Safety Summary

The following safety precautions apply to both operating and maintenance personnel and must be
observed during all phases of operation, service, and repair of this instrument. Before applying power,
follow the installation instructions and become familiar with the operating instructions for this
instrument.

Failure to comply with these precautions or with specific warnings elsewhere in this manual violates
safety standards of design, manufacture, and intended use of the instrument. B&K assumes no liability for
a customer’ s failure to comply with these requirements. This is a Safety Class I instrument.

GROUND THE INSTRUMENT

To minimize shock hazard, the instrument chassis and cabinet must be connected to an electrical ground.
This instrument is grounded through the ground conductor of the supplied, three-conductor ac power
cable. The power cable must be plugged into an approved three-conductor electrical outlet. Do not alter
the ground connection. Without the protective ground connection, all accessible conductive parts
(including control knobs) can render an electric shock. The power jack and mating plug of the power
cable meet IEC safety standards.

DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE

Do not operate the instrument in the presence of flammable gases or fumes. Operation of any electrical
instrument in such an environment constitutes a definite safety hazard.

KEEP AWAY FROM LIVE CIRCUITS

Instrument covers must not be removed by operating personnel. Component replacement and internal
adjustments must be made by qualified maintenance personnel. Disconnect the power cord before
removing the instrument covers and replacing components. Under certain conditions, even with the
power cable removed, dangerous voltages may exist. To avoid injuries, always disconnect power and
discharge circuits before touching them.

DO NOT SERVICE OR ADJUST ALONE

Do not attempt any internal service or adjustment unless another person, capable of rendering first aid and
resuscitation, is present.

Do not install substitute parts or perform any unauthorized modifications to this instrument. Return the
instrument to vendor for service and repair to ensure that safety features are maintained.

WARNINGS AND CAUTIONS

WARNING

and

CAUTION

statements, such as the following examples, denote a hazard and appear

throughout this manual. Follow all instructions contained in these statements.

A

WARNING

statement calls attention to an operating procedure, practice, or condition, which, if not

followed correctly, could result in injury or death to personnel.

A

CAUTION

statement calls attention to an operating procedure, practice, or condition, which, if not

followed correctly, could result in damage to or destruction of part or all of the product.

Summary of Contents for 4013DDS

Page 1: ...1 Model 4013DDS 12 MHz Sweep Function Generator...

Page 2: ...r consequential damages So the above limitation or exclusion may not apply to you This w arranty gives you specific rights and you may have other rights w hich vary from state to state Service Informa...

Page 3: ...1 2 DESCRIPTION 5 1 3 SPECIFICATIONS 5 1 4 TECHNICAL SUPPORT 6 Section 2 Installation 2 1 INTRODUCTION 7 2 3 INSTRUMENT MOUNTING 7 2 4 POWER REQUIREMENTS 7 2 5 GROUNDING REQUIREMENTS 7 2 7 ACCEPTANCE...

Page 4: ...presence offlammable gases or fumes Operation ofany electrical instrument in such an environment constitutes a definite safety hazard KEEP AWAY FROM LIVE CIRCUITS Instrument covers must not be remove...

Page 5: ...odel 4013DDS Function Generator 1 2 DESCRIPTION The Model 4013DDS is a versatile high performance function generator Implemented using advance digital technologies based on DDS topology the units gene...

Page 6: ...ariable up to 10V 5V into 50 Absolute peak amplitude plus of f set limited to 10V 5V into 50 OUTPUT IMPEDANCE 50 OUTPUT PROTECTION The generator main output is non destructiv ely protected against sho...

Page 7: ...eck for the Model 4013DDS Function Generator 2 2 MECHANICAL INSPECTION This instrument was carefully inspected before shipment Upon receipt inspect the instrument for damage that might have occurred i...

Page 8: ...cable must be plugged into an approved three conductor electrical outlet WARNING Do not alter the ground connection Without the protective ground connection all accessible conductive parts including c...

Page 9: ...set up of paragraph 2 7 1 select Square waveform and push the DUTY CYCLE ON control Rotate the DUTY CYCLE knob from full CCW to CW and observe a waveform symmetry change Section 3 Operating Instructi...

Page 10: ...specifications An RG 58 coaxial cable equipped with BNC connectors and terminated with a 50 feed through termination is recommended Using the 50 terminator minimizes signal reflection and power losses...

Page 11: ...ly press the 20 dB attenuator button and rotate the AMPLITUDE control to verify that the waveform amplitude changes Return these controls to the preset condition 5 Push the OFFSET ON button and rotate...

Page 12: ...not exceed 10V into open circuit and 5V into 50 The maximum current which can be taken from the output in DC or AC modes is limited to 100 mA maximum 3 5 5 Sweep Operation The internal sweep mode allo...

Page 13: ...13...

Reviews: