background image

DYSCOVI SYSTEMS RPE LIMITED 

Company code 16303375, account №260075014037759 

In “UKREXIMBANK” in Kyiv 

MFI 380333, tax number 163033726585

  

 

www.bitrek.com.ua  
[email protected] 
+380 44 507 02 07

 

95-S Vidradniy avenue, Kyiv, Ukraine, 03061. Phone +38044 507 02 07. Fax +38044 507 02 02. www.bitrek.com.ua, [email protected] 

 

 

 

 

 

 

Vehicles Tracking Device 

 

BI-520L TREK 

 
 
 
 

 

 
 

 
 
 
 
 

Operating manual 

 
 
 
 
 
 
 
 
 
 
 

Version 2019.09.1 

Summary of Contents for BI-520L TREK

Page 1: ...in Kyiv MFI 380333 tax number 163033726585 www bitrek com ua sales bitrek com ua 380 44 507 02 07 95 S Vidradniy avenue Kyiv Ukraine 03061 Phone 38044 507 02 07 Fax 38044 507 02 02 www bitrek com ua sales bitrek com ua Vehicles Tracking Device BI 520L TREK Operating manual Version 2019 09 1 ...

Page 2: ... 6 SIM card installation 6 Connector for power supply and peripherals 7 Assembly commissioning 8 Assembly recommendations 8 Electrical connections 8 Device to computer connection 9 Description of indication elements 10 Adjustment of BI 520L TREK device 10 Basic information 10 List of information commands to operate the device 11 List of control commands to operate the device 14 Basic configuration...

Page 3: ...disconnecting the power socket and inputs outputs turn off the power supply Transportation and storage Transportation of tracking device in the transport packaging of the manufacturer is allowed by all kinds of enclosed land and sea transport rail cars containers vehicles of closed type bilges etc Transportation in pressurized heated compartments of the aircraft is allowed Transportation and stora...

Page 4: ...t Operation principles In real time mode the tracking device determines location and movement parameters of the object time geographical coordinates speed and direction collects and processes information from the analog digital and discrete sensors ensures control over actuating mechanisms upon command from the control dispatching panel Received data are recorded and stored in an internal log whic...

Page 5: ...celerometer 9 Number of discrete outputs 1 10 Type of power supply Direct current 11 Internal battery 130 mAh 12 Supply voltage From 6 V to 36 V 13 Average consumption current 12 V 40 mA 14 Type of discrete outputs Open collector 15 Maximum current of discrete outputs 0 5 А 16 Number of analog inputs 1 17 Range of voltage of analog inputs From 0 V to 27 V 18 Volume of nonvolatile memory 2 MB or 50...

Page 6: ...package The tracking device BI 520L TREK is provided with the following set 1 Tracking device BI 520L TREK 1 piece 2 Connection cable 1 piece 3 Technical datasheet 1 piece 4 Warranty card 1 piece 5 Package box 1 piece Preparation for operation commissioning SIM card installation To operate in GSM network device shall contain installed SIM card of Micro SIM format Phonebook of SIM card shall remain...

Page 7: ...the slot see Figure 2 Figure 2 Installation of SIM card into the device Connector for power supply and peripherals The rear panel of the tracking device contains a socket for cable connection Connecting cable in turn has outlets for power analog digital discrete sensors and actuating mechanisms Location and numbering of contacts are shown in Figure 3 Marking of connector pins for power supply sens...

Page 8: ... commissioning Assembly recommendations Zone of installation of tracking device shall enable the connecting of the pin to it and disable the possibility of accidental damage to the device moisture impact of high temperature Recommended location for installation in the vehicle is an empty space under the dashboard inside the vehicle in addition the device shall be placed in a way ensuring the upper...

Page 9: ...utputs via additional relay Analogue input voltage shall not exceed 27 V Device supply voltage shall not exceed 36 V Otherwise the device may be put out of action Device to computer connection The tracking device can be connected to a PC in order to configure the device as well as to perform maintenance works For this purpose the device is equipped with a service UART output To connect to a comput...

Page 10: ...cess to the device terminal default value is 11111 Lifetime of access password after sending is 60 seconds After this time re send the password to exchange data with the device Description of indication elements Top panel of the tracking device contains two LEDs that indicate the current status of the device LED STATUS red is on for 0 5 seconds and is off for 0 5 seconds when GPRS connection is in...

Page 11: ...of response 1 getstatus Information about current state of the device Yes 2 getgps Current GPS coordinates and time of device Yes 3 getmap Request of device coordinates Yes 4 getver Request of the version of the device software Yes 5 getio Read the value of the device s internal sensors Yes 6 flush Request of device profile parameters Yes 7 getparam Read the value of the parameter by its ID Yes No...

Page 12: ...ees Date current date 1980 1 6 is transmitted in the absence of GPS signal Time current GMT time 00 00 00 is transmitted in the absence of GPS signal Request of device coordinates Command to be sent getmap Example of response www biakom com maps q 50 420209 30 428448 12 0 Request of the version of the device software Command to be sent getver Example of response BI 520L Ver 0 9 1 Read the values o...

Page 13: ...ator usually not required IP xxx xxx xxx xxx Server IP address for data transmission PORT xxxxx PORT of server for data transmission MODE 0 mode of device operation 0 TCP IP connection Read the value of the parameter by its ID Command to be sent getparam Parameter ID consists of four digits and indicates the number of the parameter All configurable parameters are specified in the list of device pa...

Page 14: ...of ignition Yes Notes to Table 4 Reboot of device processor Command to be sent cpureset No response is returned for this command Receipt of the command initiates a complete restart of all device processes Restoring of original state of profile settings Command to be sent rstallprof No response is returned for this command Receipt of this command initiates reset of profile parameters to default one...

Page 15: ...Note Enable download for the SIM card and set the session timeout not less than 10 seconds There are following responses at attempt to update the device software BOOT UPDATE DOWNLOAD OK successful update BOOT WAITE ERROR exceeded timeout at downloading software update BOOT HOST CONNECT ERROR failure to connect to server with SW BOOT PAGE LOAD ERROR failure to load the file BOOT UPDATE DOWNLOAD ERR...

Page 16: ...rrent location to the server All parameters available for configuration are specified in Appendix 1 Security settings To meet the safety conditions access to the configuration of the device can be limited At connection your device to the PC using USB UART converter every time you send a command the device requires the access password Standard access code is 11111 Lifetime of password is 60 seconds...

Page 17: ...ed in each SMS with commands Adjustment of I O elements The tracking device BI 520L TREK is able to collect process and send to the server the data received from various sensors Each sensor is an I O element and has a group consisting of 6 parameters for setting For example to set the value of power supply voltage level to the server use group of parameters of ID 0410 0411 0412 0413 0414 0415 Thes...

Page 18: ...nt to change the input value to a predetermined value 8 generation of the event to change the input value to a predetermined value monitoring 5 Averaging constant From 0 and higher Notes to Table 5 Parameter 0 on off of transmission of I O element to the server Parameter 1 Priority low high While selecting Priority low data of the sensor will be sent to the server with the following data packet Wh...

Page 19: ... be created and the information will not be sent to the server Example The lower voltage limit is set to 0 the upper limit is set to 10 V 10 000 mV Lowering the voltage below 10 V will generate the event see Figure 5 PSV U mV t s 10 000 Figure 5 Generation of event by returning to the range 1 Leaving the range The event will be generated if the actual sensor value is outside the predetermined rang...

Page 20: ...ge crosses limits of the specified range then event is generated see Figure 7 PSV U mV t s 10 000 5 000 Figure 7 Generation of event by returning leaving to of the range 3 Monitoring When this mode is selected data will be transmitted continuously the events will not be generated 4 Monitoring entering the range When there is generated the event after entering the range the actual value of the sens...

Page 21: ...l at occurrence of certain conditions Such a condition is a triggering of predetermined I O element Voice calls shall be enabled in the general settings of the device I O element shall be enabled configured for one of the events entry to the range exit out of the range entry exit in out of the range its ID shall be defined as a trigger of outgoing call Phone0 authorized phone number shall be defin...

Page 22: ...vice checks the list of approved operators If the list is empty the device acts like in a mode of operation in a home network If the list is not empty the device scans for available networks If there are any networks included in the list of authorized ones the device makes an attempt to register in one of the authorized networks After successful registration the device will be connected to the sel...

Page 23: ...er 1111 ipsHost1 0188 string IP address of backup server 193 193 165 165 ipsPort1 0189 2 byte PORT of backup server 20127 ConfServEna 0908 1 byte Operation with the configuration server 0 disabled 1 enabled 1 settingsHost 0220 string IP or DNS of WEB configuration server configurator bitrek com ua settingsPort 0221 2 byte PORT of WEB configuration server 55755 settingsTimeOut 0222 2 byte Period of...

Page 24: ...cond 300 Switching Host 2 Port 2 0196 1 byte Permission to use backup server 0 ProtocolType 0241 1 byte Type of data transfer protocol to the server 0 Teltonika 1 IPS 0 GPRSReg Timeout 4018 2 byte GPRS network registration timeout second 120 GSMReg Timeout 4019 2 byte GSM network registration timeout second 120 Tracking Enable Time Period 0900 1 byte Permission to record by time 1 Enable Dist Peri...

Page 25: ...a response from the server second 10 Delta X 0281 1 byte Angle of deviation of the accelerometer by X axis degree 3 Delta Y 0282 1 byte Angle of deviation of the accelerometer by Y axis degree 3 Delta Z 028З 1 byte Angle of deviation of the accelerometer by Z axis degree 3 Start Move Timeout 0284 2 byte Timeout of movement start according to the accelerometer 0 1 sec 50 Stop Move Timeout 0285 2 by...

Page 26: ...ber 0 Phone1 0262 string Authorized telephone number 1 Phone2 0263 string Authorized telephone number 2 Phone3 0264 string Authorized telephone number 3 Phone4 0265 string Authorized telephone number 4 Phone5 0266 string Authorized telephone number 5 Phone6 0267 string Authorized telephone number 6 Phone7 0268 string Authorized telephone number 7 Phone8 0269 string Authorized telephone number 8 SM...

Page 27: ... 0 disabled 1 enabled 0 Service Reboot Per 0186 1 byte Period of the regular reboot of the device hour 24 Reboot Type 0187 1 byte Type of device reset 0 full 1 only modem 0 ErrSatNum 0992 1 byte Authorization to set the number of satellites at the loss of GPS signal pcs 0 ringNum 0912 1 byte Number of rings before automatic response to check the SIM card pcs 3 NTP_Ena 0909 1 byte Time synchronizat...

Page 28: ...han 30 characters in the Latin alphabet Roaming Operator selection 0917 1 byte Operator selection mode 0 UsipTable 0020 0059 string List of codes of authorized operators UsAPNTable 0060 0099 string List of APN of authorized operators UsLoginTable 0100 0139 string List of GPRS logins of authorized operators UsPassTable 0140 0179 string List of GPRS passwords of authorized operators Parameters for I...

Page 29: ...etected by GPS more than 10 km h speed detected over 10 sec 3 motion detected by accelerometer and GPS 6 realOdometr 199 0500 0501 0502 0503 0504 0505 Relative odometer 7 Odometr 200 0710 0711 0712 0713 0714 0715 Absolute odometer 8 GPSPower 69 0450 0451 0452 0453 0454 0455 Availability of GPS signal 9 GSMCSQ 21 0470 0471 0472 0473 0474 0475 Level of GSM signal 10 OperCode 111 0680 0681 0682 0683 ...

Page 30: ...975 Value of acceleration of braking 24 ecoCrn 47 5450 5451 5452 5453 5454 5455 Value of corner acceleration 25 HDOP 122 0800 0801 0802 0803 0804 0805 Reduced accuracy in the horizontal plane 26 iMCC mcc 4010 4011 4012 4013 4014 4015 Positioning by base stations 27 iMNC mnc 4020 4021 4022 4023 4024 4025 Positioning by base stations 28 iLAC lac 4030 4031 4032 4033 4034 4035 Positioning by base stat...

Page 31: ...7 2018 Ver 2018 07 2 Added new I O elements IDsend 46 and IDsend 47 Added time synchronization via NTP IDconf 0909 09 10 2018 Ver 2018 10 1 Added new I O element IDconf 0907 11 01 2019 Ver 2019 01 1 Added detailed description of the parameter ID_Send 240 21 02 2019 Ver 2019 02 1 Added detailed description of id_Send parameters 44 45 47 05 09 2019 Ver 2019 09 1 Added description of parameters ID_Co...

Reviews: