Table 1.
5.3_
The Enabler will activate/deactivate the load
when the programmed button in the controller
is pressed.
The bed movements will be carried out depending on
the selected operating mode:
Dead man’s mode (codes from 129 to 132 or
from 135 to 138):
The bed will move while the remote’s button is
pressed.
Pulse mode (codes from 141 to 144 or from 147
to 150)
Once the remote’s button is pressed, the bed will
move during 2 seconds and then will stop. To activate
the movement, the remote’s button must be pressed
again.
To change the code in the selector, disconnect the
enabler from the power supply, wait five seconds and
reconnect the circuit.
Maintenance
The device can be cleaned using a damp soft
cloth. Always carry this operation out with the
enabler disconnected.
In the event of a fault in the enabler, do not
handle it and contact your distributor.
Disposal
Waste electrical products should not be
disposed of with household waste!
Dispose of the waste product via a
collection point for electronic scrap or via
your specialist dealer.
Put the packaging material into the
recycling bins for cardboard, paper and
plastics.
Warranty
Within the statutory warranty period we undertake
to rectify free of charge by repair or replacement
any product defects arising from material or
production faults.
Any unauthorized tampering with, or modifications
to the product will annul this warranty.
Conformity
This product complies with the essential
requirements of the Directive 2004/108/EC.
The Declaration of Conformity can be downloaded
from the product’s webpage at
Customer Service
If, despite of correct handling, faults or
malfunctions occur or if the product was
damaged, please contact us at the address
below:
BJ Adaptaciones
C/ Mare de Déu del Coll, 70, Bajos
08023 Barcelona
Spain
Phone:+34 93 285 04 37
Fax: + 34 93 553 56 34
e-Mail:
Selector position
0
1
RF
C
o
de
Dea
d
m
a
n
mode
Raise head
129
135
Lower head
130
136
Raise foot
131
137
Lower foot
132
138
Pul
se
m
ode
Raise head
141
147
Lower head
142
148
Raise foot
143
149
Lower foot
144
150
Waste electrical productos
Do not make any unauthorized alterations or
modifications to the unit.
The relay contact is only suitable for
low voltage
power supply
(12-24 V dc/ac)
Observe the manufacturer’s instructions for the device
to be operated.
5. General information
Dealer information: