14
7.
USING THE PRESET FEATURES
PRESET PROGRAM SYMBOLS
Program
Unit is ready for inputting of a Preset Program Number (19).
Recall
Unit is ready for recalling a Preset Program Number.
The unit can store nine preset voltage and current settings.
Once programmed, these settings will be retained even when the unit is switched off.
Preset Programming
1.
Press
PROG
key
The display will show
Program_
Key in Program Number (1-9) at the keypad
2.
The display will show :-
a)
The newly keyed in Program Number.
b)
The old settings of voltage and current with
V-set
ready for voltage to be reset.
c)
Set the required voltage level than press
ENTER
to confirm.
d)
The display will show
I-set
ready for current level to be reset.
e)
Set required current level then press
ENTER
to confirm.
f)
The program will automatically advance to the next Preset (as shown in the display
Program_
section).
g)
If you want to change the voltage and current setting of next Preset repeat procedure B to E, otherwise just press
ENTER
to
go to the next Preset.
Whenever you want to determine Preset Programming you can press the
CLEAR
key to return to normal operation mode.