26
Subject to change without notice
EXIT MENU
POSITION 1
POSITION 2
HORIZONTAL
CH 3
CH 4
MATH
SAVE/
RECALL
AUTOSET
RUN
ACQUIRE
SETTINGS
HELP
CH 1/2
VOLTS / DIV
SCALE
·
VAR
VOLTS / DIV
SCALE
·
VAR
TIME / DIV
SCALE
·
VAR
AUTO/
CURSOR
MEASURE
20 V
1 mV
20 V
1 mV
X-POS
MODE
FILTER
SOURCE
TRIG
’
d
NORM
HOLD OFF
INPUTS
1M
Ω
II15pF
max
400 Vp
X-INP
LOGIC
INPUTS
1M
Ω
II15pF
max
100 Vp
TRIG
EXT
INTENS
!
TRIGGER
LEVEL A/B
ANALOG
DIGITAL
MIXED SIGNAL
OSCILLOSCOPE
1 GSa
·
1 MB
150 MHz
CH 1
50s
5ns
Z-INP
CURSOR
DIGITAL
ANALOG
DELAY
CH 3/4
MA/REF
ZOOM
VERT/XY
CH 2
CH 3/4
HOR
MAG
FOCUS
TRACE
MENU
REMOTE OFF
CAT I
!
CAT I
!
STOP
REM
VAR
VAR
VAR
x10
POWER
POWER
20
1
2
3
4
5
6
7
8
9
10
11
12
13
16
19
36
26
38
29
37
35
34
31
32
33
18
15
27
23
25
21
28
24
22
30
17
14
C o n t r o l s a n d R e a d o u t
Controls and Readout
POWER
Mains switch with symbols
I
= ON and = OFF.
After turning the scope on and after the warm-up time of the
crt heater has elapsed the
and the version number are displayed. If prior to switching off
the function ”Quick Start“ was selected (SETTINGS
>
Misc)
the above will not be displayed. Then the scope will assume
the settings which existed before switching off.
INTENS knob
This knob controls various functions:
2.1
Trace intensity if the FOCUS/TRACE/MENU
pushbutton
does not light the knob symbol
. Turn left for decreasing
and right for increasing.
2.2
If the knob symbol XXX of the pushbutton
is illuminated
the control will act for those functions displayed in the menu,
which were activated.
FOCUS TRACE MENU
If the knob symbol
will light after pressing this pushbutton
the Int.Knob menu will be shown.
Depending on the operating mode the menu contains:
A-Int.:
Intensity of the signal as displayed by time base A
B-Int.:
Intensity of the signal as displayed by time base B
(analog mode only)
Zoom Int.
Intensity of the signal as displayed by ZOOM
(digital mode only)
RO-Int.:
Readout intensity
Focus:
Focus for signal and readout
Readout
On Off:
Turning the readout off will eliminate interference
of the readout with the signal(s). The knob symbol
will blink as long as the readout is off. Only menus
and help texts will be shown.
Trace rotation:
Trace rotation (see TR)
After turn-on the readout will always be on.
EXIT MENU/REMOTE OFF (REM)
This pushbutton has two functions:
4.1
If a menu is displayed pressing this pushbutton will turn it
off. On condition a submenu is displayed, pressing this
pushbutton switches back to the menu.
AUXILIARY INPUT
TRIGGER
EXTERN
Z-INPUT
1M
Ω
II
15pF
max
100 Vp