Technical description
Vertical Deflection
Channels:
Analog:
2
Digital:
2
Operating Modes:
Analog:
CH 1 or CH 2 separate, DUAL (CH 1 and
CH 2 alternate or chopped), Addition
Digital:
Analog Signal Channels: CH 1 or CH 2
separate, DUAL (CH 1 and CH 2)
Y in XY-Mode:
CH 1
Invert:
CH 1, CH 2
Bandwidth (-3 dB):
2 x 0 - 150 MHz
Rise time:
‹ 2.3 ns
Overshoot:
max. 1 %
Deflection Coefficient(CH 1, 2):
14 calibrated steps
1 mV – 2 mV/cm (10 MHz) ± 5 % (0 - 10 MHz (-3 dB))
5 mV – 20 V/cm
± 3 % (1-2-5 sequence)
variable (uncalibrated):
› 2.5 :1 to › 50 V/cm
Inputs CH 1, 2:
Impedance:
1 MΩ // 15 pF
Coupling:
DC, AC, GND (ground)
Max. Input Voltage:
400 V (DC + peak AC)
Y Delay Line (analog):
70 ns
Measuring Circuits:
Measuring Category
Digital mode only:
Select. switching thresholds:
TTL, CMOS, ECL
User definable thresholds:
3
within the range
-2 V to +3 V
Analog mode only:
Function (selectable):
Extern Trigger, Z (unblank)
Coupling:
AC, DC
Max. input voltage:
100 V DC + peak AC
Triggering
Analog and Digital Mode
Automatic (Peak to Peak):
Min. signal height:
5 mm
Frequency range:
10 Hz - 250 MHz
Level control range:
from Peak- to Peak+
Normal (without peak):
Min. signal height:
5 mm
Frequency range:
0 - 250 MHz
Level control range:
–10 cm to +10 cm
Operating modes:
Slope/Video/Logic
Slope:
positive, negative, both
Sources:
CH 1, CH 2, alt.1/2 (
≥
8 mm), Line, Ext.
Coupling:
AC:
(10 Hz-250 MHz)
DC:
(0 -250 MHz)
HF:
(30 kHz–250 MHz)
LF:
(0 -5 kHz)
Noise Rej. switchable
Video:
pos./neg. Sync. Impulse
Standards:
525 Line/60 Hz Systems
625 Line/50 Hz Systems
Field:
even/odd/both
Line:
all/line number selectable
Source:
CH 1, CH 2, Ext.
Indicator for trigger action:
LED
External Trigger via:
(0.3 V
pp
, 150 MHz)
Coupling:
AC, DC
Max. input voltage:
100 V DC +peak AC
Digital mode:
Logic:
AND/OR, TRUE/FALSE
Source:
CH1 or 2
State:
X, H, L
Pre/Post Trigger:
-100 % to +400% related to complete memory
Analog mode
2nd Trigger
Min. signal height:
5 mm
Frequency range:
0 - 250 MHz
Coupling:
DC
Level control range:
–10 cm to +10 cm
Horizontal Deflection
Analog mode
Operating modes:
A, ALT (alternating A/B), B
Time base A (Sequence):
0.5 s/cm - 50 ns/cm (1-2-5 sequence)
Time base B (Sequence):
20 ms/cm – 50 ns/cm (1-2-5 sequence)
Accuracy A and B:
± 3 %
X-Mag. x10:
to 5 ns/cm
Accuracy X x10:
± 5 %
Variable time base A/B:
cont. 1:2.5
Hold Off time:
var. 1:10 LED-Indication
Bandwidth X-Amplifier:
0 - 3 MHz (-3 dB)
X-Y phase shift ‹ 3°:
‹ 220 kHz
Digital mode
Time base range (sequence)
Refresh Mode:
20 ms/cm - 5 ns/cm (1-2-5 sequence)
with Peak Detect:
20 ms/cm – 50 ns/cm (1-2-5 sequence)
Roll Mode:
50 s/cm – 50 ms/cm (1-2-5 sequence)
Accuracy time base
Time base:
50 ppm
Display:
± 1 %
MEMORY ZOOM:
max. 40,000:1
Bandwidth X-Amplifier:
0 - 150 MHz (-3 dB)
X-Y phase shift ‹ 3°:
‹ 100 MHz
Digital Storage
Acquisition (real time):
Analog channels: 2 x 500 MSa/s,
1 GSa/s interleaved
Acquisition (random sampling):
Analog channels:10 GSa/s
Bandwidth:
2 x 0 - 150 MHz (random)
Memory:
1 M-Samples per channel
Operating modes:
Refresh, Average, Envelope/
Roll: Free Run/Triggered, Peak-Detect
Resolution (vertical):
8 Bit (25 Pts/cm)
Resolution (horizontal):
Yt:
11 Bit (200 Pts/cm)
XY:
8 Bit (25 Pts /cm)
Interpolation:
Sinx/x, Dot Join (linear), Pulse
Delay:
1 Million * 1/Sampling Rate to
4 Million * 1/Sampling Rate
Display refresh rate:
max.170/s at 1 MPts
Display:
Yt, XY (acquired points only), Interpolation,
Dot Join
Reference Memories:
9 with 2 kPts each (for recorded signals)
Display:
2 signals of 9 (free selectable)
Operation/Measuring/Interfaces
Operation:
Menu (multilingual), Autoset, help
functions (multilingual)
Save/Recall (instrument parameter settings):
9
Signal display:
max. 4 signals or 4 traces
analog:
CH 1, 2 (Time Base A) in combination with
CH 1, 2 (Time Base B)
digital:
CH 1, 2 ZOOM or Reference
or Mathematics)
Frequency counter:
6 digit resolution:
›1 MHz – 250 MHz
5 digit resolution:
0.5 Hz – 1 MHz
Accuracy:
50 ppm
Auto Measurements:
Analog mode:
Frequency, Period, Vdc, Vpp, Vp+, Vp-
add. in digital mode:
V
rms
/V
avg
Cursor Measurements:
Analog mode:
∆
V,
∆
t, 1/
∆
t (f), V to GND, ratio X, ratio Y
add. in digital mode:
Pulse count, Vt to Trigger Peak to Peak,
Peak+, Peak-
Resolution Readout/Cursor:
1000 x 2000 Pts, Signals: 250 x 2000
Interfaces (plug-in):
RS-232
Mathematic functions
Number of Formula Sets:
5 with 5 formulas each
Sources:
CH 1, CH 2, Math 1-Math 5
Targets:
5 math. memories, Math 1-5
Functions:
ADD, SUB, 1/X, ABS, MUL, DIV, SQ, POS,
NEG, INV
Display:
max. 2 math. memories (Math 1-5)
Display
CRT:
D14-375GH
Display area (with graticule):
8 cm x 10 cm
Acceleration voltage:
approx. 14 kV
General Information
Component tester
Test voltage:
approx. 7 V
rms
(open circuit), approx. 50 Hz
Test current:
max. 7 mA
rms
(short circuit)
Reference Potential :
Ground (safety earth)
Probe ADJ Output:
1 kHz/1 MHz square wave signal 0.2 V
pp
(tr ‹ 4 ns)
Trace rotation:
electronic
Line voltage:
105 – 253 V, 50/60 Hz ± 10 %, CAT II
Power consumption:
47 Watt at 230 V, 50 Hz
Protective system:
Safety class I (EN61010-1)
Weight:
5.6 kg
Cabinet (W x H x D):
285 x 125 x 380 mm
Ambient temperature:
0° C ...+40° C
Accessories supplied:
Line cord, Operating manual, 4 Probes 10:1 with attenuation ID, Windows Software for control and data transfer
150 MHz (1GS/s) Analog Digital Oscilloscope 5105B
Specifications and information is subject to change with out notice. For the most current product information please visit www.bkprecision.com