erase
•
read
If device operation is finished with error(s) it is not successful operation.
When new device type is selected, all statistics values are set to zero and
Count down
is set
to
Disabled
.
Reset
button in
Statistics
panel reset statistics values.
Reload Count down
button in
Statistics
panel reloads initial value to
Count down
.
Device / Device options / Associated file
This command is used for setting associated file with current device. This is a file, which can
be automatic loaded to buffer after device is selected from default devices select list or by
start control program.
You can edit the associated file name in file name box, put a full pathname. The control
program checks the present of this file on the disk. Also is possible enabling or disabling
automatic load of this file.
You can save both settings i.e. associated file and enabling of automatic load of this file to
disk by command
File / Exit and save
.
Device / Device options / Special options
The special terms used here are exactly the terms used by manufacturer of respective chip.
Please read the documentation to the chip you want to program for explanation of all used
terms.
If the name of this menu item is starting by "View/Edit ...", then the Read device command will
read the content of the chip configuration and it can be viewed and edited by this menu
command.
Device / Blank check
This command allows to blank check of all devices or its part if possible. The control program
reports a result of this action by a write of a warning message to INFO window.
The menu command
Device / Device options / Operation options
allows to set another
working area as the standard.
Device / Read
This command allows to read all device or its part into the buffer. The read procedure can
also read the contend of the chip configuration (if it exists and is readable). The special
device configuration areas can be viewed or edited in dialogs available by menu
View / Edit
buffer
and menu
Device / Device options / Special options
(Alt+S).
The control program reports a finish of Read action by writing a message to INFO window.
The menu command
Device / Device options / Operation options
allows to set another
working area as the standard. Setting an option Verify data after reading in this menu
command means a higher reliability for device reading.
98
Summary of Contents for 844USB
Page 7: ...Introduction 7 ...
Page 12: ...Quick Start 12 ...
Page 15: ...Detailed description 15 ...
Page 16: ...859 16 ...
Page 28: ...866B 28 ...
Page 41: ...844USB 41 ...
Page 50: ...848A 50 ...
Page 56: ...Setup 56 ...
Page 67: ...Pg4uw 67 ...
Page 117: ...Pg4uwMC 117 ...
Page 127: ...Common notes 127 ...
Page 134: ...Troubleshooting and warranty 134 ...