57
following screen should be displayed.
While in parallel connection mode, the output voltage of
each power supply should be set to equal value. If the
voltage value of each unit is not the same, the higher
output voltage will feed back to the lower voltage unit
and damage its internal components.
DO NOT connect multiple power supplies in series as it
will cause damage or malfunction.
When connecting in parallel mode, only the MASTER
unit can be controlled by a computer for remote
communication. There is also a decrease in speed and
performance with each additional SLAVE units
connected in parallel and linked together. The voltage
and current scan speed, which affects synchronization
between the supplies, between the slave units and the
master unit will increase based on the following
formula:
200 + 50 * (N – 1) (in milliseconds)