background image

the microprocessor and will stop charging if the rate is too fast or too slow for battery
size or condition.

Battery Voltage — 

enables a check that measures the battery voltage and displays

it for 3 seconds.

Battery Recond — 

improves performance of sulfated and aged batteries.

Battery Voltage (Alternator Voltage Check) —

is a five-second check that

measures the battery voltage. This check is repeated at various electrical load levels
and the tests allow the user to determine if the alternator can keep up with the loads.
It can indicate whether alternator service may be required.

INDICATORS:

Large (.375”) 3-Character Digital Display

in the upper left of the control panel

indicates the various conditions and/or status codes:

Status Codes

are described in the following chart and on back of the charger.

CONTROL PANEL LED INDICATORS:

WET —

lights when battery type selector is on WET battery type

GEL — 

lights when battery type selector is on GEL battery type

AGM — 

lights when battery type selector is on AGM battery type 

Float Charge —

lights when automatic charge monitoring is active

Alternator Good — 

lights when load or no load checks show the alternator is

keeping up with the electrical load

BUTTON (BELOW THE DIGITAL DISPLAY):

Equalizing — 

a recessed button used to start the equalization process.

AC POWER INDICATOR - 

When connected to an AC outlet, digital display shows circulating pattern to

indicate power is on. Disconnect charger after use.

FAULT CODES

OPERATION CODES

F01

F02

F03

F04

F05
F06
F07

000
FUL

INTERNAL SHORTED CELL BATTERY - 

Cannot be charged, bad battery. Replace battery.

 

EXCESSIVE LOAD ON BATTERY WHILE CHARGING - 

Check load.

BAD BATTERY CONNECTION - 

Check battery connection.

BATTERY VOLTAGE TOO LOW TO ACCEPT CHARGE - 

Bad battery. Replace battery.

BATTERY RECONDITIONING - 

(The letters 

DES

 will display for the first 3 seconds.)

INTERNAL OPEN CELL - 

Bad battery. Battery needs to be replaced.

SULFATED CONDITION - 

Battery needs to be reconditioned or replaced. See manual.

OVERHEATED CONDITION - 

Disconnect charger and allow to cool for 30 min., check for ample ventilation.

REVERSE POLARITY

BAD ALTERNATOR

ALTERNATOR VOLTAGE CHECK
CHARGER STANDBY
BATTERY FULLY CHARGED

OVERTIME CONDITION - 

Battery will not accept a charge after 18 hours of continuous charging.  Battery has internal

damage and needs to be replaced or 

BATTERY CHARGE RATE IS SET TOO LOW -

 Set charger to higher charge rate.

See manual.

internal chemical energy transfer. At the end of Stage 2, the charger will signal "beep"
and move into Stage 3 charge mode.

Stage Three —

Top-Off Charge — voltage is automatically maintained and

reduced to a predetermined level while current is adjusted for a safe, effective battery
charge. At the conclusion of Stage 3, the unit will BEEP signaling the completion of
the charging cycle.
The Automatic Float Charge feature is ideal for maintaining a battery. It automatically
tops off battery as needed, to keep battery fully charged all the time.

FEATURES

• This unit has three charge rate settings, accessed by the 2/10/15 AMP button:

a) 2 amps: smaller batteries, as in lawn mowers, snowmobiles, motorcycles, etc.
b) 10 amps: mid-sized batteries, as in small cars
c) 15 amps: automobiles and light trucks

• Automatic Temperature Compensation
• Battery type selection
• Digital diagnostics
• Alternator voltage and battery voltage check
• Digital display
• 3

1

2

-minute engine start

• 3-stage, high-frequency switch mode automatic rapid charging
• Spark resistant reverse polarity and short circuit protection for user
• Built-in battery reconditioning (desulfate)
• Lightweight, high efficiency design
• Internal short circuit protection
• Cables and clamps self stored
• Reverse polarity indicator
• Microprocessor control (Digital Smart Control)/High frequency power
• Compensates for low AC from extension cord use
• Equalization function
• Battery recondition function

Controls and Indicators

FUNCTION BUTTONS (FROM RIGHT TO LEFT):

Battery Type — 

allows the user to select wet battery, gel battery or AGM battery.

2/10/15 Charge Rate Selector — 

allows the user to select the charger rate

based on battery size. This selection and actual battery charge rate are monitored by

CONTROL PANEL

DIGITAL READOUT

CIRCULATING PATTERN

Summary of Contents for 2 Amp 12 Volt

Page 1: ...M M M MA A A AT T T TIII IO O O ON N N N S S S SA A A AV V V VE E E E T T T TH H H HE E E ES S S SE E E E III IN N N NS S S ST T T TR R R RU U U UC C C CT T T TII I IO O O ON N N NS S S S K OF INJURY USER MUST READ AND UNDERSTAND L MANUAL THIS MANUAL CONTAINS IMPORTANT ARDING THE OPERATION AND WARRANTY OF THIS AIN FOR FUTURE REFERENCE ...

Page 2: ...AD ACID BATTERY IS DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY 2 To reduce risk of battery explosion follow these instructions and those published by the battery manufacturer and manufacturer of any equipment you intend to use...

Page 3: ... battery terminal 8 Do not charge the battery while the engine is operating 9 See operating instructions for length of charge information Follow these steps when the battery has been removed from a vehicle A spark near the battery may cause an explosion To reduce risk of a spark near the battery 1 Check polarity of battery posts the Positive posts marked POS P usually has a larger diameter than th...

Page 4: ...CONDITION Disconnect charger and allow to cool for 30 min check for ample ventilation REVERSE POLARITY BAD ALTERNATOR ALTERNATOR VOLTAGE CHECK CHARGER STANDBY BATTERY FULLY CHARGED OVERTIME CONDITION Battery will not accept a charge after 18 hours of continuous charging Battery has internal damage and needs to be replaced or BATTERY CHARGE RATE IS SET TOO LOW Set charger to higher charge rate See ...

Page 5: ...efully followed by anyone installing or using the charger Follow the steps outlined in Important Safety Instructions at the front of this manual Charge Rate Selection After charger clamps are correctly connected plug in the charger to a 120 volt AC outlet The charger will show a circulating pattern on the Digital Display indicating power has been applied Select the proper charge current rate based...

Page 6: ...ery section on page 4 of this manual 8 Push the Battery Type Selector Switch until WET is displayed This mode will only work if a WET battery is selected 9 Choose the correct charge rate and start charging You can check the battery voltage by pushing the Battery Voltage button This will trigger the Battery Voltage indicator button 10 Push the Equalize button at any time and the battery will automa...

Page 7: ...e charger may be blocked Follow the steps outlined in Important Safety Instructions at the front of this manual to disconnect AC cord and clamps allow the unit to cool for 30 minutes and reconnect Make sure there is ample ventilation before resuming operation F06 Reverse Polarity The connections to the battery s POSITIVE and NEGATIVE terminals are incorrect Follow the steps outlined in Important S...

Reviews: