BISWIND BWFAN01-Bronze Instruction Manual Download Page 25

  

 

Seite 

25

 von 

25

 

 

  

  

  

Informations techniques 

 

Tension nominale 

 

220-240V  

Fréquence 

 

50 Hz  

Puissance d’entrée nominale 

 

45W  

Hauteur 

 

121 cm  

Poids 

 

3.75 kg  

Nom  

 

Symbole  

Valeur  

Unité  

Débit volumique maximal 

 

F  

43,2  

m³/min  

Consommation électrique du ventilateur 

 

P  

64,8  

W  

Valeur du service 

 

SV  

0,66  

(m³/min)/W  

Niveau de puissance sonore du ventilateur 

  LWA  

64,6  

dB (A)  

Consommation en mode veille 

 

PSB  

0,227  

W  

 

 

Adresse  de  contact  pour  toute  information 
complémentaire et ligne de service : 

 

 

 

 

 

Schuss Home Electronic GmbH 

 

Scheringgasse 3, A-1140 Vienne 

 

Tel : +43 (1) 97 0 21 

– 0 

 

Ligne de service : +43 (1) 97 0 21 

– 502 

 

www.biswind.at

 

 

Registre du commerce n°: 236 974 t / 

 

Tribunal du registre du commerce : Vienne 

 

 

 

Summary of Contents for BWFAN01-Bronze

Page 1: ...RZLICHEN GL CKWUNSCH VIELEN DANK DASS SIE SICH F R EIN PRODUKT VON BISWIND ENTSCHIEDEN HABEN Diese Bedienungsanleitung gibt es in folgenden Sprachen Deutsch 2 9 English 10 17 Fran ais 18 25 Inhaltsver...

Page 2: ...digt ist Im Zweifelsfall verwenden Sie das Ger t nicht und kontaktieren die Servicestelle oder Ihren H ndler 3 Halten Sie Kinder von Verpackungsmaterialien fern Beim Verschlucken besteht Erstickungsge...

Page 3: ...B in feuchten Kellern neben Schwimmbecken Badewannen oder Duschen Achten Sie darauf dass kein Wasser in das Ger t eindringt 19 Stellen Sie keine Gegenst nde auf das Ger t 20 Stellen Sie das Ger t auf...

Page 4: ...ragen Sie zum Schutz der Ressourcen und der Umwelt bei F r weitere Information wenden Sie sich bitte an Ihren H ndler oder die rtlichen Beh rden KONFORMIT TSERKL RUNG Hiermit best tigen wir dass diese...

Page 5: ...Seite 5 von 25 MONTAGE...

Page 6: ...nung als auch direkt am Ger t mit den Tasten des Bedienfeldes eingestellt werden 4 Bei Steuerung mittels Fernbedienung ist diese direkt auf das Ger t zu richten damit eine einwandfreie Funktion gew hr...

Page 7: ...gew nschte Modus auf dem Display aufleuchtet Modus Funktion Natur Modus Wechselnde Geschwindigkeitsstufen welche den nat rlichen Wind nachempfunden wird Schlaf Modus Der Turmventilator verringert all...

Page 8: ...odus Das Display verdunkelt sich 30 Sekunden nach jeder Einstellung und leuchtet wieder hell auf sobald Sie die Fernbedienung oder das Bedienpanel bet tigen REINGUNGSHINWEISE Achtung Lassen Sie das Ge...

Page 9: ...ximaler Volumenstrom F 43 2 m min Ventilator Leistungsaufnahme P 64 8 W Serviceverh ltnis SV 0 66 m min W Ventilator Schallleistungspegel LWA 0 227 dB A Kontaktadressen f r weitere Informationen und S...

Page 10: ...y from packaging materials There is a risk of choking if swallowed 4 If the power cable is damaged it must be replaced by the manufacturer or an authorised service point in order to avoid all potentia...

Page 11: ...off before pulling the power plug 24 Do not pull on the power cable to unplug the device Always pull on the plug to unplug the device 25 Do not touch the plug with wet hands to avoid electrical shocks...

Page 12: ...ations and directives of the EU You can view the detailed Declaration of Conformity by clicking on the following link www biswind at downloads doc bwfan01 bronze pdf Subject to errors and technical ch...

Page 13: ...Seite 13 von 25 ASSEMBLY...

Page 14: ...th the buttons on the control panel 4 If controlled by remote control it should be aimed directly at the device to ensure proper operation REMOTE CONTROL CONTROL PANEL 5 When setting the functions the...

Page 15: ...up on the display Mode Function Nature Mode Changing speed levels which is modeled on the natural wind Sleep Mode The tower fan will decrease the speed every 30 minutes until it runs at the lowest spe...

Page 16: ...n of the air NOTE The tower fan has an automatic energy saving mode The display dims 30 seconds after each setting and lights up brightly when you press the remote control or control panel CLEANING IN...

Page 17: ...Fan power consumption P 64 8 W Service value SV 0 66 m min W Fan sound power level LWA 64 6 dB A Consumption in standby mode PSB 0 227 W Contact address for further information and service line Schuss...

Page 18: ...e doute ne pas utiliser l appareil et contacter le point de service ou votre revendeur 3 Tenez les enfants loign s des l ments d emballage Il y a un risque d touffement en cas d ingestion 4 Si le c bl...

Page 19: ...forte humidit par exemple dans des caves humides proximit de piscines de baignoires ou de douches Assurez vous que l eau ne peut pas p n trer dans l appareil 19 Ne placez AUCUN objet sur l appareil 20...

Page 20: ...ues Vous contribuerez ainsi la protection des ressources et de l environnement Pour plus d informations veuillez contacter votre revendeur ou les autorit s locales D CLARATION DE CONFORMIT Nous confir...

Page 21: ...Seite 21 von 25 ASSEMBLAGE...

Page 22: ...es boutons du panneau de commande 4 Si l appareil est command par une t l commande celle ci doit tre dirig e directement vers l appareil pour en assurer le bon fonctionnement T L COMMANDE PANNEAU DE C...

Page 23: ...allume sur l cran Mode Fonction Mode Nature Modification des niveaux de vitesse qui est calqu e sur le vent naturel Mode veille Le ventilateur tour diminuera sa vitesse toutes les 30 minutes jusqu ce...

Page 24: ...pose d un mode automatique d conomie d nergie L cran s assombrit 30 secondes apr s chaque r glage et s claire lorsque vous appuyez sur la t l commande ou le panneau de commande INSTRUCTIONS DE NETTOYA...

Page 25: ...u ventilateur P 64 8 W Valeur du service SV 0 66 m min W Niveau de puissance sonore du ventilateur LWA 64 6 dB A Consommation en mode veille PSB 0 227 W Adresse de contact pour toute information compl...

Reviews: