follows - lower limit of the range is recorded to the corresponding
parameter - "Lower limit", upper limit of the range is recorded to the
corresponding parameter "Upper limit"), the event will be generated
when the actual value of the sensor gets within the specified range. In
other cases, the event will not be created and the information will not be
sent to the server.
Example
: The lower voltage limit is set to 0, the upper limit is set to 10 V
(10 000 mV). Lowering the voltage below 10 V will generate the event
(see Figure 5).
PSV
U, mV
t, s
10 000
Figure 5 - Generation of event by returning to the range.
1 - Leaving the range.
The event will be generated if the actual sensor value is outside the
predetermined range.
Example: The lower voltage limit is set to 0, the upper limit is set to 10 V
(10 000 mV). Rising of the voltage above 10 V will generate the event
(see Figure 6).