Bitron Video AV1183 Series Instruction Manual Download Page 8

8

012175604.10

The dimensions of the reading window are 31 x 14 mm with 18 mm gap in between 

(Fig. 5)

.

To insert the printed name card, remove the entire block 

(Fig. 3) 

formed by a white plastic element and a 

transparent Plexiglas element, remove the protective fi lm from the latter, dispose of the white plastic element 
and position the printed name card behind the Plexiglas element, inserting it in its seat. Make sure the names 
are correctly centred in the reading window.

Close the module making sure that the slots on the upper part of the lid are inserted on the protrusion on the top 
of the module, push upwards, lower the lid and fasten the specifi c screw with the tool provided 

(Fig. 6 - 7)

Remember to check that the microphone hole on the bottom left is aligned with the hole on the module 
lid.

 

CONNECTION TERMINALS

CH

 

= Doorphone sensor and call

AP

 

= Electrical lock terminal (closed to ground)

D

 = 

Floor 

call

CP

  

= Button common (doorphone call)

~

 

= 12 Vac power from transformer 

0

 

= Power negative from transformer and system ground (to doorphones) 

CD

 

= Diode common to other rows or to relay box for special applications

X

 

= CD from relay box for one or more on-board buttons (after cutting sealed CD jumper) 

The correct connection of the two wires to the “0” terminal is crucial to prevent buzzing. 

 

CONNECTIONS

The following rules must be observed for connections:

  Respect the instructions shown in the table 

(Fig. 8)

 carefully. 

  Avoid installing system wires close to electrical mains wires (they should be at least 30 cm apart). 

  Connect the ground wires exactly as shown in 

Fig. 9 

to avoid buzzing.

Position the transformer at a maximum distance from the door panel of 20 metres. 
Use 1 mm

2

 wires for connecting terminals ~ and 0. Also respect the connections shown on the diagram 

to prevent noise.

 

VOLUME ADJUSTMENT

The entrance panel audio unit settings are optimal for a system of average size by default. 
The settings may however need to be changed.
Proceed as follows in such a case 

(Fig. 10)

  External volume: turn trimmer EXT clockwise to turn the volume up and anticlockwise to turn it down.

  Internal volume: turn trimmer INT in a similar way. 

Turn down both volumes slightly if feedback loop howl occurs to eliminate the problem. 

 

CALL CONFIRMATION EXCLUSION

The entrance panel generates a confi rmation tone when the doorphone call is sent to the doorphone. This tone 
may be deactivated by cutting the “RC” jumper near the entrance unit terminal board as shown in 

(Fig. 11)

.

012175604.10

9

 

ELECTRONIC DOORPHONE OR BUZZER CALL SELECTION

      CALL TYPE (E R)

This jumper is used to select the doorphone call type made by the audio unit when the button is pressed on 
the unit or panel. 
There are two possible modes 

(Fig. 12)

.

  ELECTRONIC (Default): When the jumper is positioned on the central pin and E (electronic).

  A tone suited to all new-generation doorphones will be generated in this confi guration.

  BUZZER when the jumper is positioned between central and R (buzzer). 

  In this confi guration, the unit will generate a tone adapted to all old model doorphones supporting 
  mechanical buzzer calls. A 100Hz tone will be generated.

 

CALL SHORT CIRCUIT PROTECTION

The protection system will cut off calls for a few seconds in the event of a calling terminal short circuit. After 
this time, the entrance panel will be able to generate a new call. The cycle will be repeated if the short circuit 
persists.

 

BUTTON COMMON (CP) AND DIODE COMMON (CD) CONNECTION

The buttons on the audio module are already connected to the button common and the diode common by 
means of two jumpers (CP and CD) selectable for special applications. Consequently, connect the users to 
terminals C1 user 1 and C2 user 2 for 1-2 button audio modules AV1183/001 - AV1183/002.
When using a 2 or 3 row PE, use a piece of wire to connect CP on the audio section (on the right of the module) 

(Fig. 9a)

 to CP of the adjacent button module on the bottom right and use another piece of wire to connect 

CD on the audio section terminal board to CD on the key module terminal board next to the CP terminal. Use 
the button terminals from C1 to C7 for audio and doorphone calls to each user: be careful not to connect the 
users on the right of the CP part because calls on the doorphones connected to the terminal will always be 
active.

 

Summary of Contents for AV1183 Series

Page 1: ...products Therefore Bitron Video reserves the right to introduce changes or modifications all its products in any moment and without prior notice Bitron Video applique une mèthode de dèveloppement continu Par conséquent Bitron Video se réserve le droit d apporter des changements et des améliorations à tout produt décrit dans ce document sans aucun préavis 012175604 10 MANUALE ISTRUZIONE CARATTERIST...

Page 2: ...07 004 AV 1407 002 AV 1209 007 AV 1183 002 AV 1183 002 AN 1299 12 0 Au Au 2 1 P 0 12 RETE MAINS AN 1299 C2 C1 X CH AP P CP 0 CD R65 E R JP3 RC R63 CD CP CP CP Au 2 1 P Au C2 C1 X CH AP P CP 0 CD R65 E R JP3 RC R63 CD CP CP CP C7 C6 CD CP 0 C1 C2 C3 C4 C5 CDS XS CI 1 CHP CP CII 2P 2S CHS CS 2 1P NA 3P 3S N 1S NC 3 0 LP T R PA PB CDP OCP OCS XP SA SB 9S 9P 9 PM TIMER AN 7775 DE 80 Au 2 1 P Au P 1 2 ...

Page 3: ...al piano Call button at the floor Touche d appel d etage Nella DE80 rimuovere il ponticello PM e regolare al minimo il trimmer del timer Remove the PM jumper on DE80 and adjust the time trimmer at the minimum Enlever le pontet PM dans le DE80 et regler le trimmer du temporisateur au minimum Nei posti esterni AV1183 002 interrompere il ponticello CD R63 On the door panel AV1183 002 remove bridge CD...

Page 4: ...lli al muro attraverso i fori posti sul dorso del modulo Fig 1 APERTURA ED INSERIMENTO CARTELLINO PORTANOME L accessibilità al cartellino portanome è ottenibile svitando la vite posta sul frontale Fig 7 del modulo utilizzando l apposito attrezzo in dotazione Successivamente sollevare il frontale dal modulo All interno del frontale sulla parte destra si troverà incastrato il cartellino portanome Sf...

Page 5: ...l appel activé en permanence 012175604 10 5 In ogni caso le dimensioni del cartellino pantografato possono essere principalmente due 36 x 40 x 2 mm nel caso del modulo con 1 2 Tasti ad una fila o nella prima fila nel caso dei moduli a 2 3 file 36 x 130 x 2 mm nel caso dei moduli a 2 3 file per i tasti posti sulla seconda e terza fila o per il modulo a singola fila 7 tasti Le dimensioni della fines...

Page 6: ...la première rangée dans la configuration avec des modules à 2 3 rangées 36 x 130 x 2 mm dans la configuration des modules à 2 3 rangées pour les touches situées sur la deuxième et troisième rangée pour le module doté d une rangée unique à 7 touches Les dimensions de la fenêtre de lecture correspondent toujours à 31 x 14 mm avec un écartement de 18 mm Fig 5 Pour introduire la plaquette gravée extra...

Page 7: ... gravée L épaisseur doit être identique à l élément en plastique blanc 2 mm en utilisant le feuillet en papier fourni de série comme étalon pour disposer correctement les noms Dans tous les cas les dimensions de la plaquette gravée doivent être fondamentalement deux 012175604 10 7 ENGLISH TECHNICAL SPECIFICATIONS Power 12 V ac Surface mounted dimensions 152 x 56 x 23 mm 1 row Surface mounted dimen...

Page 8: ...urn the volume up and anticlockwise to turn it down Internal volume turn trimmer INT in a similar way Turn down both volumes slightly if feedback loop howl occurs to eliminate the problem CALL CONFIRMATION EXCLUSION The entrance panel generates a confirmation tone when the doorphone call is sent to the doorphone This tone may be deactivated by cutting the RC jumper near the entrance unit terminal ...

Reviews: