background image

 

R4 

Server

 Manual

Last updated: 8/30/2016 

Page 

2

 of 1

1

Page 2 / 1

1

 

Contents 

Overview ................................................................................................................................... 3 

Features ..................................................................................................................................... 3 

Power Supply............................................................................................................................. 4 

Connect to 

Server

 ...................................................................................................................... 5

Server

 Configuration .................................................................................................................. 7

5.1 

Pool Setting ................................................................................................................... 7 

5.2 

Frequency Modification ................................................................................................ 8 

Server

 Status .............................................................................................................................. 8

System Configuration and status ............................................................................................... 9 
7.1 

System Upgrading ......................................................................................................... 9 

7.2 

Password Modification ................................................................................................ 10 

7.3 

Software Version Checking .......................................................................................... 10 

7.4 

Restore Initial Setting .................................................................................................. 10 

Summary of Contents for R4

Page 1: ...BITMAIN R4 Server Manual ...

Page 2: ...atures 3 3 Power Supply 4 4 Connect to Server 5 5 Server Configuration 7 5 1 Pool Setting 7 5 2 Frequency Modification 8 6 Server Status 8 7 System Configuration and status 9 7 1 System Upgrading 9 7 2 Password Modification 10 7 3 Software Version Checking 10 7 4 Restore Initial Setting 10 ...

Page 3: ... prepare your own ATX Power Supply 2 Features Ideal Hash Rate GH s 8 6TH S 5 Default chip clock M 600 Input Voltage V 11 6 13 00 Estimate power on wall W assume with APW3 93 efficiency 25 ambient temp 845W 9 Estimate efficiency on wall J GH 0 1J GH 9 Dimensions mm 515 100 222 Net Weight kg 5 Operating ambient temperature C 0 40 Noise 52dB ambient temperature of 35 Networking connection mode Ethern...

Page 4: ...r all the 7 PCI e connectors are required Do not connect more than one PSU to the same hash board to prevent possible damage and instability After connecting all the hash boards and the controller to PSU and the wire cable to the ETHERNET port you can start the server See the screen shot below for the CORRECT and INCORRECT connection of the PCI E connectors Correct connection Incorrect connection ...

Page 5: ...supported by Windows then please follow the below steps to find out the IP of the server 1 Extract the file and double click IPReporter exe The Shelf Step Position options are suitable for farm servers to mark the location of the servers For home servers it can be left as default Then click Start 2 Press the IP Reporter button on the controller board for about 5 seconds and you ll hear a beep soun...

Page 6: ... ll see the IP address showing in the pop up window Step 2 Enter the IP address provided into your WEB browser and proceed to login using root for both the username and password In the Network section you can assign a Static IP address if you like Click Save Apply after modifying it ...

Page 7: ...if all higher priority pools have gone offline 5 1 2 When Stop running when temperature is over 80 is checked the server will stop mining when the temperature PCB exceeds 90 to protect the server If it is unchecked the server will still mine even at high temperatures Note that while the interface says 80 the PCB temperature will actually go to 90 before the machine stops mining 5 1 3 When Customiz...

Page 8: ...cy for the R4 server is 600M 6 Server Status You can check the operating status of your server on the page below ASIC Number of chips detected in the chain Frequency ASIC frequency setting GH S RT Hash rate of each hash board Temp PCB Temperature of the hash board centigrade Temp Chip Temperature of the chips on the hash board centigrade ASIC status o denotes OK x denotes error denotes dead ...

Page 9: ...wse button to choose upgrade file Select the upgrade and click the Flash image button The interface will display if the firmware can be upgraded and download the software During the upgrade process you need to wait patiently and must keep power on otherwise the server can only be fixed with returned to factory You will see below screenshot after upgrading successfully Clicking the Reboot button wi...

Page 10: ...System Overview page File System version displays the date of the firmware your server use In the example below the server is using 20160527 firmware 7 4 Restore Initial Setting There is a Reset button on the right hand side of the ETH port next to the green and red LED light Power on server and let it run for 5 minutes then press and hold the reset button for 10 seconds in order to restore to the...

Page 11: ...Page 11 11 R4 Server Manual Last updated 8 30 2016 Page 11 of 11 ...

Reviews: