background image

 

 

Appendix 1. 

BI 868 TREK parameters 

Name 

ID 

Capacity 

Possible values 

Units 

Default value 

Description 

Server 

ipsHost0 

245 

String 

IP или DNS 

No 

193.193.165.165 

Main server IP address 

ipsPort0 

246 

2 byte 

PORT 

No 

20127 

Main server PORT 

enaSecondHost 

196 

1 byte 

0-disabled; 1-enabled; 

No 

Reserve server enabling 

ipsHost1 

188 

String 

IP or DNS 

No 

193.193.165.165 

Reserve server IP address  

ipsPort1 

189 

2 byte 

PORT 

No 

20127 

Reserve server PORT  

ConfSenvEna 

908 

1 byte 

0-disabled; 1-enabled; 

No 

No 

Configuration server 

enabling 

settingsHOST 

220 

String 

IP or DNS 

No 

configurator.bitrek.com.ua 

WEB configurator IP address 

settingsPort 

221 

2 byte 

PORT 

No 

55755 

WEB configurator PORT 

settingsTimeOut 

222 

2 byte 

0 — 65535 

Sec. 

900 

WEB configurator 

connection period 

Connection 

APN 

242 

String 

APN 

No 

gps.utel.ua 

APN 

Usname 

243 

String 

User Name 

No 

none 

GPRS login 

Uspass 

244 

String 

User Pass 

No 

none 

GPRS password 

Tracking 

enTimePer 

900 

1 byte 

0-disabled; 1-enabled; 

No 

Tracking by time enabling 

enDistPer 

901 

1 byte 

0-disabled; 1-enabled; 

No 

Tracking by distance 

enabling 

enAngPer 

902 

1 byte 

0-disabled; 1-enabled; 

No 

Tracking by azimuth 

enabling 

nightPer 

11 

2 byte 

0 — 65535 

Sec. 

30 

Tracking period during 

ignition turned off 

dayPer 

903 

2 byte 

0 — 65535 

Sec. 

30 

Tracking period during 

ignition turned on 

Summary of Contents for BI 868 TREK

Page 1: ...ount 260075014037759 in UKREXIMBANK in Kyiv MFI 380333 tax number 163033726585 95 S Vidradniy avenue Kyiv Ukraine 03061 Phone 38044 507 02 07 Fax 38044 507 02 02 www bitrek eu sales bitrek eu USER MANUAL GPS TRACKER BI 868 TREK Version 2015 11 1 Kyiv 2015 ...

Page 2: ...roduction 3 2 Purpose 4 3 Appearance 5 4 Package contents 6 5 Technical characteristics 7 6 Pin assignment 8 7 Device configuration 9 8 LED description 14 9 Tracker installation 15 10 Important points during equipment configuration 16 11 Conclusion 17 Appendix 1 18 ...

Page 3: ...REK device tracker on further Here you will find information about the whole operation process of the tracker its technical characteristics first configuration and after sales service important points during equipment configuration We hope that you will be satisfied with the quality reliability and stability of not only the tracker BI 868 TREK but also you will become our regular partner with othe...

Page 4: ...y BI 868 TREK is using for Geographical coordinates speed and direction of movement definition Remote control of executive devices Voice connection Data transfer to server for the further processing by specialized software BI 868 TREK is recommended for monitoring Cars and minibuses Trucks Construction machinery Agricultural machinery Passenger transport Railway transport BI 868 TREK is not recomm...

Page 5: ...www bitrek eu support bitrek eu 380 44 507 02 07 3 Appearance Appearance of BI 868 TREK and antennas connectors is shown in figure 3 1 Picture 3 1 BI 868 TREK appearance ...

Page 6: ...eu support bitrek eu 380 44 507 02 07 4 Package contents BI 868 TREK has the following package contents GPS tracker for moving objects BI 868 TREK 1 pc Technical passport 1 pc Guarantee card 1 pc Packing box 1 pc ...

Page 7: ... GLONASS GALILEO BEIDOU Accelerometer Protected power circuit SIM cards 1 Digital inputs 1 Digital outputs 1 Analog inputs 2 Digital inputs voltage range from 0V to 40V Supply voltage 12 24V Typical current consumption 12V 60mA Maximum current consumption 12V 350mA Internal nonvolatile memory 2MB 65 000 records Built in battery 1 000mA Operating battery от 30 С до 80 С Dimensions W х L х H 90 х 58...

Page 8: ...TREK pin assignment Color Contact name Type of signal Contact purpose Red Vсс Power supply On board power supply nominal voltage 12 V or 24 V Black GND Power supply Common wire ground White An_in 1 Input Analog input Brown An_in 2 Input Analog input Blue Ignition Input Active digital input 1 Reserved for ignition signal Purple Out 1 Output Digital output ...

Page 9: ...ort microsoft com en us kb 318785 en us How to update Framework https www microsoft com en US download details aspx id 30653 How to update Framework on Windows XP https www microsoft com en US download details aspx id 17851 7 1 Tracker to PC connection To connect tracker to PC you need to have 12 24 V power source BITREK programmer USB UART 1 2 3 4 5 6 1 2 3 4 5 6 Picture 7 1 USB UART top view Pic...

Page 10: ... operating system will automatically install driver for programmer If the automatic driver installation has not occurred download it from the link http www ftdichip com Drivers VCP htm or from BITREKTM corporate websites www bitrek eu or www bitrek com ua 7 2 Remote tracker configuration For remote configuration you need to have a power source 12 24V and a GSM modem with an activated SIM card with...

Page 11: ...7 BITREK CONFIGURATOR instruments 1 Model selection of connected device Depending on the model different parameters and commands in configurator workspace are available Make sure that the selected model equals to the model of the connected tracker To determine the tracker model you can use getver command on Commands tab 2 Open file configuration 3 Save selected parameters in configuration file 1 2...

Page 12: ...available for viewing sending to the tracker and requesting from the tracker 8 Parameter sending requesting Allows to select one of two modes upload parameters to the tracker with the chosen values request tracker s settings and show them in interface Settings of this function don t influence on commands sending 9 Send via USB By pressing this button all marked parameters and commands will be sent...

Page 13: ...n icon with a built in help in which you can find answers to your questions about the hardware settings for this tab Picture 7 9 BITREK CONFIGURATOR built in help When reassembling the tracker battery should be placed between the connectors XP1 and XP2 The soft layer foam should be directed to the board ...

Page 14: ...ate the work of the device LED modes Red LED Green LED Lights constantly Connection to server is established and data is transferred Doesn t light No satellites Blinks 1 time in 0 5 seconds Connection is not active Blinks 1 time in 0 2 seconds Connection is not active modem in is a sleep mode Blinks 1 time in 2 seconds Satellites OK location identified ...

Page 15: ... the car dashboard During tracker installation GPS receiver must be on the top Power cables are conducted through technological apertures in the vehicle from the battery location to the place of the regular tracker installation Power cables are connecting to the respective terminals of the battery Tracker connection is making according to the picture 6 1 During the welding work in the vehicle be s...

Page 16: ... Not activated GPRS service on the SIM card 10 5 Sending incorrect commands via BITREK Configurator During trackers operation the following factors influence on its correct work 10 6 Incorrect or unqualified device installation 10 7 Tracker installation on inappropriate transport 10 8 Intentional or unintentional trackers jamming using FM transmitters and other similar equipment 10 9 Installation ...

Page 17: ...estions and you were able to solve the tasks in front of you If you have suggestions comments or any other questions about working with our equipment you can always appeal BITREKTM helpdesk in any convenient way Full list of contacts you can find at our official websites www bitrek eu or www bitrek com ua We are looking forward to your comments and suggestions that will help us get better every da...

Page 18: ... IP or DNS No configurator bitrek com ua WEB configurator IP address settingsPort 221 2 byte PORT No 55755 WEB configurator PORT settingsTimeOut 222 2 byte 0 65535 Sec 900 WEB configurator connection period Connection APN 242 String APN No gps utel ua APN Usname 243 String User Name No none GPRS login Uspass 244 String User Pass No none GPRS password Tracking enTimePer 900 1 byte 0 disabled 1 enab...

Page 19: ... accelerometer sendPer 270 2 byte 0 65535 Sec 35 Data transfer period sleepEna 911 1 byte 0 disabled 1 enabled No 0 Sleep mode by accelerometer enabling WEIT_SLEEP_TI MEOUT 4007 2 byte 0 65535 Min 12 Sleep mode by accelerometer turn on timeout SLEEP_TIMEOUT 4008 2 byte 0 65535 Min 15 Sleep mode by accelerometer timeout minGPSSpeed 918 1 byte from 1 to 256 km h 4 Minimum GPS speed for movement dete...

Page 20: ...ction level JammingEna 807 1 byte 0 disabled 1 enabled No 0 Jamming SMS enabling Roaming enaCops 917 1 byte 0 home network 1 roaming No 0 Tracker operating mode 0020 0059 String ххххх No Operators code list settings 0060 0099 String APN No Operators APN list settings 0100 0139 String No Operator GPRS login settings 0140 0179 String No Operator GPRS password settings rebootPer 186 1 byte from 1 to ...

Page 21: ...IO element ID sending SMS on authorized phone number trigger smsText 817 String text No Text added to SMS not more than 30 symbols Notifications dHigh1 Ignition 540 545 1 byte No Digital input with logic 1 AIN1 300 305 2 byte В Analog input 1 AIN2 310 315 2 byte В Analog input 1 PSV 410 415 2 byte В Board voltage VBAT 420 425 2 byte В Battery voltage GSMCSQ 470 475 1 byte No GSM level realOdometr ...

Page 22: ...us NetReg 760 765 1 byte 0 nor registered and not searching the network 1 registered in home network 2 not registered and searching the network 3 registration disabled 4 status N D 5 registered in roaming No GSM network registration status GPRSReg 770 775 1 byte 0 nor registered and not searching the network 1 registered in home network 2 not registered and searching the network 3 registration dis...

Page 23: ...ed 1 65535 Pcs 0 Records quantity in packet tryDataSendNum 356 1 byte from 1 to 256 Pcs 3 Sending data attempts quantity dataACKTM 357 2 byte 0 65535 Sec 10 Waiting time of server response connTryAm 904 1 byte from 1 to 256 Pcs 3 Sending data attempts quantity in series connTryInt 905 2 byte 0 65535 Sec 60 Waiting period between attempts in series connSerInt 906 2 byte 0 65535 Pcs 300 Waiting peri...

Reviews: