

Summary of Contents for BXAC40008GB

Page 1: ...BXAC40008GB www blackanddecker co uk ...

Page 2: ...trol Features 1 Remote Control 2 Control Panel 3 Air Outlet 4 Air Inlet 5 Cord Storage 6 Air Inlet 7 Water Stopper Drainage Point 8 Air Inlet 9 Window Hose Air Outlet 10 Air Inlet 11 Hose Adaptor 12 Window Hose 13 Window Adaptor 14 Drain Tube 15 Active Carbon Filter 16 Remote Control 1 2 3 11 12 13 5 4 6 7 8 9 10 14 15 16 ...

Page 3: ...6 Sleeping Mode Indicator 7 Mode Function Option Soft Touch Button 8 Temperature Up Soft Touch Button 9 Temperature Down Soft Touch Button 10 Indicator For Compressor Operation 11 Full Tank Indicator 12 Low Ventilation Indicator 13 Medium Ventilation Indicator 14 High Ventilation Indicator 15 Receiver For Remote Control 16 Display Window 17 Automatic Mode Indicator 18 Dehumidify Dry Mode Indicator...

Page 4: ...o reduce the risk of fire electric shock personal injury and material damage Using Your Appliance Please read the operating instructions carefully before using your air conditioner for the first time Check that the voltage of the main circuit corresponds with the rating of the appliance before operating Children shall not play with the appliance Do not let the cable hang over the edge of a table o...

Page 5: ...appliance is used near pets Do not allow the cord to become twisted After Use While cleaning DO NOT use a wet cloth or use water on any part of the unit as this may cause a short circuit or electrical shock Keep this unit clean Do not allow objects to enter the ventilation opening as this may cause electric shock or damage to the unit Switch off the unit and then remove the plug from the socket wh...

Page 6: ...erate the unit only at the voltage specified Do not use the unit near open windows as contact with rain and other natural elements could cause an electrical hazard Do not put heavy objects on the appliance Do not tip the unit on its side Never insert any other object into the unit body to avoid any hazard or unit failure Do not put the unit close to heat generating devices or near flammable and da...

Page 7: ...om with a floor area of less than 10m2 Be aware that the refrigerant may be odourless and that leaks may not be detectable by smell ALWAYS take care to comply with national gas regulations Keep ventilation openings clear of obstruction Store the appliance in a well ventilated area where the room size corresponds to the room area specified for operation Any person who is involved with working on or...

Page 8: ...Remote Control 2 Control Panel 3 Air Outlet 4 Air Inlet 5 Cord Storage 6 Air Inlet 7 Water Stopper Drainage Point 8 Air Inlet 9 Window Hose Air Outlet 10 Air Inlet 11 Hose Adaptor 12 Window Hose 13 Window Adaptor 14 Drain Tube 15 Active Carbon Filter 16 Remote Control Use About the Controls 3 speed selection 24 hour timer 3 cooling modes and dehumidifying mode Sleep mode LED display Remote Control...

Page 9: ...o place The remote control is now ready for normal use Assembling Your 3 in 1 Air Conditioner WARNING Before performing any assembly or maintenance switch the unit off and remove it from the power supply Installing the Window Hose Before using your air conditioning unit you will need to install the window hose so that hot air from the appliance is released onto an outside open air area The section...

Page 10: ...ront of the unit To position the outer louvers gently hold them by the lip and push them upwards or downwards as required Push the louvers upwards to open them or downwards to close them To position the inner louvers gently hold them by the lip and push them sideways to the left or right as required The air flow will be re directed accordingly Temperature Selection While the unit automatically adj...

Page 11: ...constant temperature until turned off In cooling mode the temperature will increase in fan mode it will decrease Press the Sleep button again while the unit is in sleep mode to turn this function off The fan will resume operation and default to the latest pre set mode and speed settings Note In sleep mode the unit will automatically turn itself off after 12 hours of continuous operation The Timer ...

Page 12: ...has been drained Note To stop the buzzing indicator sound press any button on the unit s remote control Note Always wait at least 3 minutes after switching off the unit before turning it back on This will help prolong the life of the compressor Draining Without the Tank You can also drain the unit without needing to empty the water tank To do so simply remove the drain plug and plug cap insert the...

Page 13: ...change the filter Unplug and store the power cord Place the unit back into its original box You can now safely store the unit Mains plug replacement WARNING The following section on mains plug replacement is for authorised service centre persons only If a new mains plug needs to be fitted Safely dispose of the old plug Connect the brown lead to the live terminal in the new plug Connect the blue le...

Page 14: ...t must be returned to the retailer with proof of purchase or a receipt within the 1st year of purchase For any product related issues after 12 months please contact our customer services team The product must be installed and used in accordance with the instructions contained in this instruction guide It must be used only for domestic purposes It does not cover wear and tear damage misuse or consu...

Page 15: ... 3KW Power Ampere Consumption 1350W 6 0A Air Volume 410 Compressor Rotary Refrigerant R290 200g Fan Speed 3 Timer 1 24 hours Working Temperature 18o C 32o C Window Hose 150 x 1500mm Net Weight 28 5kg Product Size W x D x H 394 x 352 x 846mm Contact Details Imported by Black Decker 210 Bath Road Slough Berkshire SL1 3YD ...

Page 16: ...United Kingdom Black Decker Tel 01753 511234 Republic Of Ireland 210 Bath Road Fax 01753 512365 www blackanddecker co uk Slough Berkshire SL1 3YD emeaservice sbdinc com 10 2019 ...

Reviews: