<Function 381> GS ( k pL pH cn fn m (fn=81)
Code:
ASCII
GS
(
k
pL
pH
cn
fn
m
Hex
1D
28
6B
03
00
33
51
m
Decimal
29
40
107
3
0
51
81
m
Range:
pL + pH x 256) = 3 (pL=3, pH=0)
cn=51
fn=81
m=48
Default:
None
Description:
This command encodes and prints
2-dimensional GS1 DataBar
symbol data saved in the storage area.
Remarks:
■
In standard mode, this command is available only when printer is at the beginning of a line or the printer buffer is
empty.
■
A symbol exceeding the printing area in size can not be printed.
■
Printing operation is not processed under the following conditions:
•
There is no data. (Function 380 cannot be executed)
■
In standard mode, the paper feed amount set by the paper feed setting command does not affect printing of the
symbol. The printing position returns to the left side of the printable area after printing the symbol.
■
In page mode, the printer stores the symbol data in the print buffer without executing actual printing.
■
The quiet zone is not included in the printing data. Be sure to include the adequate quiet zone for executing of this
command.
Differences: