Clean the Pre-Motor Filter

www.BISSELL.com

8

1

2

3

4

Return tank back 

on vacuum and 

press firmly until 

you hear “click.”

Remove Foam Filter from lid. Hand 

wash in warm water and rinse well; mild 

detergent may be used if desired.

Unplug vacuum, turn over and unscrew 

six (6) Philips-head screws to remove 

the bottom cover. Lift brush straight out.

Clean debris from Brush Roll. Inspect by 

placing on its end and spin. The brush 

roll should spin freely, multiple times by 

one flick. If it doesn’t, replace Brush Roll. 

Check Belt for wear or cuts and replace 

if necessary.

Replace the Brush Roll and Belt by looping the Belt over the motor shaft and the 

Brush Roll. Line up the end caps and pull the brush forward into place. This will 

stretch the Belt. Return bottom cover back on and replace the screws.

End Cap

Belt

Replace Brush & Belt

Twist gray collar  

counter clockwise, 

until slot appears, 

then separate 

faceplate. 

www.BISSELL.com

9

1

2

3

click

Maintain the TurboEraser® Tool

Remove Brush Roll, 

Belt, and Paddle 

Wheel. Inspect 

for damages and 

replace if necessary.

To reassemble, align two clips on each 

end of Paddle Wheel with Belt on 

and pop back into place. Place Brush 

Roll with belt back in. Faceplate will 

not close properly if all parts are not 

aligned correctly.

Press the tank release button and pull 

out to remove Dirt Tank.

1

2

3

Allow filter to air dry completely before 

placing back into the tank lid.

Clearing a Clog

Remove the Stretch 

Hose from the back 

of the vacuum by 

twisting it to the left. 

Remove any debris 

that may have gotten 

clogged.

Check the Foot Hose on 

the back of your vacuum 

down towards the bottom. 

If necessary, remove the 

screw from the foot hose 

and check for clogs.

Check the air passageway on 

the bottom of your vacuum. 

Remove the bottom cover and 

the brush. Remove any debris.

1

2

3

WARNING

To reduce the risk of electric shock, turn power switch off and disconnect plug from 

electrical outlet before performing maintenance or troubleshooting checks.

WARNING

Do not operate vacuum with damp or wet filters or without all filters in place.

WARNING

To reduce the risk of electric shock, turn power switch off and disconnect plug from 

electrical outlet before performing maintenance or troubleshooting checks.

Summary of Contents for CLEANVIEW 2258 Series

Page 1: ...CLEANVIEW SWIVEL REWIND PET DELUXE ___________ USER GUIDE 2258 SERIES More of a video person Look for this icon and go online for an instructional how to video at www BISSELL com...

Page 2: ...necting or disconnecting the Pet TurboEraser Tool READ ALL INSTRUCTIONS BEFORE USING YOUR UPRIGHT VACUUM Always connect to a polarized outlet one slot is wider than the other Unplug from outlet when n...

Page 3: ...ension Wand Crevice Tool stores inside Now put your accessory tools on the vacuum and you re ready to go Pet Hair Eraser Tool 1 Place the Upper Handle onto the base and push it down Then attach the ha...

Page 4: ...o reduce the risk of electric shock turn power switch off and disconnect polarized plug from electrical outlet before performing maintenance or troubleshooting checks Press the tank release button and...

Page 5: ...for damages and replace if necessary To reassemble align two clips on each end of Paddle Wheel with Belt on and pop back into place Place Brush Roll with belt back in Faceplate will not close properl...

Page 6: ...garding this warranty or have questions regarding what it may cover please contact BISSELL Consumer Care by E mail telephone or regular mail as described below Limited Four Year Warranty Subject to th...

Page 7: ...f a warranty claim See the Warranty page for details BISSELL Rewards Points Automatically earn points for discounts and free shipping on future purchases Faster Service Supplying your information now...

Reviews: