2. Check whether the function of the pressure switch is normal and set the pressure
to 0.8mpa every week.
3. Clean the filter element in the filter every week.
Monthly maintenance
1. Apply soapy water to all joints to check the ventilation system for air leakage.
If there is any obvious air leakage, tighten the joints.
2. Check that all nuts and screws are fastened.
3. Replace the filter element of the filter.
4. Clean external parts of air compressor.
Quarterly maintenan ce:
1. Replace the piston for every 2000 hours of operation or 6 months.
2. Check whether the cylinder and piston are worn.
Troubleshootin
g
Fault
phenomeno n
fault caus e
solution
Spinning slo w
1. The voltage is too lo w
2. The extension line is too
long and too thin
3. Motor failur e
1. Please ask the power
company for maintena nce
2. Switch to thicker, shorter wi res
3. To send to maintenan ce