2
• EXTENSION CORDS.
Make sure your extension cord is in good condition. When using an
extension cord, be sure to use one heavy enough to carry the current your product will draw. An
undersized cord will cause a drop in line voltage resulting in loss of power and overheating. The
following table shows the correct size to use depending on cord length and nameplate ampere
rating. If in doubt, use the next heavier gage. The smaller the gage number, the heavier the cord.
SAFETY GUIDELINES / DEFINITIONS
DANGER:
Indicates an imminently hazardous situation which, if not avoided, will result in death
or serious injury.
WARNING:
Indicates a potentially hazardous situation which, if not avoided, could result in death or
serious injury.
CAUTION:
Indicates a potentially hazardous situation which, if not avoided, may result in minor or
moderate injury.
CAUTION:
Used without the safety alert symbol indicates potentially hazardous situation which, if
not avoided, may result in property damage.
RISK OF UNSAFE OPERATION.
When using tools or equipment, basic safety precautions should
always be followed to reduce the risk of personal injury. Improper operation, maintenance or
modification of tools or equipment could result in serious injury and property damage. There are
certain applications for which tools and equipment are designed. Black & Decker strongly
recommends that this product NOT be modified and/or used for any application other than for which
it was designed. Read and understand all warnings and operating instructions before using any tool
or equipment.
SAVE THESE INSTRUCTIONS
THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS FOR THE 2 AMP
CHARGE RATE AUTOMATIC BATTERY MAINTAINER MODEL BM2B.
WARNING: TO REDUCE THE RISK OF INJURY:
• Follow these instructions and those published by the battery manufacturer and manufacturer of any
equipment you intend to use with this unit. Review cautionary markings on these products and on engine.
IMPORTANT SAFETY INSTRUCTIONS
WARNING:
This product or its power cord contains lead, a chemical known to the State of
California to cause cancer and birth defect or other reproductive harm. Wash hands after handling.
WARNING: BURST HAZARD:
Do not use the unit for charging dry-cell batteries that are
commonly used with home appliances. These batteries may burst and cause injury to persons and
damage property. Use the unit for charging/boosting a LEAD-ACID battery only. It is not intended to
supply power to a low-voltage electrical system other than in a starter-motor application.
WARNING: SHOCK HAZARD:
• If an extension cord is used, make sure that:
a) the pins of extension cord are the same number, size and shape as those in the battery maintainer,
b) the extension cord is properly wired and in good electrical condition,
c) the wire size is large enough for the AC rating of the charger as indicated in the table on page 2.
Minimum Gage for Cord Sets
Volts
Total Length of Cord in Feet
120V
0-25
26-50
51-100
101-150
(0-7,6m)
(7,6-15,2m)
(15,2-30,4m)
(30,4-45,7m)
240V
0-50
51-100
101-200
201-300
(0-15,2m) (15,2-30,4m)
(30,4-60,9m)
(60,9-91,4m)
Ampere Rating
More
Not more
American Wire Gage
Than
Than
0 -
6
18
16
16
14
6 -
10
18
16
14
12
10 -
12
16
16
14
12
12 -
16
14
12
Not Recommended