AL200 swinghandle manual
7
3.5
Connection
To connect the handle to external access control systems, use the AW200 or AW205 cable (see chapter 5 Accessories). The cable can be extended
to a maximum length of 100m using UTP Cat5e cable.
Connectors
Socket type 53047-0810
1
w/brown
GND
Power supply input: GND
2
brown
+12V
Power supply input: +12V DC
3
w/green
STATUS
Open collector output for signalling the position of the handle, I
C
=50mA, U
CE
=25V.
Handle open -> NPN transistor open (active)
Handle closed -> NPN transistor closed (inactive)
4
green
CTRL
Input for controlling the swinghandle from an external system.
Opening the handle -> CTRL shorted to GND or +12V
Closing the handle -> CTRL not connected
5
blue
SENSOR
Door sensor input - for the future use. Do not connect.
6
w/blue
GND
GND - for the door sensor - for the future use. Do not connect.
7
orange
CANL
CAN bus interface (CANL) - for the future use. Do not connect.
8
w/orange
CANH
CAN bus interface (CANH) - for the future use. Do not connect.
Socket type 53047-0410 for the future use. Do not connect.
1 For the future use. Do not connect.
2 For the future use. Do not connect.
3 For the future use. Do not connect.
4 For the future use. Do not connect.
4
Operation
4.1
Electrical opening
Electric opening is made by shorting the CTRL input to the GND or +12V potential. If the CTRL input is not connected anywhere, then the
swinghandle remains closed.
CTRL input state
Swinghandle lock status
CTRL input not
connected
Lock is closed
CTRL input not
connected to
GND or +12V
Lock is open
PIN 1
PIN 8
or