Clean the Pre-Motor Filter
www.BISSELL.com
8
1
2
3
4
Return tank back
on vacuum and
press firmly until
you hear “click.”
Remove Foam Filter from lid. Hand
wash in warm water and rinse well; mild
detergent may be used if desired.
Unplug vacuum, turn over and unscrew
six (6) Philips-head screws to remove
the bottom cover. Lift brush straight out.
Clean debris from Brush Roll. Inspect by
placing on its end and spin. The brush
roll should spin freely, multiple times by
one flick. If it doesn’t, replace Brush Roll.
Check Belt for wear or cuts and replace
if necessary.
Replace the Brush Roll and Belt by looping the Belt over the motor shaft and the
Brush Roll. Line up the end caps and pull the brush forward into place. This will
stretch the Belt. Return bottom cover back on and replace the screws.
End Cap
Belt
Replace Brush & Belt
Twist gray collar
counter clockwise,
until slot appears,
then separate
faceplate.
www.BISSELL.com
9
1
2
3
click
Maintain the TurboEraser® Tool
Remove Brush Roll,
Belt, and Paddle
Wheel. Inspect
for damages and
replace if necessary.
To reassemble, align two clips on each
end of Paddle Wheel with Belt on
and pop back into place. Place Brush
Roll with belt back in. Faceplate will
not close properly if all parts are not
aligned correctly.
Press the tank release button and pull
out to remove Dirt Tank.
1
2
3
Allow filter to air dry completely before
placing back into the tank lid.
Clearing a Clog
Remove the Stretch
Hose from the back
of the vacuum by
twisting it to the left.
Remove any debris
that may have gotten
clogged.
Check the Foot Hose on
the back of your vacuum
down towards the bottom.
If necessary, remove the
screw from the foot hose
and check for clogs.
Check the air passageway on
the bottom of your vacuum.
Remove the bottom cover and
the brush. Remove any debris.
1
2
3
WARNING
To reduce the risk of electric shock, turn power switch off and disconnect plug from
electrical outlet before performing maintenance or troubleshooting checks.
WARNING
Do not operate vacuum with damp or wet filters or without all filters in place.
WARNING
To reduce the risk of electric shock, turn power switch off and disconnect plug from
electrical outlet before performing maintenance or troubleshooting checks.