16 • ENGLISH
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
POSSIBLE SOLUTION
Cooling function does not work.
Loose contact between plug and
unit socket.
Plug firmly into unit socket and wall
outlet.
Unit is exposed to direct sunlight. Place the unit in a shady, cool place with
good airflow.
Ventilator or propeller is blocked.
Clean the ventilator and the propeller.
The unit is too closed to the wall
or an object.
Move the unit away from the wall or other
objects.
There is a strange noise or vibration
during operation
Unit is malfunctioning
To prevent breakdown, tur the unit off
immediately and unplug it from wall
outlet. Contact a local repair center.
There is a burning smell or the case
is deformed
Unit is overheating
To prevent breakdown, turn the unit off
innediately and unplug it from wall outlet.
Contact a local repair center.
SERVICE INFORMATION
BLACK+DECKER offers a full network of company-owned and authorized service locations. All BLACK+DECKER
Service Centers are staffed with trained personnel to provide customers with efficient and reliable power tool service.
For more information about our authorized service centers and if you need technical advice, repair, or genuine factory
replacement parts, contact the BLACK+DECKER location nearest you, or visit us at www.BlackandDecker-la.com
PROTECTING THE ENVIRONMENT
Separate collection. This product must not be
disposed of with normal household waste.
Should you find one day that your
BLACK+DECKER product needs replacement,
or if it is of no further use to you, do not dispose
of it with household waste. Make this product
available for separate collection.
Separate collection of used products and
packaging allows materials to be recycled and used
again. Re-use of recycled materials helps prevent
environmental pollution and reduces the demand
for raw materials. Local regulations may provide for
separate collection of electrical products from the
household, at municipal waste sites or by the
retailer when you purchase a new product.
SPECIFICATIONS BDC24L
Voltage
AR, B2C
220V ~ 50Hz (AC) 12V (DC)
B3
120V ~ 60Hz (AC) 12V (DC)
B2/BR
127V/220V (AC) 12V (DC)
Power consumption
DC
Cold mode: 50W
Hot mode: 45W
AC
Cold mode: 60W
Hot mode: 50W
Volume
24L
Cooling Capacity
18ºC+/-3ºC
Below ambient temperature
Heating Capacity
55ºC+/-10ºC
AC Power Cord 1.8m
DC Power Cord
2m