background image

Rotisserie Ventless Hood  

Maintenance 

 

 

12 

Maintenance 

 

 

Electrocution could occur if this unit is hosed down with water. This unit is NOT 
designed for hose wash-down cleaning! Refer to scheduled maintenance below 
for proper hood cleaning. 
 

 

Electrocution could occur if power is not removed from this unit before servicing. 
Remove power at disconnect or circuit breaker 

BEFORE

 servicing hood. 

Scheduled Maintenance  

Use the following table to help manage scheduled maintenance activities. 
 

FREQUENCY PERFORMED 

BY 

PART 

ACTIVITY 

Daily 

User 

Entire Hood 

Wipe unit down with a soft rag and mild 
cleaning agent. 

 User  Condensation 

trough 

Check condensation trough. Empty if 
necessary. 

 

User 

Grease Baffle 

Clean grease baffle. If necessary, refer 
to the procedure in this manual for 
cleaning the baffle. 

Weekly 

User Charcoal/Odor 

Filter 

Inspect 

charcoal/odor filter. In low to 

medium volume applications, the filter 
may need replacement prior to the 
indicating light turning on. This 
condition will be evident by a strong 
odor coming from the face of the filter. 
If necessary, refer to the procedure in 
this manual for replacing the filter. 

Monthly 

User 

Door and Filter 
Interlock 

Check door and filter interlock 
operation. The unit should not operate 
with the front door open or either the 
grease baffle or charcoal/odor filter 
removed. Clean area between grease 
baffle and charcoal/odor filter.  

 

 

Injury from rotating fan blades could occur if power is not removed from this unit 
before cleaning the blower section. Remove power at disconnect or circuit breaker 

BEFORE

 cleaning the blower section. 

 

3 Months 

User 

Blower Section 

Clean the blower section. 

 

Summary of Contents for Rotisserie Ventless Hood VGH-Series

Page 1: ...Rotisserie Ventless Hood MODEL VGH Series Installation Operation Manual Serial Numbers 195937 and higher ...

Page 2: ...ville South Carolina or F O B authorized BKI Distributor The Company and or its authorized representatives will assume the normal replacement labor expense for the defective part for the period of the warranty as stated above excluding travel and or other expenses incidental to the replacement of the defective part where replacement work is performed during standard business hours and not subject ...

Page 3: ...ation 6 Unpacking and Handling 6 Inspection for Shipping Damage 6 Location and Clearance 6 Detailed Installation Instructions 6 Wiring 7 Baffle Grease Odor Filter 8 Operation 9 Principles of Operation 9 Controls and Indicators 9 Preparation 10 Start Up 10 Shut Down 10 When to Replace the Filter 10 Cleaning 11 Maintenance 12 Scheduled Maintenance 12 Cleaning the Grease Baffle 13 Replacing the Charc...

Page 4: ...nce will result in long lasting dependability to insure the highest profitable return on your investment PLEASE READ THIS ENTIRE MANUAL BEFORE OPERATING THE UNIT If you have any questions please contact your BKI Distributor If they do not answer your questions contact the BKI Technical Service Department toll free 1 800 927 6887 Outside the U S call 1 864 963 3471 Safety Precautions Always follow ...

Page 5: ...nce remains in the proper position on top of the rotisserie hood during normal operation DO NOT TIP PULL OR PUSH APPLIANCE WITHOUT PROVIDING ADEQUATE PRECAUTION Hood failure could result if the hood is operated without the grease baffle and particle odor filter installed This is a special filter designed for this application only other filters will not work properly Use only a BKI particle odor fi...

Page 6: ...1 911 Prepare for Emergencies Be prepared for fires injuries or other emergencies Keep a first aid kit and a fire extinguisher near the equipment You must use a 40 pound Type BC fire extinguisher and keep it within 25 feet of your equipment Keep emergency numbers for doctors ambulance services hospitals and the fire departments near your telephone Know your responsibility as an Employer Make certa...

Page 7: ...nsure compliance with applicable codes In the event of an appliance fire serious injury property damage or death could occur if the appliance is powered from a source other than the rotisserie for which it is designed for The hood used on top of the appliance MUST receive its input power from the appliance This hood has not been installed with Fire Extinguishing System This filter hood is an Inter...

Page 8: ... the store location VGG s already in service may be fitted with the hood at a store location as a retro fit installation Disconnect VGG rotisserie from the electrical supply before attempting installation VGH 8 Hood for use only with BKI Models VGG 8 or VGG 16 rotisseries VGH 5 Hood for use only with BKI Model VGG 5 rotisserie Detailed Installation Instructions 1 Remove side panel on the control s...

Page 9: ...r if the appliance is powered from a source other than the oven The hood MUST receive its input power from the rotisserie for which it is mounted on 1 Feed power wires and interlock wires through access hole into VGG 2 The power wires 14 15 and ground are wired as follows 3 phase 3 wire 3 phase 4 wire 3 For interlock remove 5 wire from VGG Power Switch Crimp male connector provided with VGH onto 5...

Page 10: ...e plastic bag 2 Open the hood and filters doors on the front of the unit by pulling on the handles 3 Observing the FRONT marking on the grease filter and facing the control side of the hood away from the blower slide the filter into the unit as shown Repeat for the Charcoal filter with the ARROW mark showing air flow direction pointing towards the blower 4 Close the filters and hood doors ...

Page 11: ...ors from the air The filtered air then passes through the blower and is returned to the room The VGG oven may now be energized and operated normally Refer to the Rotisserie manual on operations of the VGG If a hood door is opened the Door Latch pilot light illuminates and a relay opens the control circuit in the VGG causing the VGG to immediately power off If either filter is removed the Check Fil...

Page 12: ...utton to position I Shut Down Power to the appliance is turned off when the hood is turned off For proper operation always turn off appliance and allow time for it to cool before turning off the filter hood This will insure proper capture of grease vapors To stop the Filter Hood press the power On Off rocker switch button to 0 When to Replace the Filter The vacuum switch is designed to monitor the...

Page 13: ... down with dirty filters In low to medium volume applications the charcoal filter may need replacement prior to the REPLACE FILTERS light illuminating If you smell a strong odor coming from the face of the filter and the REPLACE FILTERS light is not illuminated the filter needs to be replaced If necessary refer to the procedure in this manual for replacing the filters see page 13 Cleaning Refer to...

Page 14: ...ecessary refer to the procedure in this manual for cleaning the baffle Weekly User Charcoal Odor Filter Inspect charcoal odor filter In low to medium volume applications the filter may need replacement prior to the indicating light turning on This condition will be evident by a strong odor coming from the face of the filter If necessary refer to the procedure in this manual for replacing the filte...

Page 15: ...lling out on the handles 3 Slide the used filter out of the unit 4 Remove the replacement filter from the plastic bag 5 Observing the AIR FLOW DIRECTION mark on the filter slide the filter into the unit When installing a new filter slight resistance should be observed as the filter is being slid into place This resistance is generated by flap metal plates located on the top of the filter compartme...

Page 16: ...P O Box 80400 Simpsonville S C 29680 0400 USA http www bkideas com Made and printed in the U S A LI0296 0808 ...

Reviews: