background image

- 18 -

T19 Server Installation Guide 

Regulations: 

FCC Notice (FOR FCC CERTIFIED MODELS): 

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause 

harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired 
operation. 

Note:

 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. 

These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a 
commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in 
accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a 
residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own 

expense. 

EU WEEE: Disposal of Waste Equipment by Users in Private Household in the European Union 

This symbol on the product or on its packaging indicates that this product must not be disposed of with your other 
household waste. Instead, it is your responsibility to dispose of your waste equipment by handling it over to a 
designated collection point for the recycling of waste electrical and electronic equipment. The separate collection 
and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure 

that it is recycled in a manner that protects human health and the environment. For more information about where 
you can drop off your waste equipment for recycling, please contact your local city office, your household waste 

disposal service or the shop where your purchased the product. 

台湾

ROHS: 

設備名稱:

T19    

服務器型號:

240-Ca 

單元

有害物質

(Pb) 

Hg

 

Cd

 

六價鉻

(Cr+6) 

多溴聯苯

PBB

 

多溴二苯醚

PBDE

 

外殼

電路板組件

其他線材

備考

1.

〝超出

0.1 wt %

〞及〝超出

0.01 wt %

〞係指限用物質之百分比含量超出百分比含量基準

 

值。
備考

2.

〝○〞係指該項限用物質之百分比含量未超出百分比含量基準值。

 

備考

3.

〝-〞係指該項限用物質為排除項目。

 

Summary of Contents for ANTMINER 240-Ca

Page 1: ...ations using Bitmain components To minimize the risks associated with customer products and applications customers should provide adequate design and operating safeguards Bitmain does not warrant or represent that any license either express or implied is granted under any Bitmain patent right copyright or other Bitmain intellectual property right relating to any combination machine or process in w...

Page 2: ...of Bitmain Information in this document is subject to change without notice and does not represent a commitment on the part of Bitmain Although the information in this document has been carefully reviewed Bitmain does not warrant it to be free of errors or omissions Bitmain reserves the right to make corrections updates revisions or changes to the information in this document Bitmaintech Pte Ltd T...

Page 3: ...ifications 7 2 Setting Up the Server 9 3 Configuring the Server 12 4 Monitoring Your Server 13 5 Administering Your Server 14 5 1 Checking Your Firmware Version 14 5 2 Upgrading Your System 14 5 3 Modifying Your Password 15 5 4 Restoring Initial Settings 15 Environmental Requirements 16 Regulations 18 ...

Page 4: ...ew Caution 1 The equipment must be connected to an earthed mains socket outlet The socket outlet shall be installed near the equipment and shall be easily accessible 2 The equipment has two power inputs only by connecting those two power supply sockets simultaneously can the equipment run When the equipment is powered off be sure to power off all power inputs 3 DO NOT remove any screws and cables ...

Page 5: ... 5 T19 Server Installation Guide 1 Overview 1 1 T19 Server Components The main components and controller front panel of T19 servers are shown in the following figure ...

Page 6: ...Server Installation Guide 1 Overview APW12 Power Supply Note 1 Power supply APW12 is part of T19 server For detailed parameters please refer to the specifications below 2 Additional two power cords are needed ...

Page 7: ...oltage Volt 1 1 200 240 Power supply AC Input Frequency Range Hz 47 63 Power supply AC Input current Amp 1 2 20 1 3 Hardware Configuration Network connection mode RJ45 Ethernet 10 100M Server Size Length Width Height w o package mm 2 1 400 195 5 290 Server Size Length Width Height with package mm 570 316 430 Net weight kg 2 2 14 2 Gross weight kg 16 Environment Requirements Operation temperature C...

Page 8: ...bly cause server damaged 1 2 Max condition temperature 40 C altitude 0m 1 3 Two AC input wires 10A per wire 2 1 Including PSU size 2 2 Including PSU weight 3 1 When the server is used at an altitude from 900m to 2000m the highest operating temperature decreases by 1 for every increase of 300m ...

Page 9: ...the following file IPReporter zip 3 Extract the file 4 Right click IPReporter exe and run it as Administrator 5 Select one of the following options Shelf Step Position suitable for farm servers to mark the location of the servers Default suitable for home servers 6 Click Start The file IPReporter zip is supported by Microsoft Windows only The default DHCP network protocol distributes IP addresses ...

Page 10: ...ndow on your computer screen 7 In your web browser enter the IP address provided 8 Proceed to login using root for both the username and password 9 In the Protocol section you can assign a Static IP address optional 10 Enter the IP address Subnet mask gateway and DNS Server 11 Click Save 12 Click https support bitmain com hc en us articles 360018950053 to learn more about gateway and DNS Server ...

Page 11: ... 11 T19 Server Installation Guide 2 Setting Up the Server ...

Page 12: ... Sleep mode The server enters the sleep mode under the condition that the control board is powered while hashboards are not powered 2 Set the options according to the following table Option Description Mining address Enter the address of your desired pool The T19 servers can be set up with three mining pools with decreasing priority from the first pool pool 1 to the third pool pool 3 The pools wit...

Page 13: ...own on the bottom of kernel log page Meanwhile the server temperature on the dashboard interface turns to abnormal and shows Temp is too high 2 Monitor your server according to the descriptions in the following table Option Description Number of chips Number of chips detected in the chain Frequency ASIC frequency setting Real Hashrate Real time Hashrate of each hash board GH s Inlet Temp Temperatu...

Page 14: ...on on the bottom 2 Firmware Version displays the date of the firmware your server uses In the examples below the server is using firmware version 20200601 5 2 Upgrading Your System Make sure that the T19 server remains powered during the upgrade process If power fails before the upgrade is completed you will need to return it to Bitmain for repair To upgrade the server s firmware 1 In System click...

Page 15: ...the server and it will turn to the setting page 5 3 Modifying Your Password To change your login password 1 In System click the Password tab 2 Set your new password then click Save 5 4 Restoring Initial Settings To restore your initial settings 1 Turn on the server and let it run for 5 minutes 2 On the controller front panel press and hold the Reset button for 10 seconds Resetting your server will...

Page 16: ...le the site should be chosen in the perennial upwind direction of the pollution source Please do not set your location within 3 7km from the seaside or the salt lake If unavoidable it should be built as airtight as possible equipped with air conditioning for cooling 1 3 Electromagnetic Environmental Conditions Please keep your site away from transformers high voltage cables transmission lines and ...

Page 17: ...rements of Corrosive Gas Corrosive Gas Unit Concentration H2S ppb 3 SO2 ppb 10 Cl2 ppb 1 NO2 ppb 50 HF ppb 1 NH3 ppb 500 O3 ppb 2 Note ppb part per billion refers to the unit of concentration 1ppb stands for the volume ratio of part per billion ...

Page 18: ...rence in which case the user will be required to correct the interference at his own expense EU WEEE Disposal of Waste Equipment by Users in Private Household in the European Union This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste Instead it is your responsibility to dispose of your waste equipment by handling it over...

Reviews: