ESC v
Function:
Transmit paper sensor status
Code:
ASCII
ESC
v
Hex
1B
76
Decimal
27
118
Range:
None
Default:
None
Description:
■
This command transmits a byte of data specifying the paper sensor status.
■
The status of paper end sensors is sent to the host as follows:
•
When paper end is detected, 0xC is transmitted.
Remarks:
■
The paper sensor status can be transmitted using GS r.
Differences: